Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Varian FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

Varian FBR variant_2

Pembakar industri FBR GM X5/2 adalah model dual fuel gas/light-oil dua tahap (2 stages) yang dirancang untuk aplikasi ketel uap dan tungku industri. Dengan rentang daya termal 75–350 kW dan konsumsi gas G20…

SKU 3G-FBR-00183

Juga terdaftar sebagai: 00435741 · 004357 41 · 004357-41

Merek
FBR
Item
Varian FBR variant_2
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
30 kg
stage
2 stages
fuel type
Dual fuel gas/light oil
nozzle mm
250
fan motor w
450
power kw max
350
power kw min
75
ip protection
IP 40
noisiness dba
68-72
pump motor kw
180
gas consumption
7.5/15.2-35
electrical supply
1
power supply info
1N~230V 50Hz
current absorption a
0.5
thermal power mcal h
64.5/130-300
nominal electric power w
600
max combustion air temp c
50

Konten Lembar Data

DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073572_A_en GM X5/2 Dual fuel gas/light-oil burners at 2 stages. Composed by: die-cast aluminium body, high pressurisation air blower, protection cover with noise reduction plate and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train complete of: multiblock valve A class (1st stage + 2nd stage slow opening + safety), minimum gas pressure switch and stabiliser filter. Complete of flange and gasket for installation on generator, two nozzles, flexible pipes and line filter, plug/socket 7 poles. Fig. GM X5/2 TC GM X5/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073572_A_en TECHNICAL DATA MODEL GM X5/2 Thermal power min. 1°st / min. 2°st - max. 2°st * [Mcal/h] 64.5/130-300 Thermal power min. 1°st / min. 2°st - max. 2°st * [kW] 75/151-350 Gas flow G20 (NATURAL GAS) min. 1°st/min. 2°st - max. 2°st * [Nm³/h] 7.5/15.2-35 Gas flow G31 (L.P.G.) min. 1°st / min. 2°st - max. 2°st * [Nm³/h] 3/5.8-13.5 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R)B I3B/P,I3+,I3P,I3B,I3R Minimum pressure gas train D1" - S NATURAL GAS/LPG ** [mbar] 41.9/23 Minimum pressure gas train D1"1/4 - S NATURAL GAS/LPG ** [mbar] 23.7-16 Minimum pressure gas train D1"1/2 - S NATURAL GAS/LPG ** [mbar] 12.7-11.2 Maximum pressure at the entry of valves (Pe. max) 360 mbar LIGHT-OIL flow min. 1°st / min. 2°st - max. 2°st * [kg/h] 6.5/13-30 Fuel: LIGHT-OIL 1,5°E at 20°C= 6,2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) 2 stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 50 Nominal electric power [W] 600 Fan motor [W] 450 Nominal absorption fan motor [A] 3.9 Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness *** min. - max. [dB(A)] 68-72 Burner weight [kg] 30 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). GM X5/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073572_A_en OPERATING RANGE DIAGRAM [mbar] 9 8 7 6 5 4 3 2 1 0 0 50 100 150 200 250 300 350 400 [kW] Fig. X = Thermal power Y = pressure in combustion chamber The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. GM X5/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073572_A_en DIMENSIONS [MM] H S G I D RD R1 F A B TC - TL * E R2 R4 R3 C Fig. Dimensions MODEL A B C D E F G H I S R1 R2 R3 R4 RD Gas train weight GM X5/2 210 215 465 138 100 310 95 200 200 20 210 300 360 380 Rp1 6 kg TC-TL*: see chapter "FLAME TUBE LENGTH" BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. Boiler plate MODEL L min L* L max M N min N* N max GM X5/2 mm 205 220 226 M10 140 150 180 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** GM X5/2 mm 250 335 ** For different flame tube lengths, please contact our Technical-Sales Department. GM X5/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073572_A_en PRODUCT SPECIFICATION SHORT DESCRIPTION Dual fuel gas/light-oil burners at 2 stages. DETAILED SPECIFICATION Dual fuel gas/light-oil burners at 2 stages, composed by: • Die-cast aluminum body; • High pressurization air blower; • Combustion head with adjustment at high performance and elevated flame stability equipped with blast tube and flame disc; • Flange and insulating gasket for fixing at boiler; • Single-phase power supply; • Manual switch for the fuel selection gas/light-oil; • Safety air pressure switch to stop the burner in lock-out in case of failed or anomalous fan operation; • Equipped with gas train with multiblock valve A class (1st stage + 2nd stage slow opening + safety), minimum gas pressure switch and stabiliser filter; • Servomotor for air shutter and for the consent of the 2nd stage gas valve; • UV probe for flame detection; • IP 40 electric protection level. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2014/68/EU Directive M.D.; • 97/23/CE Directive P.E.D.; • 2009/142/CE Directive GAS; • Reference rules: EN676 (gas) - EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible pipes; • Line filter; • Isomart gasket; • Two nozzles; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise protection; • Antivibration couplings; • Handle gas taps. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. GM X5/2

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pembakar industri FBR GM X5/2 adalah model dual fuel gas/light-oil dua tahap (2 stages) yang dirancang untuk aplikasi ketel uap dan tungku industri. Dengan rentang daya termal 75–350 kW dan konsumsi gas G20 7,5/15,2–35 Nm³/h, unit ini dilengkapi blower bertekanan tinggi, katup multiblock kelas A, serta housing die-cast aluminium yang kompak. Cocok untuk bahan bakar gas alam (metana) atau LPG, pembakar ini juga tersedia dalam varian khusus untuk gas kota, gas batu bara, atau biogas.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi teknis burner FBR GM X5/2?

Burner FBR GM X5/2 memiliki daya termal 75–350 kW (64,5/130–300 Mcal/h), konsumsi gas G20 7,5/15,2–35 Nm³/h, dan konsumsi light-oil 6,5/13–30 kg/h. Dilengkapi motor kipas 450 W, motor pompa 180 W, proteksi IP 40, dan suplai listrik 1N~230V 50Hz.

Untuk apa burner FBR GM X5/2 digunakan?

Burner FBR GM X5/2 digunakan pada ketel uap (boiler) industri, tungku pemanas, dan sistem pembakaran lain yang memerlukan bahan bakar ganda (gas alam/LPG dan minyak ringan). Operasi dua tahap (2 stages) memungkinkan penyesuaian daya termal sesuai beban.

Apa saja komponen utama burner FBR GM X5/2?

Komponen utama meliputi bodi die-cast aluminium, blower bertekanan tinggi, katup multiblock kelas A (1st stage + 2nd stage slow opening + safety), sakelar tekanan gas minimum, filter stabiliser, dua nosel, selang fleksibel, dan flange untuk pemasangan pada generator.

Di mana beli burner FBR GM X5/2 di Indonesia?

Anda dapat membeli burner FBR GM X5/2 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai sehingga produk tiba di lokasi Anda dalam kondisi siap pakai.

Bagaimana cara memilih burner dual fuel yang tepat?

Pilih burner berdasarkan daya termal yang dibutuhkan (misal FBR GM X5/2: 75–350 kW), jenis bahan bakar (gas alam/LPG atau minyak ringan), dan tekanan gas masuk (min. 41,9 mbar untuk D1"). Pastikan juga ketersediaan suplai listrik 1N~230V 50Hz dan kondisi lingkungan operasi -15...+40°C.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
GM X5/2 TL | Variant: variant_2 | Subgroup: Burner
FBR
GM X5/2 TL | Variant: variant_2 | Subgroup: Burner
X GM X1 TC | Variant: variant_2 | Subgroup: Burner
FBR
X GM X1 TC | Variant: variant_2 | Subgroup: Burner
X GM X0 TC | Variant: variant_2 | Subgroup: Burner
FBR
X GM X0 TC | Variant: variant_2 | Subgroup: Burner
X GM X1 TL | Variant: variant_2 | Subgroup: Burner
FBR
X GM X1 TL | Variant: variant_2 | Subgroup: Burner
GM X0 TL | Variant: variant_2 | Subgroup: Burner
FBR
GM X0 TL | Variant: variant_2 | Subgroup: Burner
GM X4 TC | Variant: variant_2 | Subgroup: Burner
FBR
GM X4 TC | Variant: variant_2 | Subgroup: Burner

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL