FBR variant_2

FBR menghadirkan pembakar gas industri low NOx dengan FGR (Flue Gas Recirculation) seri XP60 - P100 - P150/M-LX-FGR-EL yang dirancang untuk aplikasi ketel uap dan pemanas industri. Pembakar ini mendukung…

SKU 3G-FBR-00416

Juga terdaftar sebagai: 00240641 · 002406 41 · 002406-41

Merek
FBR
Item
variant_2
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
52 kg
stage
2 stages sliding or modulating
fuel type
Gas low nox
nozzle mm
250
fan motor w
1.5
power kw max
1450
power kw min
280
ip protection
IP 54
noisiness dba
81-82
gas consumption
20.1/58.3-116.7
electrical supply
3
power supply info
3~400V, 1/N~230V-50Hz
current absorption a
3.6
thermal power mcal h
172/500-1000
nominal electric power w
1.7
max combustion air temp c
60

Konten Lembar Data

GAS BURNERS MODULATING LOW NOx WITH FGR GAS BURNERS MODULATING LOW NOX WITH FGR SK073014_C_en GAS XP60 - P100 - P150/M-LX-FGR-EL Burners for gas modulating (PID fully modulating) equipped with electronic control box LAMTEC BT3. They are composed by: die-cast aluminum body, fan at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Gas train completely assembled and tested; complete of working valve with flow adjustment, safety valve, minimum gas pressure switch and gas filter. Complete of flange and gasket for installation on generator. The actuators are independent and are managed directly by the electronic cam: - one actuator for the gas modulator - one actuator for the air shutter - one actuator for the FGR shutter The burners are equipped with an operating display that allows: - Adjustment of the parameters of the burner operation - Adjustment of the setpoint and operation range of the pressure / temperature probe - Adjustment of the burner's curveset With the addition of optional accessories (probes) thanks to the most advanced systems for automatic modulation in mechanical or electronic version, the burner constantly ensures the proper gas / air ratio. The maximum efficiency of the returns in each combustion point derived from the punctual adaptation of the thermal load to the heat requirements of the burner at any instant of operation. In the version with the electronic cam the fuel / combustion air curve, more extended, is fully exploited, guaranteeing excellent performance in terms of accuracy and speed, even during the calibration phase. A microprocessor monitors the different stages of the process and allows the correct repetition of the sequences of operation. Some accessories are available, like: PC interface, VSD (inverter), O2 control, O2+CO control, Profibus, Modbus. Fig. 1 GAS P100/M-LX-FGR-EL GAS XP60 - P100 - P150/M-LX-FGR-EL GAS BURNERS MODULATING LOW NOX WITH FGR SK073014_C_en CONTROL BOX LAMTEC BT3 Fig. 2 Control box Lamtec BT3 PRINCIPLE OF OPERATION BURNER WITH FGR In these burners, to recirculate the exhaust gases from the flue it is used the combustion air fan. N.B. THE ACTION OF THE FUEL AND AIR ACTUATORS IS NOT AFFECTED BY THE FLUE GAS RECIRCULATION. The FGR damper stays closed at the beginning of the pre-purge period. After the adjusted delay (parameter 414 of the BT3 - factory setting: 10) the pre-purge time is stopped temporarily and the recirculation actuator runs to OPEN position. When the FGR actuator reach the pre-purge position (set to the parameter 367), the pre-purge time resumes. At the end of the pre-purge time the air damper and the FGR damper runs to the ignition position; the fuel actuator is already in the ignition position. When the BT3 reach the ignition positions of the actuators, the burner ignites. When the BT3 change it operation in "MODULATION MODE", only the fuel and the air actuators run to the programmed curve. The FGR actuator remains at its position until the release conditions were met: - Condition 1: The time period set in parameter 331 of the BT3 - factory setting: 200, it must be expired and - Condition 2: The release temperature of the flue gas set in parameter 332 of the BT3 - factory setting: 50, it must be reached. When the 2 conditions are met, the FGR actuator runs to the programmed curve. You can see the spent time and the FGR temperature on the BT3 operating panel after the "MODULATION MODE". If, during the operation of the burner, the FGR temperature