Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

GASCO Gas Kalibrasi: Udara, Akurasi +/-2%, CO, Gas Kalibrasi, Kapasitas Silinder 105 L - Calibration Gases for Portable Gas Detectors
GASCOCalibration Gases for Portable Gas Detectors

GASCO Gas Kalibrasi: Udara, Akurasi +/-2%, CO, Gas Kalibrasi, Kapasitas Silinder 105 L

GASCO Calibration Gas: Air adalah gas kalibrasi dengan akurasi +/-2% yang dirancang untuk mengkalibrasi detektor gas portabel dari semua OEM. Produk ini berisi campuran Carbon Monoxide 800 ppm dengan gas latar…

SKU 3G-OTH-550665

Juga terdaftar sebagai: 105ES50800 · 105ES 50 800

Merek
GASCO
Item
Gas Kalibrasi: Udara, Akurasi +/-2%, CO, Gas Kalibrasi, Kapasitas Silinder 105 L
Kategori
Calibration Gases for Portable Gas Detectors
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

GASCO
Manufacturer Part Number
105ES-50-800
Type
+/-2% Accuracy, CO, Calibration Gas, Cylinder
Gas Mixture
Carbon Monoxide 800 ppm
For Use With
All OEM Gas Detectors
Background Gas
Air
Cylinder Capacity
105 L

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

GASCO Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

GASCO Calibration Gas: Air adalah gas kalibrasi dengan akurasi +/-2% yang dirancang untuk mengkalibrasi detektor gas portabel dari semua OEM. Produk ini berisi campuran Carbon Monoxide 800 ppm dengan gas latar belakang Air, tersedia dalam tabung berkapasitas 105 L dengan nomor part 105ES-50-800. Gas kalibrasi ini penting untuk memastikan keakuratan pembacaan detektor gas di lingkungan industri.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa GASCO Calibration Gas: Air digunakan?

GASCO Calibration Gas: Air digunakan untuk mengkalibrasi detektor gas portabel dari semua OEM. Gas ini berisi campuran Carbon Monoxide 800 ppm dengan gas latar belakang Air, memastikan detektor Anda memberikan pembacaan yang akurat dan sesuai standar keselamatan.

Apa spesifikasi GASCO Calibration Gas: Air?

Spesifikasi GASCO Calibration Gas: Air meliputi akurasi +/-2%, campuran gas Carbon Monoxide 800 ppm, gas latar belakang Air, kapasitas tabung 105 L, dan nomor part 105ES-50-800. Produk ini kompatibel dengan semua detektor gas OEM.

Di mana beli GASCO Calibration Gas: Air di Indonesia?

Anda dapat membeli GASCO Calibration Gas: Air melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan pengiriman lancar ke lokasi Anda.

Bagaimana cara memilih gas kalibrasi yang tepat untuk detektor gas saya?

Pilih gas kalibrasi yang sesuai dengan gas target detektor Anda. GASCO Calibration Gas: Air dengan Carbon Monoxide 800 ppm cocok untuk detektor CO. Pastikan kapasitas tabung (105 L) mencukupi untuk kebutuhan kalibrasi rutin Anda.

GASCO Produk

3G Electric memasok GASCO calibration gases for portable gas detectors. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Calibration gas mixture containing 65 ppm carbon monoxide in an air background gas, supplied in a 105 L cylinder. Designed for verifying and adjusting the accuracy of portable gas detectors in safety applications. Accuracy is ±5%
GASCO
Calibration gas mixture containing 65 ppm carbon monoxide in an air background gas, supplied in a 105 L cylinder. Designed for verifying and adjusting the accuracy of portable gas detectors in safety applications. Accuracy is ±5%
Calibration gas mixture of butane (C4H10) at 50 ppm in air, with +/-5% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors. Used to verify sensor response and calibrate instruments in industrial safety applications
GASCO
Calibration gas mixture of butane (C4H10) at 50 ppm in air, with +/-5% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors. Used to verify sensor response and calibrate instruments in industrial safety applications
Methane calibration gas cylinder with ±2% accuracy, containing 20% LEL (9,960 ppm) methane in air. 105 L capacity. Used to calibrate portable gas detectors for methane detection in hazardous environments
GASCO
Methane calibration gas cylinder with ±2% accuracy, containing 20% LEL (9,960 ppm) methane in air. 105 L capacity. Used to calibrate portable gas detectors for methane detection in hazardous environments
Calibration gas cylinder containing 0.97% propane (46% LEL) in air, with +/-2% accuracy and 105 L capacity. Used for field or bench calibration of portable gas detectors to verify and adjust sensor readings
GASCO
Calibration gas cylinder containing 0.97% propane (46% LEL) in air, with +/-2% accuracy and 105 L capacity. Used for field or bench calibration of portable gas detectors to verify and adjust sensor readings
Calibration gas mixture containing 515 ppm carbon monoxide in nitrogen, with +/-2% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors to verify and adjust sensor response to CO hazards
GASCO
Calibration gas mixture containing 515 ppm carbon monoxide in nitrogen, with +/-2% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors to verify and adjust sensor response to CO hazards
Calibration gas mixture of 225 ppm carbon monoxide in nitrogen, supplied in a 105 L cylinder with ±2% accuracy. Used for calibrating portable gas detectors from all OEM manufacturers to verify sensor response to carbon monoxide
GASCO
Calibration gas mixture of 225 ppm carbon monoxide in nitrogen, supplied in a 105 L cylinder with ±2% accuracy. Used for calibrating portable gas detectors from all OEM manufacturers to verify sensor response to carbon monoxide

Lainnya dari GASCO

Lihat semua GASCO suku cadang
Disposable calibration gas mixture containing 25 ppm hydrogen sulfide in a nitrogen background, with +/-5% accuracy. Designed for use with all OEM gas detectors to verify sensor response in confined space or industrial safety monitoring applications
GASCO
Disposable calibration gas mixture containing 25 ppm hydrogen sulfide in a nitrogen background, with +/-5% accuracy. Designed for use with all OEM gas detectors to verify sensor response in confined space or industrial safety monitoring applications
GASCO calibration gas with +/-2% accuracy, containing a Methane 4% gas mixture in a Nitrogen background. Supplied in a 105 L cylinder for use with portable gas detectors to verify and adjust sensor accuracy
GASCO
GASCO calibration gas with +/-2% accuracy, containing a Methane 4% gas mixture in a Nitrogen background. Supplied in a 105 L cylinder for use with portable gas detectors to verify and adjust sensor accuracy
Calibration gas mixture containing Pentane at 1,000 ppm in an Air background, with ±2% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors. Used to verify and adjust sensor response in industrial safety applications
GASCO
Calibration gas mixture containing Pentane at 1,000 ppm in an Air background, with ±2% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors. Used to verify and adjust sensor response in industrial safety applications
Disposable calibration gas cylinder containing a mixture of CH4/CO/N2/O2 with 500 ppm carbon monoxide in air. Provides +/-5% accuracy for verifying and calibrating portable gas detectors in industrial safety applications. Compatible with all OEM gas detectors
GASCO
Disposable calibration gas cylinder containing a mixture of CH4/CO/N2/O2 with 500 ppm carbon monoxide in air. Provides +/-5% accuracy for verifying and calibrating portable gas detectors in industrial safety applications. Compatible with all OEM gas detectors
Calibration gas mixture of 0.48% pentane (34.3% LEL) in air, supplied in a 105 L cylinder with ±2% accuracy. Used to verify and adjust the response of portable gas detectors for combustible gas monitoring in industrial safety applications
GASCO
Calibration gas mixture of 0.48% pentane (34.3% LEL) in air, supplied in a 105 L cylinder with ±2% accuracy. Used to verify and adjust the response of portable gas detectors for combustible gas monitoring in industrial safety applications
Calibration gas mixture containing 9% Carbon Dioxide in Nitrogen, with +/-2% accuracy. Supplied in a 105 L cylinder. Used for routine calibration of portable gas detectors in industrial safety applications such as confined-space entry and plant maintenance
GASCO
Calibration gas mixture containing 9% Carbon Dioxide in Nitrogen, with +/-2% accuracy. Supplied in a 105 L cylinder. Used for routine calibration of portable gas detectors in industrial safety applications such as confined-space entry and plant maintenance
Calibration gas mixture containing 50 ppm carbon monoxide in a nitrogen background, with +/-5% accuracy. Designed for use with all OEM portable gas detectors to verify sensor response in industrial safety applications such as confined-space entry and area monitoring
GASCO
Calibration gas mixture containing 50 ppm carbon monoxide in a nitrogen background, with +/-5% accuracy. Designed for use with all OEM portable gas detectors to verify sensor response in industrial safety applications such as confined-space entry and area monitoring
Disposable calibration gas mixture containing 3,500 ppm carbon dioxide with nitrogen balance. Provides ±5% accuracy for verifying and calibrating portable gas detectors in industrial safety applications
GASCO
Disposable calibration gas mixture containing 3,500 ppm carbon dioxide with nitrogen balance. Provides ±5% accuracy for verifying and calibrating portable gas detectors in industrial safety applications