Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FBR GPL - Burners & Combustion
FBRBurners & Combustion

FBR GPL

Pembakar industri FBR GAS XP80/2 CE adalah gas burner dua tahap (two stages) dengan emisi rendah kelas 4 (NOx < 60 mg/kWh) yang dirancang untuk aplikasi ketel uap dan peralatan pembakaran industri. Dengan daya termal…

SKU 3G-FBR-00423

Juga terdaftar sebagai: 00242241 · 002422 41 · 002422-41

Merek
FBR
Item
GPL
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
43 kg
stage
2 stages
fuel type
Gas low nox
nozzle mm
250
fan motor w
1.5
power kw max
850
power kw min
170
ip protection
IP 40
noisiness dba
79-82
gas consumption
17/40.8-85.3
electrical supply
3
power supply info
3~400V, 1/N~230V-50Hz
current absorption a
3.1
thermal power mcal h
146/350-731
nominal electric power w
1.7
max combustion air temp c
60

Konten Lembar Data

GAS XP80/2 CE GAS BURNERS TWO STAGES 071098_A_gb GAS BURNERS TWO STAGES GAS XP80/2 CE Gas burners two stages with: aluminum body, fan at high pressurisation and combution head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. The burner is mounted on supports and tierods for burner extraction this permits retreat to disassemble and check the flame tube and the combustion head. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled and tested; complete of two stages working valve with flow adjustment, safety valve, minimum gas pressure switch and stabiliser filter of gas pressure. Complete off lange and gasket for installation on generator. Fig. 1 GAS XP80/2 CE GAS XP80/2 CE GAS XP80/2 CE GAS BURNERS TWO STAGES 071098_A_gb TECHNICAL DATA AND OPERATING RANGE DIAGRAM XP80/2 CE MODEL GAS XP80/2 CE Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 146/350-731 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 170/407-850 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 17/40.8-85.3 Gas flow G25 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 19.8/47.5-99.1 Gas flow G25.3 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 19.4/46.4-97 Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 6.6/15.8-33 Fuel: NATURAL GAS (second family, G20, G25, G25.3) - L.P.G. (third family, G31) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Minimum pressure gas train D1"1/4-S NATURAL GAS/L.P.G. ** [mbar] 94/53 Minimum pressure gas train D1"1/2-S NATURAL GAS/L.P.G. ** [mbar] 24/24 Minimum pressure gas train D2"-S NATURAL GAS/L.P.G. ** [mbar] 21/23 Maximum pressure at the entry of valves (Pe. max) [mbar] 360 Nominal electric power [kW] 1.7 Fan motor [kW] 1.5 Nominal motor current absorption [A] 3.1 Nominal auxiliary absorption [A] 0.7 Power supply: 3~400V, 1/N~230V-50Hz Electric protection degree: IP 40 NOx Class, NATURAL GAS (second family) 1 NOx Class, L.P.G. (third family) 2 Noisiness *** min. - max. [dB(A)] 79-82 Burner weight **** [kg] 43 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - Control method class 3 - The measured sound pressure tolerance can be assumed to be ± 1 [dB (A)]). **** For burner with long head add 2 kg to the weight. GAS XP80/2 CE GAS XP80/2 CE GAS BURNERS TWO STAGES 071098_A_gb [mbar] 14 GAS XP80/2 CE 12 10 8 6 4 2 0 0 100 200 300 400 500 600 700 800 900 [kW] The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. DIMENSIONS [MM] Fig. 3 Dimensions GAS TRAIN A B D1"1/4-S 437 382* D1"1/2-S 458 396 D2"-S 458 396 * Includes length of 66 mm due to adapter code 057020 ** Overall dimension with the burner out in position of maintenance. TC - TL: Please see chapter "Flame tube length" GASXP80/2CE GAS XP80/2 CE GAS BURNERS TWO STAGES 071098_A_gb BOILER PLATE The dimensions of the boiler plate must be as indicated in the drawing. * Suggested dimension of connection between burner and generator. MODEL L min L* L max M N min N max GAS XP80/2 CE mm 185 185 250 M12 310 365 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. FLAME TUBE LENGTH TC mm 250 TL mm 385 ** ** For different flame lengths, please contact our Technical-Sales Department. GAS XP80/2 CE GAS XP80/2 CE GAS BURNERS TWO STAGES 071098_A_gb BURNER SIGNAL DESCRIPTION In the picture below there are indicated all the signalation present on the burner: 1 2 LEGEND 1) ON/OFF button 2) Reset from lockout button + status lamp The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics and interface diagnostics. In normal operation, the different operating states are indicated in the form of color codes; please refer to electrical device handbook supplied with the present instructions. After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. By pressing the lockout reset button (pos.2) for more than 3 seconds, the visual diagnostics of the cause of fault can be activated; please refer to electrical device handbook supplied with the present instructions. For close the diagnostics mode and for switch on the burner again, it is necessary to reset the burner control. Press the lockout reset button (pos.2) for about 1 second (<3 seconds). After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. For reset the control box press the lockout reset button (pos.2) for about 1 second (<3 seconds). GAS XP80/2 CE GAS XP80/2 CE GAS BURNERS TWO STAGES 071098_A_gb PRODUCT SPECIFICATION SHORT DESCRIPTION Gas burners two stages. DETAILED SPECIFICATION Gas burner two stages composed by: • Aluminum body; • Fan at high pressurisation; • Combustion head with adjustment at high performance and elevated flame stability equipped with inox steel blast tube and inox steel flame disc; • Flange and insulating gasket for fixing at boiler; • Three-phase power supply; • Safety air pressure switch to stop the burner in lock-out in case of failed or anomalous fan operation; • Gas train with safety valve class A, adjustment two stages valve class A; • Optional valve proving system; • Ionisation probe for flame detection; • IP 40 electric protection level; • Servomotor for air shutter and for the consent of the 2nd stage gas valve; • Moving shutter with total closure when idle in order to reduce at the least energy losses related to boiler cooling down; • Supports and tierods for burner extraction. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive M.D.; • GAS 2016/426/UE Regulation; • Reference rules: EN676 (gas) – EN 746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Isomart gasket; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise protection; •…