drops below the threshold set in parameter 332, the recirculation channel rmains active. During the burner operation, the recirculation channel runs to the close position in one of these conditions: - Condition 1: If the flue gas temperature drops below 0°C or - Condition 2: If the Pt100 temperature probe it fails or interrupts N.B. IF ONE OF THESE TWO CONDITIONS HAPPENS, THE BURNER KEEP OPERATING WITHOUT THE FGR RECIRCULATION CHANNEL. SO ONLY AIR AND FUEL ACTUATORS WORK THROUGH THE PROGRAMMED CURVE. When you turn off the burner, the recirculation channel will be closed together with the fuel actuator. GAS XP60 - P100 - P150/M-LX-FGR-EL GAS BURNERS MODULATING LOW NOX WITH FGR SK073014_C_en FGR (FLUE GAS RECIRCULATION) FGR (flue gas recirculation) it is a technique for lowering NOx emissions from burners. FGR lowers NOx in two ways: 1) The cooled, relatively inert, recirculated flue gases act as a heat sink, absorbing heat from the flame and lowering peak flame temperatures. 2) When mixed with the combustion air, recirculated flue gases lower the average oxygen content of the air, starving the NOx-forming reaction for one of the ingredients they need. The percentage of the flue gas back to the combustion chamber it is defined by the opening of the FGR actuator damper. FGR quantity must be adjusted so as to recirculate the smallest quantity necessary to obtain the required Nox rate. DISADVANTAGES OF THE FGR SYSTEM LOSS OF THE BURNER CAPACITY If you replace the combustion air with low oxygen flue gases, the burner has to be downrated to compensate for the reduced weight of oxygen flowing through it. You'll also suffer an additional capacity loss because the flue gas/combustion air mixture is at elevated temperature. LOSS OF THE BURNER STABILITY AND FLEXIBILITY The FGR system can be increase the emissions of he carbon monoxide and unburned hydrocarbons. GAS XP60 - P100 - P150/M-LX-FGR-EL GAS BURNERS MODULATING LOW NOX WITH FGR SK073014_C_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS XP60/M-LX-FGR-EL MODEL GAS XP60/M-LX-FGR-EL Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 130/200-474 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 151/232-551 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 15.4/23.7-56 Fuel: NATURAL GAS (second family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R)B NOx ** [mg/kWh] <30 Intermittent operation (min.1 stop every 24h), modulating Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Minimum pressure gas train D1"-S NATURAL GAS *** [mbar] 75 Maximum pressure at the entry of valves (Pe. max) [mbar] 360 Nominal electric power [W] 935 Fan motor [W] 740 Nominal fan motor current absorption [A] 2 Nominal auxiliary absorption [A] 0.5 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP 40 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** To obtain this low Nox emission like in the declaration, it's necessary to couple the burner to the proper boiler for this application: boilers with 3 turns for the exhaust gas, condensing boilers and any generator with direct exhaust outlet and the thermal load isn't higher then 1,8 MW/m³. *** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). >PEDU@ Fig. 3 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS XP60 - P100 - P150/M-LX-FGR-EL GAS BURNERS MODULATING LOW NOX WITH FGR SK073014_C_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS P100/M-LX-FGR-EL MODEL GAS P100/M-LX-FGR-EL Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 133/400-774 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 155/465-900 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 15.5/46.7-90.5 Fuel: NATURAL GAS (second family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R)B NOx ** [mg/kWh] <30 Continuous operation, modulating Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Minimum pressure gas train D1"1/2-S NATURAL GAS *** [mbar] 34 Maximum pressure at the entry of valves (Pe. max) [mbar] 360 Nominal electric power [kW] 2.7 Fan motor [kW] 2.2 Nominal fan motor current absorption [A] 5.4 Nominal auxiliary absorption [A] 0.5 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP 40 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** To obtain this low Nox emission…

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

FBR menghadirkan pembakar gas industri low NOx dengan FGR (Flue Gas Recirculation) seri XP60 - P100 - P150/M-LX-FGR-EL yang dirancang untuk aplikasi ketel uap dan pemanas industri. Pembakar ini mendukung pengoperasian dua tahap progresif (hi-low flame) atau modulasi penuh (PID) dengan rentang daya termal 280–1450 kW, konsumsi gas 20,1/58,3–116,7 Nm³/h, dan suplai listrik 3~400V, 1/N~230V-50Hz. Dilengkapi kontrol elektronik LAMTEC BT3, bodi aluminium die-cast, serta katup kerja dan pengaman yang terintegrasi dalam rangkaian gas terpasang.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi teknis FBR gas burner low NOx seri XP60 - P100 - P150/M-LX-FGR-EL?

Pembakar ini memiliki daya termal 280–1450 kW, nozzle 250 mm, berat 52 kg, motor kipas 1,5 kW, arus 3,6 A, proteksi IP 54, dan tingkat kebisingan 81–82 dBA. Suplai listrik 3~400V atau 1/N~230V-50Hz. Konsumsi gas berkisar 20,1 hingga 116,7 Nm³/h. Dilengkapi kontrol LAMTEC BT3 untuk modulasi PID.

Untuk apa FBR gas burner low NOx dengan FGR digunakan?

Pembakar ini digunakan pada ketel uap industri, pemanas thermal oil, dan tungku proses yang memerlukan emisi rendah NOx (< 60 mg/kWh, kelas 4). Sistem FGR (Flue Gas Recirculation) membantu menekan emisi. Cocok untuk aplikasi modulasi penuh atau dua tahap progresif di pabrik kelapa sawit, semen, dan industri F&B.

Bagaimana cara memilih FBR gas burner yang sesuai dengan kebutuhan saya?

Pilih berdasarkan daya termal yang dibutuhkan (280–1450 kW), jenis bahan bakar gas, dan tingkat emisi yang diinginkan. Pastikan suplai listrik sesuai (3~400V atau 1/N~230V-50Hz). Untuk modulasi penuh, tambahkan kit modulasi opsional dan probe. FBR menyediakan aktuator independen untuk gas, udara, dan FGR yang dikelola oleh electronic cam.

Di mana beli FBR gas burner low NOx di Indonesia?

Anda dapat membeli FBR gas burner low NOx seri XP60 - P100 - P150/M-LX-FGR-EL melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan kepabeanan untuk memastikan produk sampai ke lokasi proyek Anda.

Apa keunggulan FBR gas burner dengan kontrol LAMTEC BT3?

Kontrol LAMTEC BT3 memungkinkan penyesuaian parameter operasi, setpoint probe tekanan/suhu, dan kurva pembakaran melalui display. Dengan electronic cam, rasio gas/udara dijaga presisi untuk efisiensi maksimum. Opsi aksesori seperti PC interface, VSD (inverter), dan kontrol O2 atau O2+CO tersedia untuk optimasi lanjutan.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS P100/M CE-LX4 TL EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS P100/M CE-LX4 TL EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS P 100/2 CE-LX4 TC EVO Cl. 4 | Variant: variant_1 | Subgroup: Burner
FBR
GAS P 100/2 CE-LX4 TC EVO Cl. 4 | Variant: variant_1 | Subgroup: Burner
GAS P 100/2 CE-LX4 TL EVO Cl. 4 | Variant: variant_1 | Subgroup: Burner
FBR
GAS P 100/2 CE-LX4 TL EVO Cl. 4 | Variant: variant_1 | Subgroup: Burner
GAS P100/M CE-LX4 TC EVO Cl. 4 | Variant: metano | Subgroup: Burner
FBR
GAS P100/M CE-LX4 TC EVO Cl. 4 | Variant: metano | Subgroup: Burner
GAS P 130/M CE-LX4 TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS P 130/M CE-LX4 TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
FBR
GAS P 130/2 CE-LX4 TC EVO Cl. 4 | Variant: variant_1 | Subgroup: Burner

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL