Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

Pembakar industri gas satu tahap FBR seri GAS X0CE hingga X5CE dirancang untuk aplikasi pemanasan dengan emisi rendah, sesuai standar CE 676 kelas 3 (NOx < 80 mg/kWh). Model ini memiliki daya termal dari 11,6 kW…

SKU 3G-FBR-00477

Juga terdaftar sebagai: 00260531 · 002605 31 · 002605-31

Merek
FBR
Item
variant_2
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
stage
Single stage
fuel type
Gas low nox
nozzle mm
160
power kw max
245
power kw min
26
power kcal max
542
power kcal min
200
gas consumption
6.8/18.1-40.2
electrical supply
1
thermal power mcal h
58.5/154.8-344

Konten Lembar Data

GAS BURNERS ONE STAGE SK_071054_E_en GAS X0-X1-X2-X3-X4-X5CE Gas burners one stage with: die-cast aluminum body, fan at high pressurisation, combustion head with adjustment at high efficiency and high flame stability and protection cover with noise reduction plate. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or G.P.L. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled, electrically linked and tested; complete of working valve with flow adjustment, safety valve, minimum gas pressure switch and stabiliser filter of gas pressure. Versions F with cover of protection in steel and specific features for the application on industrial ovens and bakery ovens. Complete of connector plug / socket 7 poles, flange and gasket for installation on generator. Fig. 1 GAS X0CE Fig. 2 GAS X2CE Fig. 3 GAS X3CE Fig. 4 GAS X4CE Fig. 5 GAS X5CE GAS X0-X1-X2-X3-X4-X5CE GAS BURNERS ONE STAGE SK_071054_E_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM MODEL GAS X0CE GAS X1CE GAS X2CE GAS X3CE GAS X4CE GAS X5CE Thermal power min. - max. * [Mcal/h] 10-29.5 20-50 35-80 60-150 100-200 130-300 Thermal power min. - max. * [kW] 11.6-34.3 23.2-58.1 40.7-93 69.8-174 116-232 151-349 Gas flow G20 (NATURAL GAS) min. - max. * [Nm³/h] 1.2-3.4 2.3-5.8 4.1-9.4 7-17.5 11.7-23.4 15.2-35.1 Gas flow G31 (L.P.G.) min. - max. * [Nm³/h] 0.5-1.3 0.9-2.2 1.6-3.6 2.7-6.8 4.5-9 5.8-13.5 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) / I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) one stage Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 60 60 60 60 Min. pressure gas train D1/2"-S NATURAL GAS/L.P.G. ** [mbar] 7/18 14/31 - - - - Min. pressure gas train D3/4"-S NATURAL GAS/L.P.G. ** [mbar] - - 18/24 - - - Min. pressure gas train D1"-S NATURAL GAS/L.P.G. ** [mbar] - - - 14/31 14/21 27/33 Min. pressure gas train D1"1/4-S NATURAL GAS/L.P.G. [mbar] - - - - - 16/25 ** Max. pressure at the entry of valves (Pe. max) [mbar] 60 60 360 360 360 360 Nominal electric power [W] 80 110 130 200 226 540 Fan motor [W] 50 75 75 110 200 370 Nominal motor current absorption [A] 0.5 0.6 0.6 0.9 1.1 2.4 Power supply: 1/N~230V-50Hz Electric protection degree: IP 40 IP 40 IP 40 IP 40 IP 40 IP 40 Noisiness *** min. - max. [dB(A)] 52-55 59-60 60-61 64-66 64-66 67-71 Burner weight **** [kg] 8 10 10 13 15 24 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). **** For burners: GAS X0CE - GAS X1CE - GAS X2CE - GAS X3CE - GAS X4CE with cover in steel (F) add 3 kg to the weight. **** For burner GAS X5CE with cover in steel (F) add 5 kg to the weight. [mbar] [kW] [Mcal/h] Fig. 6 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS X0-X1-X2-X3-X4-X5CE GAS BURNERS ONE STAGE SK_071054_E_en DIMENSIONS [mm] Fig. 7 Dimensions GAS X0CE - GAS X1CE - GAS X2CE - GAS X3CE - GAS X4CE MODEL A B C D E F G H P S TC TL * R1 R2 R3 R4 RD Gas train weight GAS X0CE D1/2"-S 15 140 140 90 43 265 169 72 150 150 90 150 132 200 254 240 Rp 1/2 2 kg GAS X1CE D1/2"-S 15 162 175 90 43 305 210 65 150 150 90 150 132 200 254 240 Rp 1/2 2 kg GAS X2CE D3/4"-S 15 162 175 90 43 305 210 65 150 150 90 150 138 220 262 328 Rp 3/4 3 kg GAS X3CE D1"-S 16 185 195 108 54 340 248 70 200 160 130 250 168 280 337 361 Rp 1 8 kg GAS X4CE D1"-S 20 185 195 125 78 368 248 70 200 200 160 280 173 280 337 385 Rp 1 8 kg Fig. 8 Dimensions GAS X5CE MODEL A B C D E F G H P S TC TL * R1 R2 R3 R4 RD Gas train weight GAS X5CE D1"-S 18 207 213 138 98 462 310 90 200 200 250 335 160 305 362 403 Rp 1 8 kg GAS X5CE CT-D1"-S 18 207 213 138 98 462 310 90 200 200 250 335 160 305 480 403 Rp 1 9 kg GAS X5CE D1"1/4-S 18 207 213 138 98 462 310 90 200 200 250 335 160 305 362 450 Rp 1 1/4 8 kg GAS X5CE CT-D1"1/4-S 18 207 213 138 98 462 310 90 200 200 250 335 160 305 480 450 Rp 1 1/4 9 kg * For different flame lengths, please contact our Technical-Sales Department. BOILER PLATE ** Suggested dimension of connection between burner and generator. Fig. 9 Boiler plate MODEL L min L** L max M N min N** N max GAS X0CE mm 130 150 170 M8 100 110 130 GAS X1CE mm 130 150 170 M8 100 110 130 GAS X2CE mm 130 150 170 M8 100 110 130 GAS X3CE mm 150 170 170 M8 120 130 140 GAS X4CE mm 170 205 226 M10 130 140 160 GAS X5CE mm 205 226 226 M10 150 150 180 GAS X0-X1-X2-X3-X4-X5CE GAS BURNERS ONE STAGE SK_071054_E_en PRODUCT SPECIFICATION SHORT DESCRIPTION Gas burners on stage. DETAILED SPECIFICATION Gas burner one stage composed by: • Die-cast aluminum body; • Fan at high pressurisation; • Combustion head with adjustment at high performance and elevated flame stability equipped with inox steel blast tube and steel flame disc; • Protection cover with noise reduction plate; • Flange and insulating gasket for fixing at boiler; • Single-phase power supply; • Safety air pressure switch to stop the burner in case of failed or anomalous fan operation; • Gas train with safety valve and adjustment valve; • Ionisation probe for flame detection; • IP 40 electric protection level. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive M.D.; • GAS 2016/426/UE Regulation; • Reference rules: EN676 (gas) – EN 746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Isomart gasket; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Antivibration couplings; • Handle gas taps. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of…

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pembakar industri gas satu tahap FBR seri GAS X0CE hingga X5CE dirancang untuk aplikasi pemanasan dengan emisi rendah, sesuai standar CE 676 kelas 3 (NOx < 80 mg/kWh). Model ini memiliki daya termal dari 11,6 kW hingga 349 kW, dengan konsumsi gas G20 mulai 1,2 Nm³/h hingga 35,1 Nm³/h. Dilengkapi bodi aluminium die-cast, kepala pembakaran efisiensi tinggi, dan rangkaian gas terintegrasi yang telah diuji, menjadikannya pilihan andal untuk ketel uap dan oven industri. Cari pembakar gas satu tahap untuk kebutuhan industri Anda?

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi teknis pembakar gas FBR seri GAS X0CE?

Pembakar gas FBR seri GAS X0CE memiliki daya termal 11,6–34,3 kW, konsumsi gas G20 1,2–3,4 Nm³/h, dan gas G31 0,5–1,3 Nm³/h. Beroperasi satu tahap dengan tekanan gas minimal D1/2"-S untuk gas alam. Cocok untuk aplikasi industri dengan emisi rendah.

Untuk apa pembakar gas FBR seri GAS X0CE digunakan?

Pembakar gas FBR seri GAS X0CE digunakan pada ketel uap, oven industri, dan oven roti. Dirancang untuk pembakaran gas alam atau LPG satu tahap dengan efisiensi tinggi dan emisi NOx rendah (< 80 mg/kWh), sesuai standar CE 676 kelas 3.

Apa perbedaan antara model GAS X0CE hingga GAS X5CE?

Perbedaan utama terletak pada rentang daya termal: GAS X0CE (11,6–34,3 kW), GAS X1CE (23,2–58,1 kW), GAS X2CE (40,7–93 kW), GAS X3CE (69,8–174 kW), GAS X4CE (116–232 kW), dan GAS X5CE (151–349 kW). Semua model satu tahap dengan fitur serupa.

Di mana beli pembakar gas FBR di Indonesia?

Anda dapat membeli pembakar gas FBR seri GAS X0CE hingga X5CE melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Bagaimana cara memilih model pembakar gas FBR yang tepat?

Pilih model berdasarkan kebutuhan daya termal: untuk aplikasi kecil, GAS X0CE (11,6–34,3 kW); untuk lebih besar, GAS X5CE (151–349 kW). Pastikan tekanan gas sesuai (min. D1/2"-S untuk gas alam) dan jenis bahan bakar (gas alam atau LPG). Konsultasikan dengan teknisi untuk penyesuaian.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS X4/M CE-LX4 TL Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X4/M CE-LX4 TL Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS X4/2 CE-LX4 TL Cl. | Variant: variant_2 | Subgroup: Burner
FBR
GAS X4/2 CE-LX4 TL Cl. | Variant: variant_2 | Subgroup: Burner
GAS X4 CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X4 CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS X4/2 CE-LX4 TO Cl. | Variant: variant_2 | Subgroup: Burner
FBR
GAS X4/2 CE-LX4 TO Cl. | Variant: variant_2 | Subgroup: Burner
GAS X5 CE-LX4 TL Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X5 CE-LX4 TL Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS X4/M CE-LX4 TC CL.4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X4/M CE-LX4 TC CL.4 | Variant: variant_2 | Subgroup: Burner

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL