Konten Lembar Data
GAS BURNERS TWO STAGES PROGRESSIVE OR
SK073015_2_B
MODULATING
GASBURNERSTWOSTAGESPROGRESSIVEORMODULATING
GASXP60/MCE-EVO
Burnersforgastwostagesprogressive(hi-lowflame)ormodulating(PIDfullymodulating)ifequippedwithaddition
ofoptionalmodulationkitandprobe.
Theyarecomposedby:fanathighpressurisationwithreversebladesandcombustionheadwithadjustmentathigh
efficiencyandhighflamestability.
Compactoveralldimensionsanddispositionrationalizedofthecomponentswithaccessibilityfacilitatedforthe
operationsofsettingandmaintenance.
AvailableintheversionsMETHANE(naturalgas)orL.P.G.(tospecifyattheorder)ondemandspecificversionsfor
towngas,coalgasorbiogas.
Gastraincompletelyassembledandtested;completeofworkingvalvewithflowadjustment,safetyvalve,minimum
gaspressureswitchandgasfilter.
Completeofflangeandgasketforinstallationongenerator.
Fig. 1 GASXP60/MCE-EVO
GAS XP60/MCE-EVO
GAS BURNERS TWO STAGES PROGRESSIVE OR
SK073015_2_B
MODULATING
TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS XP60/MCE-EVO
MODEL GAS XP60/MCE-EVO
Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 92/200-542
Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 107/232-630
Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 10.7/23.3-63.3
Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 4/9-24.5
Fuel: NATURAL GAS (second family) - L.P.G. (third family)
Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R)
I3B/P,I3+,I3P,I3B,I3R
Intermitted working operation (min. 1 stop every 24 hours) two stages
Environmental conditions operation / storage: -15...+40°C / -20...+70°C, umidità rel. max. 80%
Max. temperature combustion air [°C] 60
Minimum pressure gas train D1"-S NATURAL GAS/L.P.G. ** [mbar] 115.3 / 60
Minimum pressure gas train D1"1/4-S NATURAL GAS/L.P.G. ** [mbar] 54.5 / 37.4
Minimum pressure gas train D1"1/2-S NATURAL GAS/L.P.G. ** [mbar] 17.7 / 21.8
Maximum pressure at the entry of valves (Pe. max) [mbar] 360
Nominal electric power [W] 700
Fan motor [W] 550
Nominal motor current absorption [A] 1.4
Nominal auxiliary absorption [A] 0.5
Power supply: 3~400V, 1N~230V - 50Hz
Electric protection degree: IP 40
Noisiness *** min. - max. [dB(A)] 69-72
Burner weight **** [kg] 34.5
* Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level).
** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of
value 0 (zero).
*** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 -
Control method Class 3 - The tolerance on the measured sound pressure can be assumed equal to ± 1 [dB (A)]).
**** For burner with long head add 1 kg to the weight.
[mbar] 11
9
7
5
3
1
GAS XP60/M
-1
0 100 200 300 400 500 600 [kW]
Fig. 2 X = Thermal power Y = Pression in the combustion chamber
The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler.
For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance,
contact the manufacturer.
GAS XP60/MCE-EVO
GAS BURNERS TWO STAGES PROGRESSIVE OR
SK073015_2_B
MODULATING
DIMENSIONS [MM]
A
B S
A H
D
R1
G
RD TC-TL E
M
R4
R2 C
N
R3
Fig. 3 Dimensions GAS XP60/MCE-EVO
MODEL A B C D E G H M N S R1 R2 R3 R4 RD
GASXP60/MCE-EVO-D1"-S 200 330 275 150 99 417 100 298 558 20 240 414 472 444 Rp 1
GASXP60/MCE-EVO-D1"1/4-S 200 330 275 150 99 417 100 298 558 20 240 414 472 444 Rp 1 1/4
GASXP60/MCE-EVO-D1"1/2-S 200 330 275 150 99 417 100 298 558 20 240 414 480 460 Rp 1 1/2
BOILER PLATE
* Suggested dimension of connection between burner
and generator.
Fig. 4 Boiler plate
MODEL L min L* L max M N min N* N max
GASXP60/MCE-EVO mm 160 160 180 M10 205 205 226
FLAME TUBE LENGTH
Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it
must be greater than the thickness of the boiler door included its insulation.
In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between
the flame tube and front door with refractory material. This protection material must not impede flame tube extraction.
MODEL TC TL **
GASXP60/MCE-EVO mm 250 335
** For different flame lengths, please contact our Technical-Sales Department.
GAS XP60/MCE-EVO
GAS BURNERS TWO STAGES PROGRESSIVE OR
SK073015_2_B
MODULATING
BURNER SIGNAL DESCRIPTION
In the picture below there are indicated all the signalation present on the burner:
2 1
Fig. 5 Burner signal description
LEGEND
1) ON/OFF button
2) Reset from lockout button + status lamp
The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics
and interface diagnostics.
In normal operation, the different operating states are indicated in the form of color codes; please refer to
electrical device handbook supplied with the present instructions.
After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up.
By pressing the lockout reset button (pos.2) for more than 3 seconds, the visual diagnostics of the cause of fault
can be activated; please refer to electrical device handbook supplied with the present instructions.
For close the diagnostics mode and for switch on the burner again, it is necessary to reset the burner control.
Press the lockout reset button (pos.2) for about 1 second (<3 seconds).
After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up.
For reset the control box press the lockout reset button (pos.2) for about 1 second (<3 seconds).
GAS XP60/MCE-EVO
GAS BURNERS TWO STAGES PROGRESSIVE OR
SK073015_2_B
MODULATING
PRODUCT SPECIFICATION
SHORT DESCRIPTION
Burners for gas two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition
of optional modulation kit and probe.
DETAILED SPECIFICATION
Burner for gas two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of
optional modulation kit and probe; composed by:
• Fan at high pressurisation with reversed blades;
• Combustion head with adjustment at high performance and elevated flame stability equipped with inox steel blast tube and
steel flame disc;
• Flange and insulating gasket for fixing at boiler;
• Three-phase power supply;
• Safety air pressure switch to stop the burner in…