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pembakar industri FBR GAS XP80/2 CE adalah gas burner dua tahap (two stages) dengan emisi rendah kelas 4 (NOx < 60 mg/kWh) yang dirancang untuk aplikasi ketel uap dan peralatan pembakaran industri. Dengan daya termal maksimum 850 kW dan minimum 170 kW, burner ini memiliki konsumsi gas G20 sebesar 17/40.8-85.3 Nm³/h serta dilengkapi motor kipas 1,5 kW dan perlindungan IP 40. Cocok untuk penggunaan gas alam (metana) atau LPG, produk ini merupakan pilihan tepat untuk kebutuhan pembakar industri di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi teknis FBR GAS XP80/2 CE?

FBR GAS XP80/2 CE memiliki daya termal 170/407-850 kW (min. 1°st./min. 2°st.-max. 2°st.), konsumsi gas G20 17/40.8-85.3 Nm³/h, motor kipas 1,5 kW, arus 3,1 A, dan perlindungan IP 40. Suplai listrik 3~400V atau 1/N~230V-50Hz. Berat 43 kg dengan nozzle 250 mm.

Untuk apa FBR GAS XP80/2 CE digunakan?

Pembakar industri dua tahap ini digunakan pada ketel uap, pemanas industri, dan sistem pembakaran lainnya yang memerlukan emisi rendah (NOx < 60 mg/kWh). Cocok untuk gas alam (G20, G25, G25.3) atau LPG (G31) dengan operasi intermiten (maks. 1 stop per 24 jam).

Bagaimana cara memilih FBR GAS XP80/2 CE yang tepat?

Pastikan daya termal yang dibutuhkan sesuai rentang 170-850 kW dan jenis gas yang digunakan (natural gas atau LPG). Periksa suplai listrik (3~400V atau 1/N~230V-50Hz) serta tekanan gas minimum pada train gas D1"1/4-S. Suhu udara pembakaran maksimal 60°C.

Di mana beli FBR GAS XP80/2 CE di Indonesia?

Anda dapat membeli FBR GAS XP80/2 CE melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Apa keunggulan FBR GAS XP80/2 CE dibanding burner lain?

Burner ini memiliki emisi rendah kelas 4 (NOx < 60 mg/kWh), bodi aluminium, kipas bertekanan tinggi, dan kepala pembakaran yang dapat disetel untuk efisiensi tinggi. Dilengkapi katup kerja dua tahap, katup pengaman, sakelar tekanan gas minimum, dan filter stabiliser tekanan gas.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS XP 80/2 CE-LX4 TL Cl. 4 | Variant: GPL | Subgroup: Burner
FBR
GAS XP 80/2 CE-LX4 TL Cl. 4 | Variant: GPL | Subgroup: Burner
GAS XP 80/2 CE-LX4 TC Cl. 4 | Variant: variant_1 | Subgroup: Burner
FBR
GAS XP 80/2 CE-LX4 TC Cl. 4 | Variant: variant_1 | Subgroup: Burner
GAS XP 80/M CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 80/M CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS XP 80/2 CE-LX4 TL Cl. 4 | Variant: variant_1 | Subgroup: Burner
FBR
GAS XP 80/2 CE-LX4 TL Cl. 4 | Variant: variant_1 | Subgroup: Burner
GAS XP 80/M CE-LX4 TL Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 80/M CE-LX4 TL Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS XP 80/M CE-LX4 TC Cl. 4 | Variant: metano | Subgroup: Burner
FBR
GAS XP 80/M CE-LX4 TC Cl. 4 | Variant: metano | Subgroup: Burner

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL