Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FBR varian_2 - Burners & Combustion
FBRBurners & Combustion

FBR varian_2

Pembakar industri gas FBR GAS X5/MCE-EL adalah solusi pembakaran dua tahap progresif atau modulasi (PID fully modulating) dengan daya termal maksimal 400 kW dan daya minimal 68 kW. Dirancang untuk emisi rendah (NOx ≤…

SKU 3G-FBR-00375

Juga terdaftar sebagai: 00219841 · 002198 41 · 002198-41

Merek
FBR
Item
varian_2
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
15 kg
stage
2 stages sliding or modulating
fuel type
Gas low nox
nozzle mm
250
fan motor w
200
power kw max
400
power kw min
68
ip protection
IP
noisiness dba
66-68
gas consumption
6.8/18.1-40.2
electrical supply
1
power supply info
1/N~230V-50Hz
current absorption a
1.1
thermal power mcal h
58.5/154.8-344
nominal electric power w
260
max combustion air temp c
60

Konten Lembar Data

GAS BURNERS TWO STAGES PROGRESSIVE OR SK073037_E_gb MODULATING GAS X5/MCE-EL Burners for gas modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe. Composed by: die-cast aluminum body, fan at high pressurisation, combustion head with adjustment at high efficiency and high flame stability and protection cover with noise reduction plate. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for operations of setting and maintenance. Available in the versions METHANE (natural gas) or G.P.L. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train complete of: one-block valve class A (1st stage slow opening + safety), minimum gas pressure switch, filter, stabiliser of gas pressure. Complete of flange and gasket for installation on generator. Electronic control box Lamtec BT3 with microprocessor and two servomotors for air and gas adjustment. Interactive set-up LCD display. The fuel / combustion air curve, with electronic cam device, is fully exploited, guaranteeing excellent performance in terms of accuracy and speed, even during the calibration phase. A microprocessor monitors the different stages of the process and allows the correct repetition of the sequences of operation. GAS X5/MCE-EL GAS BURNERS TWO STAGES PROGRESSIVE OR SK073037_E_gb MODULATING TECHNICAL DATA AND WORKING RANGE DIAGRAM GAS X5/MCE-EL MODEL GAS X5/MCE-EL Thermal power min. 1°st. / min. 2°st. - max. 2° st.* [Mcal/h] 60/130-300 Thermal power min. 1°st. / min. 2°st. - max. 2° st.* [kW] 69.8/151-349 Gas flow G20 (NATURAL GAS) min 1°st./2°st.-max 2° st.* [Nm³/h] 7/15.2-35 Gas flow G31 (L.P.G.) min 1°st./2°st.-max 2° st.* [Nm³/h] 2.7/5.8-13.5 Fuel: Natural gas (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) I3B/P,I3+,I3P,I3B,I3R Intermittent working operation (min. 1 STOP every 24 hours), two stages progressive or modulating Environmental conditions operation/storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max temperature combustion air [°C] 60 Minimum pressure gas train D1"-S NATURAL GAS/LPG ** [mbar] 27/33 Minimum pressure gas train D1"1/4-S NATURAL GAS/LPG ** [mbar] 16/25 Minimum pressure gas train D1"1/2-S NATURAL GAS/LPG ** [mbar] 13/- Maximum pressure at the entry of the valves (Pe.max) [mbar] 360 Nominal electric power [W] 540 Fan motor [W] 370 Nominal absorption [A] 2.4 Power supply: 1/N~230V-50Hz Degree of electric protection: IP 40 Noisiness *** min-max [dB(A)] 66-71 Weight burner **** [kg] 35 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level) ** Pressure of feeding of the gas to the ramp to get the maximum power of the burner considering against pressure in chamber of value combustion 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law -method of control Class 3 - The tollerance of the measured pressure can be taken equal to ± 1 [dB(A)]). **** For burner with cover in steel (F) to add 4 kg to the weight. [mbar] [kW] [Mcal/h] Fig. 1 X = Thermal power Y = Pressure in combustion chamber The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner bruciatore, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS X5/MCE-EL GAS BURNERS TWO STAGES PROGRESSIVE SK073037_E_gb OR MODULATING DIMENSIONS [MM] Fig. 2 Dimensions MODEL A B C D E F G O R1 R2 R3 R4 RD Weight gas train GAS X5/MCE-EL D1"-S 207 213 98 138 462 310 165 200 160 305 362 515 Rp 1" 6 kg GAS X5/MCE-EL D1"1/4-S 207 213 98 138 462 310 165 200 160 305 362 515 Rp 1"1/4 6 kg GAS X5/MCE-EL D1"1/2-S 207 213 98 138 462 310 165 200 170 305 353 605 Rp 1"1/2 8 kg * SEE "MOUNTING POSITIONS FOR GAS TRAIN" ** SEE "FLAME TUBE LENGTH" BOILER PLATE The dimensions of the boiler plate must be as indicated in the drawing. Fig. 3 Boiler plate MODEL L min L max M N min N max GAS X5/MCE-EL mm 205 226 M10 150 180 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC * TL * GAS X5/MCE-EL mm 250 335 * For different flame lengths, please contact our Technical-Sales Department. GAS X5/MCE-EL GAS BURNERS TWO STAGES PROGRESSIVE SK073037_E_gb OR MODULATING PRODUCT SPECIFICATION SHORT DESCRIPTION Gas burners modulating (PID fully modulating) if equipped with modulation kit and probe. DETAILED SPECIFICATION Gas burner modulating (PID fully modulating) with optional modulation kit and probe, composed by: • Die-cast aluminum body; • Fan at high pressurisation; • Combustion head with adjustment at high performance and elevated flame stability equipped with inox steel blast tube and steel flame disc; • Combustible-air adjustment for optimal combustion value; • Protection cover with noise reduction plate; • Flange and insulating gasket for fixing at generator; • Electronic control system for controlling and command the burner; • Single-phase power supply; • Safety air pressure switch to stop the burner in case of failed or anomalous fan operation; • Spherical gas servocontrolled valve: progressive start and free way passage with total opening; • Servomotor for air shutter; • Servomotor for spherical gas valve; • Mobile shutter with total closure when idle for minimize the energetic losses related at boiler cooling; • Gas train complete of: one-block valve class A (1st stage slow opening + safety), minimum gas pressure switch, filter, stabiliser of gas pressure; • Ionisation probe for flame detection; • IP 40 electric protection level; • Set up for the additional specific kit that transforms burner operation as modulating i.e.the modulating kit allows to supply any power between the minimum and maximum value based on instantaneous loading request. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive M.D.; • GAS 2016/426/UE Regulation; • Reference rules: EN676 (gas) – EN 746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Isomart gasket; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Power modulating kits for temperatures; • Power modulating kits for pressures; • Temperature probe 0°C - 400°C (PT 100 ohm at 0° C); • Temperature probe 0°C - 1200°C (K probe); • Pressure probe 0-3 bar, 0-6 bar, 0-16 bar, 0-20 bar, 0-30 bar; • Antivibration couplings; • Handle gas taps. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. GAS X5/MCE-EL

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pembakar industri gas FBR GAS X5/MCE-EL adalah solusi pembakaran dua tahap progresif atau modulasi (PID fully modulating) dengan daya termal maksimal 400 kW dan daya minimal 68 kW. Dirancang untuk emisi rendah (NOx ≤ 60 mg/kWh) dan tersertifikasi CE kelas 4, produk ini cocok untuk aplikasi gas alam (metana) atau LPG. Dilengkapi katup gas satu blok kelas A, filter, stabilisator tekanan, serta kotak kontrol elektronik Lamtec BT3 dengan layar LCD interaktif. Cari suku cadang pembakar FBR? Produk ini tersedia di Indonesia melalui distributor resmi.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi teknis FBR GAS X5/MCE-EL?

Pembakar industri FBR GAS X5/MCE-EL memiliki daya termal 68–400 kW, konsumsi gas G20 6,8–40,2 Nm³/jam, dan suplai listrik 1/N~230V-50Hz dengan arus 1,1 A. Dilengkapi motor kipas 200 W, perlindungan IP, dan tingkat kebisingan 66–68 dBA. Produk ini cocok untuk gas alam atau LPG dengan emisi NOx rendah.

Untuk apa FBR GAS X5/MCE-EL digunakan?

Pembakar gas FBR GAS X5/MCE-EL digunakan pada ketel uap industri, pemanas udara, atau proses termal lain yang membutuhkan pembakaran dua tahap progresif atau modulasi. Dengan daya 68–400 kW dan emisi rendah, produk ini ideal untuk aplikasi industri seperti pabrik kelapa sawit, semen, atau pengolahan makanan.

Bagaimana cara memilih FBR GAS X5/MCE-EL yang tepat?

Pilih FBR GAS X5/MCE-EL berdasarkan daya termal yang dibutuhkan (68–400 kW) dan jenis bahan bakar (gas alam atau LPG). Pastikan suplai listrik 230V-50Hz tersedia. Untuk aplikasi modulasi penuh, tambahkan kit modulasi opsional dan probe. Konsultasikan dengan teknisi untuk penyesuaian kepala pembakaran dan rangkaian gas.

Di mana beli FBR GAS X5/MCE-EL di Indonesia?

Anda dapat membeli FBR GAS X5/MCE-EL melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda. Hubungi kami untuk minta penawaran.

Apa keunggulan FBR GAS X5/MCE-EL dibandingkan pembakar lain?

FBR GAS X5/MCE-EL menawarkan emisi NOx rendah (≤ 60 mg/kWh) dengan sertifikasi CE kelas 4, kontrol elektronik Lamtec BT3 untuk akurasi tinggi, dan desain kompak dengan akses mudah untuk perawatan. Dilengkapi katup gas satu blok kelas A, filter, dan stabilisator tekanan untuk keandalan operasi.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS X5 CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X5 CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS X5/2 CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X5/2 CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS X5/M CE-LX4 TL EL CL.4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X5/M CE-LX4 TL EL CL.4 | Variant: variant_2 | Subgroup: Burner
GAS X5 CE-LX4 TL Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X5 CE-LX4 TL Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS X2/M CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X2/M CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS X4/M CE-LX4 TC CL.4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X4/M CE-LX4 TC CL.4 | Variant: variant_2 | Subgroup: Burner

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL