Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

HACH Turbidity Meter, 0 to 10000 NTU, LPV444.99.00310 - Turbidity Meters
HACHTurbidity Meters

HACH Turbidity Meter, 0 to 10000 NTU, LPV444.99.00310

HACH Turbidity Meter dengan rentang pengukuran 0 hingga 10000 NTU adalah alat ukur kekeruhan presisi tinggi yang memenuhi standar EPA Method 180.1, CE, KC, dan RCM. Alat ini menawarkan akurasi kekeruhan +/-2% dari…

SKU 3G-OTH-371195

Juga terdaftar sebagai: LPV4449900310 · LPV444 99 00310 · LPV444-99-00310

Merek
HACH
Item
Turbidity Meter, 0 to 10000 NTU, LPV444.99.00310
Kategori
Turbidity Meters
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

HACH
Manufacturer Part Number
LPV444.99.00310
Type
CE/KC/Meets EPA Method 180.1/RCM
Range
0 to 10000 NTU
Includes
Oiling Cloth
Product Type
Turbidity Meter
Turbidity Accuracy
+/-2% of Reading Plus 0.01 NTU from 0 - 1000 NTU, +/-5% of Reading from 1000 - 4000 NTU +/-10% of Reading from 4000 - 10000 NTU (Ratio on)
NTU Turbidity Resolution
0

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

HACH Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

HACH Turbidity Meter dengan rentang pengukuran 0 hingga 10000 NTU adalah alat ukur kekeruhan presisi tinggi yang memenuhi standar EPA Method 180.1, CE, KC, dan RCM. Alat ini menawarkan akurasi kekeruhan +/-2% dari pembacaan ditambah 0.01 NTU pada rentang 0 - 1000 NTU, dengan resolusi NTU 0. Dilengkapi dengan oiling cloth, meteran ini ideal untuk aplikasi pengujian kualitas air di laboratorium dan industri di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi HACH Turbidity Meter LPV444.99.00310?

HACH Turbidity Meter dengan nomor bagian LPV444.99.00310 memiliki rentang pengukuran 0 hingga 10000 NTU. Akurasi kekeruhan adalah +/-2% dari pembacaan ditambah 0.01 NTU dari 0 - 1000 NTU, +/-5% dari pembacaan dari 1000 - 4000 NTU, dan +/-10% dari pembacaan dari 4000 - 10000 NTU (Ratio on). Resolusi NTU adalah 0. Alat ini memenuhi standar CE, KC, EPA Method 180.1, dan RCM.

Untuk apa HACH Turbidity Meter digunakan?

HACH Turbidity Meter digunakan untuk mengukur tingkat kekeruhan (turbidity) dalam air, dengan rentang 0 hingga 10000 NTU. Alat ini penting untuk memantau kualitas air di pengolahan air minum, air limbah, dan aplikasi industri, memastikan kepatuhan terhadap standar EPA Method 180.1.

Di mana beli HACH Turbidity Meter di Indonesia?

Anda dapat membeli HACH Turbidity Meter LPV444.99.00310 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda dengan aman.

Bagaimana cara memilih HACH Turbidity Meter yang tepat?

Pilih HACH Turbidity Meter berdasarkan rentang pengukuran yang dibutuhkan. Model LPV444.99.00310 mencakup 0 hingga 10000 NTU dengan akurasi +/-2% dari pembacaan plus 0.01 NTU pada 0 - 1000 NTU. Pastikan juga mempertimbangkan standar sertifikasi seperti EPA Method 180.1 yang relevan dengan aplikasi Anda.

Apa yang termasuk dalam paket HACH Turbidity Meter LPV444.99.00310?

Paket HACH Turbidity Meter LPV444.99.00310 mencakup satu unit meteran kekeruhan dan oiling cloth untuk perawatan. Produk ini memiliki rentang 0 hingga 10000 NTU dengan resolusi NTU 0, dan memenuhi standar CE, KC, EPA Method 180.1, serta RCM.

