Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

Pembakar gas dua tahap FBR GAS X4/2CE dirancang untuk aplikasi industri dengan emisi rendah, tersertifikasi CE 676 kelas 4 (NOx ≤ 60 mg/kWh). Model ini memiliki daya termal 23–400 kW, konsumsi gas 6,8/18,1–40,2…

SKU 3G-FBR-00381

Juga terdaftar sebagai: 00229641 · 002296 41 · 002296-41

Merek
FBR
Item
variant_2
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
11 kg
stage
2 stages
fuel type
Gas low nox
nozzle mm
250
fan motor w
75
power kw max
400
power kw min
23
ip protection
IP 40
noisiness dba
61-62
gas consumption
6.8/18.1-40.2
electrical supply
1
power supply info
1/N~230V-50Hz
current absorption a
0.6
thermal power mcal h
58.5/154.8-344
nominal electric power w
130
max combustion air temp c
60

Konten Lembar Data

GAS BURNERS TWO STAGES SK071055_B_en GAS BURNERS TWO STAGES GAS X1/2CE - GAS X2/2CE - GAS X3/2CE - GAS X4/2CE - GAS X5/2CE Gas burners two stages with: aluminum body, fan at high pressurisation and combustion head with adjustment at high efficiency and high flame stability and protection cover with noise reduction plate. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled, electrically linked and tested; complete of two stages working valve with flow adjustment, safety valve, minimum gas pressure switch and stabiliser filter of gas pressure. Versions F with cover of protection in steel and specific features for the application on industrial ovens and bakery ovens. Complete of connector plug / socket 7 poles, flange and gasket for installation on generator. Fig. 1 GAS X4/2CE GAS X1/2CE - GAS X2/2CE - GAS X3/2CE - GAS X4/2CE - GAS X5/2CE GAS BURNERS TWO STAGES SK071055_B_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS X1/2CE - GAS X2/2CE MODEL GAS X1/2CE GAS X2/2CE Thermal power min. - max. * [Mcal/h] 15.5/20-50 21/35-80 Thermal power min. - max. * [kW] 18/23.2-58.1 24.4/40.7-93 Gas flow G20 (NATURAL GAS) min. - max. * [Nm³/h] 1.8/2.3-5.8 2.5/4.1-9.4 Gas flow G31 (L.P.G.) min. - max. * [Nm³/h] 0.7/0.9-2.3 0.9/1.6-3.6 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) / I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 Min. pressure gas train D1/2"-S NATURAL GAS/L.P.G. ** [mbar] 14/31 - Min. pressure gas train D3/4"-S NATURAL GAS/L.P.G. ** [mbar] - 14/28 Max. pressure at the entry of valves (Pe. max) [mbar] 60 360 Nominal electric power [W] 110 130 Fan motor [W] 75 75 Nominal motor current absorption [A] 0.55 0.55 Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 IP 40 Noisiness *** min. - max. [dB(A)] 60-61 61-62 Burner weight **** [kg] 11 11.5 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - method of control Class 3 - The tollerance of the measured pressure can be taken equal to ± 1 [dB(A)]). **** For burner with cover in steel (F) add 3 kg to the weight. [mbar] 3 GAS X1/2 GAS X2/2 2 1 0 -1 0 50 100 [kW] 0 50 100 [Mcal/h] Fig. 2 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS X1/2CE - GAS X2/2CE - GAS X3/2CE - GAS X4/2CE - GAS X5/2CE GAS BURNERS TWO STAGES SK071055_B_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS X3/2CE - GAS X4/2CE MODEL GAS X3/2CE GAS X4/2CE Thermal power min. - max. * [Mcal/h] 30/60-150 55/100-200 Thermal power min. - max. * [kW] 34.9/69.8-174 64/116-232 Gas flow G20 (NATURAL GAS) min. - max. * [Nm³/h] 3.5/7-17.4 6.4/11.6-23.2 Gas flow G31 (L.P.G.) min. - max. * [Nm³/h] 1.3/2.7-6.5 2.5/4.5-9 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) / I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 Min. pressure gas train D1"-S NATURAL GAS/L.P.G. ** [mbar] 14/31 14/21 Min. pressure gas train D1"1/4-S NATURAL GAS/L.P.G. ** [mbar] 11/30 11/19 Min. pressure gas train D1"1/2-S NATURAL GAS/L.P.G. ** [mbar] 10/28 8/17 Max. pressure at the entry of valves (Pe. max) [mbar] 360 360 Nominal electric power [W] 200 226 Fan motor [W] 110 200 Nominal motor current absorption [A] 0.77 1.35 Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 IP 40 Noisiness *** min. - max. [dB(A)] 66-69 66-69 Burner weight **** [kg] 16 19 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - method of control Class 3 - The tollerance of the measured pressure can be taken equal to ± 1 [dB(A)]). **** For burner with cover in steel (F) add 3 kg to the weight. [PEDU] 6 5 4 3 2 GAS X3/2 GAS X4/2 1 0 -1 0 50 100 150 200 250 [ kW ] 0 50 100 150 200 [Mcal/h] Fig. 3 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS X1/2CE - GAS X2/2CE - GAS X3/2CE - GAS X4/2CE - GAS X5/2CE GAS BURNERS TWO STAGES SK071055_B_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS X5/2CE MODEL GAS X5/2CE Thermal power min. - max. * [Mcal/h] 70/130-300 Thermal power min. - max. * [kW] 81.4/151-349 Gas flow G20 (NATURAL GAS) min. - max. * [Nm³/h] 8.2/15.2-35 Gas flow G31 (L.P.G.) min. - max. * [Nm³/h] 3.2/5.8-13.5 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) / I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Min. pressure gas train D1"-S NATURAL GAS/L.P.G. ** [mbar] 27/33 Min. pressure gas train D1"1/4-S NATURAL GAS/L.P.G. ** [mbar] 16/25 Min. pressure gas train D1"1/2-S NATURAL GAS/L.P.G. ** [mbar] 15/12 Max. pressure at the entry of valves (Pe. max) [mbar] 360 Nominal electric power [W]…

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pembakar gas dua tahap FBR GAS X4/2CE dirancang untuk aplikasi industri dengan emisi rendah, tersertifikasi CE 676 kelas 4 (NOx ≤ 60 mg/kWh). Model ini memiliki daya termal 23–400 kW, konsumsi gas 6,8/18,1–40,2 Nm³/h, dan dilengkapi motor kipas 75 W dengan catu daya 1/N~230V-50Hz. Produk ini cocok untuk berbagai kebutuhan pembakar industri berkinerja tinggi di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi teknis FBR GAS X4/2CE?

FBR GAS X4/2CE adalah pembakar gas dua tahap dengan daya termal minimal 23 kW dan maksimal 400 kW. Konsumsi gas berkisar 6,8/18,1–40,2 Nm³/h, motor kipas 75 W, dan catu daya 1/N~230V-50Hz dengan arus 0,6 A. Perlindungan IP 40 dan tingkat kebisingan 61–62 dBA.

Untuk apa FBR GAS X4/2CE digunakan?

Pembakar gas FBR GAS X4/2CE digunakan pada ketel uap industri, oven industri, dan aplikasi pembakaran lainnya yang memerlukan emisi rendah. Produk ini cocok untuk gas alam (metana) atau LPG, dengan dua tahap pembakaran untuk efisiensi tinggi dan stabilitas nyala api.

Apakah FBR GAS X4/2CE memiliki sertifikasi?

Ya, FBR GAS X4/2CE tersertifikasi CE 676 kelas 4 dengan emisi NOx ≤ 60 mg/kWh, menjadikannya pembakar gas rendah emisi. Sertifikasi ini memastikan kepatuhan terhadap standar lingkungan Eropa untuk aplikasi industri.

Bagaimana cara memilih FBR GAS X4/2CE yang tepat?

Pilih FBR GAS X4/2CE berdasarkan daya termal yang dibutuhkan (23–400 kW) dan jenis gas (metana atau LPG). Pastikan tekanan gas minimal 14 mbar untuk gas alam atau 31 mbar untuk LPG pada saluran gas D1/2". Periksa juga suhu udara pembakaran maksimal 60°C.

Di mana beli FBR GAS X4/2CE di Indonesia?

Anda dapat membeli FBR GAS X4/2CE melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda dengan aman.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS X5 CE-LX4 TL Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X5 CE-LX4 TL Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS X5/2 CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X5/2 CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS X5/M CE-LX4 TL EL CL.4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X5/M CE-LX4 TL EL CL.4 | Variant: variant_2 | Subgroup: Burner
GAS X5 CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X5 CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
X GAS X5/2 CE TL | Variant: variant_2 | Subgroup: Burner
FBR
X GAS X5/2 CE TL | Variant: variant_2 | Subgroup: Burner
FBR
FBR
GAS X5/2 CE-LX4 TL Cl. | Variant: metano | Subgroup: Burner

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL