Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

GASCO 103L-322-18BS Disposable Calibration Gas Cylinder - Calibration Gases for Portable Gas Detectors
GASCOCalibration Gases for Portable Gas Detectors

GASCO 103L-322-18BS Disposable Calibration Gas Cylinder

GASCO Calibration Gas: Nitrogen adalah gas kalibrasi sekali pakai (disposable) dengan campuran Carbon Monoxide 100 ppm dan akurasi +/-5%, dirancang untuk digunakan dengan semua detektor gas OEM. Produk ini…

SKU 3G-OTH-550512

Juga terdaftar sebagai: 103L32218BS · 103L 322 18BS

Merek
GASCO
Item
103L-322-18BS Disposable Calibration Gas Cylinder
Kategori
Calibration Gases for Portable Gas Detectors
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

GASCO
Manufacturer Part Number
103L-322-18BS
Type
Disposable, +/-5% Accuracy, C5H12/CO/O2, Calibration Gas, Cylinder
Gas Mixture
Carbon Monoxide 100 ppm
Reusability
Disposable
For Use With
All OEM Gas Detectors
Background Gas
Nitrogen

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

GASCO Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

GASCO Calibration Gas: Nitrogen adalah gas kalibrasi sekali pakai (disposable) dengan campuran Carbon Monoxide 100 ppm dan akurasi +/-5%, dirancang untuk digunakan dengan semua detektor gas OEM. Produk ini menggunakan Nitrogen sebagai gas latar belakang dan tersedia dalam kemasan silinder dengan nomor bagian 103L-322-18BS. Cocok untuk kalibrasi detektor gas portabel di berbagai aplikasi industri.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa GASCO Calibration Gas: Nitrogen digunakan?

GASCO Calibration Gas: Nitrogen digunakan untuk mengkalibrasi detektor gas portabel dari berbagai merek OEM. Campuran gas ini mengandung Carbon Monoxide 100 ppm dengan akurasi +/-5%, memastikan detektor Anda memberikan pembacaan yang akurat dan andal.

Apa spesifikasi GASCO Calibration Gas: Nitrogen?

Spesifikasi GASCO Calibration Gas: Nitrogen meliputi tipe sekali pakai (disposable), akurasi +/-5%, campuran gas Carbon Monoxide 100 ppm, gas latar belakang Nitrogen, dan nomor bagian 103L-322-18BS. Produk ini kompatibel dengan semua detektor gas OEM.

Di mana beli GASCO Calibration Gas: Nitrogen di Indonesia?

Anda dapat membeli GASCO Calibration Gas: Nitrogen melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan pengiriman tepat waktu ke lokasi Anda.

Bagaimana cara memilih GASCO Calibration Gas yang tepat?

Pilih GASCO Calibration Gas: Nitrogen jika Anda memerlukan kalibrasi untuk detektor gas yang mendeteksi Carbon Monoxide. Pastikan campuran gas (100 ppm CO) dan akurasi (+/-5%) sesuai dengan kebutuhan kalibrasi peralatan Anda. Produk ini kompatibel dengan semua detektor gas OEM.

GASCO Produk

3G Electric memasok GASCO calibration gases for portable gas detectors. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Lainnya dari GASCO

Lihat semua GASCO suku cadang
This calibration gas contains hexane (C6H14) at 5,000 ppm (45% LEL) balanced in air, with +/-2% accuracy. Supplied in a 105 L cylinder, it is used to verify and calibrate portable gas detectors for combustible gas monitoring in industrial environments
GASCO
This calibration gas contains hexane (C6H14) at 5,000 ppm (45% LEL) balanced in air, with +/-2% accuracy. Supplied in a 105 L cylinder, it is used to verify and calibrate portable gas detectors for combustible gas monitoring in industrial environments
Calibration gas mixture containing 11.9% oxygen with nitrogen balance, supplied in a 105 L cylinder. Certified to ±2% accuracy for use with portable gas detectors from all OEMs. Used to verify sensor response and maintain measurement reliability in confined space entry and industrial safety monitoring
GASCO
Calibration gas mixture containing 11.9% oxygen with nitrogen balance, supplied in a 105 L cylinder. Certified to ±2% accuracy for use with portable gas detectors from all OEMs. Used to verify sensor response and maintain measurement reliability in confined space entry and industrial safety monitoring
Calibration gas mixture containing 100 ppm Refrigerant R-134A in nitrogen background, with +/-5% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors requiring R-134A sensor calibration in industrial safety applications
GASCO
Calibration gas mixture containing 100 ppm Refrigerant R-134A in nitrogen background, with +/-5% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors requiring R-134A sensor calibration in industrial safety applications
Calibration gas cylinder containing 1.5% Carbon Dioxide in Air background gas, with +/-2% accuracy. Designed for verifying and calibrating portable gas detectors in industrial safety applications. Cylinder capacity: 105 L
GASCO
Calibration gas cylinder containing 1.5% Carbon Dioxide in Air background gas, with +/-2% accuracy. Designed for verifying and calibrating portable gas detectors in industrial safety applications. Cylinder capacity: 105 L
Disposable calibration gas cylinder containing isobutylene at 950 ppm in an air background, with +/-5% accuracy. Designed for use with all OEM portable gas detectors to verify sensor response in industrial safety applications
GASCO
Disposable calibration gas cylinder containing isobutylene at 950 ppm in an air background, with +/-5% accuracy. Designed for use with all OEM portable gas detectors to verify sensor response in industrial safety applications
Disposable calibration gas mixture containing methane at 10,000 ppm with ±5% accuracy, balance nitrogen. Fitted with a CGA 600 connection for use with portable gas detectors requiring methane calibration. Suitable for verifying and adjusting sensor response in industrial safety applications
GASCO
Disposable calibration gas mixture containing methane at 10,000 ppm with ±5% accuracy, balance nitrogen. Fitted with a CGA 600 connection for use with portable gas detectors requiring methane calibration. Suitable for verifying and adjusting sensor response in industrial safety applications
This calibration gas mixture contains 19.5% oxygen with nitrogen balance, supplied in a 105 L cylinder. It is used to verify and adjust the accuracy of portable gas detectors in industrial safety applications. The gas is compatible with all OEM gas detectors
GASCO
This calibration gas mixture contains 19.5% oxygen with nitrogen balance, supplied in a 105 L cylinder. It is used to verify and adjust the accuracy of portable gas detectors in industrial safety applications. The gas is compatible with all OEM gas detectors
Refillable calibration gas mixture containing 25 ppm Azane (ammonia) in nitrogen background. Accuracy ±5%. Designed for use with all OEM portable gas detectors to verify sensor response for ammonia detection in industrial safety applications
GASCO
Refillable calibration gas mixture containing 25 ppm Azane (ammonia) in nitrogen background. Accuracy ±5%. Designed for use with all OEM portable gas detectors to verify sensor response for ammonia detection in industrial safety applications