Digunakan dalam

Aplikasi umum untuk HACH
Municipal water treatment — HACH PHC20101 IntelliCAL pH electrode for pH monitoring in distribution systems
Industrial wastewater — HACH Chloride Test Kit (2438600) for chlorine residual analysis in effluent
Laboratory analysis — HACH Buffer Standard Solution S11M005 for calibrating pH meters in quality control labs
Environmental field testing — HACH Chemical Test Strips (2793828) for rapid water quality screening
Process water monitoring — HACH Probe LZW5056.97.0002 for ORP measurement in cooling towers
Wastewater treatment — HACH Water Quality Test Kit (2182000) for nitrite monitoring in biological treatment processes

HACH Produk

3G Electric memasok HACH turbidity meters. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Turbidity meter with a measurement range of 0 to 4000 NTU and 0 NTU resolution. Accuracy is ±2% of reading plus 0.01 NTU from 0 to 1000 NTU, and ±5% of reading from 1000 to 4000 NTU based on Formazin Primary Standard (Ratio On). Includes power supply. Complies with CE, KC, EPA Method 180.1, and RCM standards. Suitable for water clarity measurement in drinking water treatment, wastewater monitoring, and process control applications
HACH
Turbidity meter with a measurement range of 0 to 4000 NTU and 0 NTU resolution. Accuracy is ±2% of reading plus 0.01 NTU from 0 to 1000 NTU, and ±5% of reading from 1000 to 4000 NTU based on Formazin Primary Standard (Ratio On). Includes power supply. Complies with CE, KC, EPA Method 180.1, and RCM standards. Suitable for water clarity measurement in drinking water treatment, wastewater monitoring, and process control applications
Turbidity meter with a measurement range of 0 to 700 NTU/FNU/TE/F/FTU. Accuracy is ±2% plus 0.01 NTU from 0 to 40 NTU. Includes two sample vials. Used for measuring water clarity in laboratory and field applications
HACH
Turbidity meter with a measurement range of 0 to 700 NTU/FNU/TE/F/FTU. Accuracy is ±2% plus 0.01 NTU from 0 to 40 NTU. Includes two sample vials. Used for measuring water clarity in laboratory and field applications
Portable turbidity meter for measuring water clarity in field and laboratory settings. Range of 0 to 1000 NTU with accuracy of ±2% of reading plus stray light. Includes silicone oil for maintaining optical precision. Suitable for water quality monitoring and process control applications
HACH
Portable turbidity meter for measuring water clarity in field and laboratory settings. Range of 0 to 1000 NTU with accuracy of ±2% of reading plus stray light. Includes silicone oil for maintaining optical precision. Suitable for water quality monitoring and process control applications
Turbidity meter for measuring water clarity in the range of 0 to 1000 NTU. Accuracy is ±2% of reading plus stray light. Includes USB connectivity for data transfer. Suitable for water quality monitoring in treatment plants and industrial processes
HACH
Turbidity meter for measuring water clarity in the range of 0 to 1000 NTU. Accuracy is ±2% of reading plus stray light. Includes USB connectivity for data transfer. Suitable for water quality monitoring in treatment plants and industrial processes
This turbidity standard is a 100 NTU solution supplied in a 100 mL bottle. It is used for calibrating and verifying the accuracy of turbidity measurement instruments in water quality testing applications
HACH
This turbidity standard is a 100 NTU solution supplied in a 100 mL bottle. It is used for calibrating and verifying the accuracy of turbidity measurement instruments in water quality testing applications
Lab-grade turbidity standard with a concentration of 10 NTU, supplied in a 500 mL bottle. Used for calibration and verification of turbidity measurement instruments in water quality testing and environmental monitoring
HACH
Lab-grade turbidity standard with a concentration of 10 NTU, supplied in a 500 mL bottle. Used for calibration and verification of turbidity measurement instruments in water quality testing and environmental monitoring

Lainnya dari HACH

Lihat semua HACH suku cadang
Turbidity meter for measuring water clarity in applications such as drinking water treatment, wastewater monitoring, and industrial process control. Range: 0 to 10000 NTU. Accuracy: ±2% of reading plus 0.01 FNU from 0 to 1000 FNU. Includes silicone oil
HACH
Turbidity meter for measuring water clarity in applications such as drinking water treatment, wastewater monitoring, and industrial process control. Range: 0 to 10000 NTU. Accuracy: ±2% of reading plus 0.01 FNU from 0 to 1000 FNU. Includes silicone oil
The HACH 2100Q01 turbidity meter measures water clarity over a range of 0 to 1000 NTU with an accuracy of ±2% of reading plus stray light. It includes an oiling cloth for maintenance. Suitable for monitoring water quality in treatment processes and environmental testing
HACH
The HACH 2100Q01 turbidity meter measures water clarity over a range of 0 to 1000 NTU with an accuracy of ±2% of reading plus stray light. It includes an oiling cloth for maintenance. Suitable for monitoring water quality in treatment processes and environmental testing
Turbidity meter for measuring water clarity by detecting suspended particles. Range 0 to 700 NTU/FNU/TE/F/FTU with accuracy ±2% plus 0.01 NTU from 0 to 40 NTU. Includes dust cover. Used in water quality analysis for drinking water, wastewater, and industrial process monitoring
HACH
Turbidity meter for measuring water clarity by detecting suspended particles. Range 0 to 700 NTU/FNU/TE/F/FTU with accuracy ±2% plus 0.01 NTU from 0 to 40 NTU. Includes dust cover. Used in water quality analysis for drinking water, wastewater, and industrial process monitoring
Turbidity meter for measuring suspended particles in liquids, with a range of 0 to 175 EBC and accuracy of +/-2% plus 0.01 NTU from 0 to 40 NTU. Includes power supply. Commonly used in water treatment and industrial process monitoring
HACH
Turbidity meter for measuring suspended particles in liquids, with a range of 0 to 175 EBC and accuracy of +/-2% plus 0.01 NTU from 0 to 40 NTU. Includes power supply. Commonly used in water treatment and industrial process monitoring
Turbidity meter with a measurement range of 0 to 10000 NTU. Accuracy is ±2% of reading plus 0.01 FNU/NTU from 0 to 1000 FNU/NTU. Includes power cord. Used for measuring water clarity in applications such as drinking water treatment, wastewater monitoring, and industrial process control
HACH
Turbidity meter with a measurement range of 0 to 10000 NTU. Accuracy is ±2% of reading plus 0.01 FNU/NTU from 0 to 1000 FNU/NTU. Includes power cord. Used for measuring water clarity in applications such as drinking water treatment, wastewater monitoring, and industrial process control
Turbidity meter with a measurement range of 0 to 175 EBC and accuracy of ±10% of reading from 40 to 1000 NTU based on Formazin Primary Standard at 25 °C. Includes Stablcal Calibration Kit. Used for measuring water clarity in industrial and municipal applications such as wastewater treatment and process monitoring
HACH
Turbidity meter with a measurement range of 0 to 175 EBC and accuracy of ±10% of reading from 40 to 1000 NTU based on Formazin Primary Standard at 25 °C. Includes Stablcal Calibration Kit. Used for measuring water clarity in industrial and municipal applications such as wastewater treatment and process monitoring
Turbidity meter with Flow-Thru Head, Tygon Tubing, and USB Cable. CE-marked Type AB/Vial Replacement Tool for measuring water clarity in industrial and environmental applications
HACH
Turbidity meter with Flow-Thru Head, Tygon Tubing, and USB Cable. CE-marked Type AB/Vial Replacement Tool for measuring water clarity in industrial and environmental applications
Turbidity meter for measuring water clarity in the range of 0 to 1000 NTU. Provides accuracy of +/-2% of reading plus stray light. Includes power module. Suitable for field or laboratory use in water quality testing
HACH
Turbidity meter for measuring water clarity in the range of 0 to 1000 NTU. Provides accuracy of +/-2% of reading plus stray light. Includes power module. Suitable for field or laboratory use in water quality testing