GASTEC Detector Tube: GASTEC GV-100, Cl2, Gas Detection Tube, Chlorine ( Cl2 ) - Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
GASTECGas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps

GASTEC Detector Tube: GASTEC GV-100, Cl2, Gas Detection Tube, Chlorine ( Cl2 )

The GASTEC Detector Tube (MPN 8HH) is a chlorine (Cl2) gas detection tube for use with GASTEC GV-100 and GV-110 pumps. It measures chlorine concentrations from 0.25 to 10% and is supplied in a 10-pack. 3G Electric…

SKU 3G-OTH-553125

Merek
GASTEC
Item
Detector Tube: GASTEC GV-100, Cl2, Gas Detection Tube, Chlorine
Kategori
Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyur
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Spesifikasi Teknis

GASTEC
Manufacturer Part Number
8HH
Type
Cl2, Gas Detection Tube, Chlorine ( Cl2 ), With Pump, 10 PK
Gas Detected
Chlorine
Measurement Range
0.25 to 10%
Lihat Lembar Spesifikasi Lengkap

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

GASTEC Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

The GASTEC Detector Tube (MPN 8HH) is a chlorine (Cl2) gas detection tube for use with GASTEC GV-100 and GV-110 pumps. It measures chlorine concentrations from 0.25 to 10% and is supplied in a 10-pack. 3G Electric sources this genuine GASTEC product across 14 industrial departments, with specialist expertise in combustion, pumps, and controls as an authorised distributor.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

What is the GASTEC detector tube 8HH used for?

The GASTEC detector tube 8HH is used to measure chlorine (Cl2) gas concentrations in industrial environments. It works with GASTEC GV-100 and GV-110 pumps to detect chlorine from 0.25 to 10%, helping plant engineers and safety teams monitor air quality in chemical processing, water treatment, and refrigeration applications.

What are the specifications of the GASTEC 8HH chlorine tube?

The GASTEC 8HH is a chlorine (Cl2) gas detection tube with a measurement range of 0.25 to 10%. It is designed for use with GASTEC GV-100 and GV-110 pumps and is supplied in a 10-pack. The manufacturer part number is 8HH. 3G Electric sources this genuine GASTEC product for global delivery.

Where to buy GASTEC detector tube 8HH worldwide?

3G Electric supplies the genuine GASTEC detector tube 8HH worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us to order this chlorine gas detection tube for use with GASTEC GV-100 and GV-110 pumps.

How to use the GASTEC 8HH chlorine tube with a GV-100 pump?

To use the GASTEC 8HH tube, break both tips off the tube, insert it into the GASTEC GV-100 or GV-110 pump with the arrow pointing toward the pump, and pull the handle fully to draw a sample. Read the chlorine concentration directly from the tube's color change scale. Follow standard gas detection best practices for accuracy.

GASTEC Produk

3G Electric memasok GASTEC gas detection tubes for use in gastec gv-100 and gv-110 pumps. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Aksesori Pompa Katup & Regulasi Motor & Penggerak Semua Produk

Lainnya dari GASTEC

Lihat semua GASTEC suku cadang
GASTEC Detector Tube: C2H4O, Gas Detection Tube, Acetaldehyde ( C2H4O ), With Pump, 10 PK (MPN 92M). Key specifications — Gas Detected: Acetaldehyde; Measurement Range: 2.5 to 100 ppm.
GASTEC
GASTEC Detector Tube: C2H4O, Gas Detection Tube, Acetaldehyde ( C2H4O ), With Pump, 10 PK (MPN 92M). Key specifications — Gas Detected: Acetaldehyde; Measurement Range: 2.5 to 100 ppm.
GASTEC Detector Tube: HCN, Gas Detection Tube, Hydrogen Cyanide ( HCN ), 1 to 200 ppm, 10 PK (MPN 12D). Key specifications — Gas Detected: Hydrogen Cyanide; Measurement Range: 1 to 200 ppm.
GASTEC
GASTEC Detector Tube: HCN, Gas Detection Tube, Hydrogen Cyanide ( HCN ), 1 to 200 ppm, 10 PK (MPN 12D). Key specifications — Gas Detected: Hydrogen Cyanide; Measurement Range: 1 to 200 ppm.
GASTEC Detector Tube: C2H4O, Gas Detection Tube, Acetaldehyde ( C2H4O ), With Pump, 10 PK (MPN 92). Key specifications — Gas Detected: Acetaldehyde; Measurement Range: 5 to 750 ppm.
GASTEC
GASTEC Detector Tube: C2H4O, Gas Detection Tube, Acetaldehyde ( C2H4O ), With Pump, 10 PK (MPN 92). Key specifications — Gas Detected: Acetaldehyde; Measurement Range: 5 to 750 ppm.
GASTEC Detector Tube: C2H6S, Gas Detection Tube, Ethyl Mercaptan ( C2H6S ), With Pump, 10 PK (MPN 72). Key specifications — Gas Detected: Ethyl Mercaptan; Measurement Range: 0.5 to 120 ppm.
GASTEC
GASTEC Detector Tube: C2H6S, Gas Detection Tube, Ethyl Mercaptan ( C2H6S ), With Pump, 10 PK (MPN 72). Key specifications — Gas Detected: Ethyl Mercaptan; Measurement Range: 0.5 to 120 ppm.
GASTEC Detector Tube: CO, Gas Detection Tube, Carbon Monoxide ( CO ), With Pump, 5 to 100 ppm, 5 PK (MPN 1LKC). Key specifications — Gas Detected: Carbon Monoxide; Measurement Range: 5 to 100 ppm.
GASTEC
GASTEC Detector Tube: CO, Gas Detection Tube, Carbon Monoxide ( CO ), With Pump, 5 to 100 ppm, 5 PK (MPN 1LKC). Key specifications — Gas Detected: Carbon Monoxide; Measurement Range: 5 to 100 ppm.
GASTEC Detector Tube: GASTEC GV-100, C6H6, Gas Detection Tube, Benzene ( C6H6 ), With Pump, 5 PK (MPN 121L). Key specifications — Gas Detected: Benzene; Measurement Range: 0.1 to 65 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C6H6, Gas Detection Tube, Benzene ( C6H6 ), With Pump, 5 PK (MPN 121L). Key specifications — Gas Detected: Benzene; Measurement Range: 0.1 to 65 ppm.
GASTEC Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia ( NH3 ), With Pump, 10 PK (MPN 3H). Key specifications — Gas Detected: Ammonia; Measurement Range: 0.2 to 32% vol.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia ( NH3 ), With Pump, 10 PK (MPN 3H). Key specifications — Gas Detected: Ammonia; Measurement Range: 0.2 to 32% vol.
GASTEC Detector Tube: CO, Gas Detection Tube, Carbon Monoxide ( CO ), With Pump, Calibrated, 10 PK (MPN 1HH). Key specifications — Gas Detected: Carbon Monoxide; Measurement Range: 1 to 40%.
GASTEC
GASTEC Detector Tube: CO, Gas Detection Tube, Carbon Monoxide ( CO ), With Pump, Calibrated, 10 PK (MPN 1HH). Key specifications — Gas Detected: Carbon Monoxide; Measurement Range: 1 to 40%.