HONEYWELL Calibration Gas: Nitrogen, SO2, Calibration Gas, 58 L Cylinder Capacity
The HONEYWELL Calibration Gas: Nitrogen is a calibration gas for portable gas detectors, supplied as a 58 L cylinder with a Sulfur Dioxide 5 ppm mixture in a Nitrogen background. It features a CGA C10 connection and…
SKU 3G-OTH-548958
- 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
- Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
- Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Butuh bantuan pemasangan atau rekayasa?
Ajukan pertanyaan
Deskripsi Produk
The HONEYWELL Calibration Gas: Nitrogen is a calibration gas for portable gas detectors, supplied as a 58 L cylinder with a Sulfur Dioxide 5 ppm mixture in a Nitrogen background. It features a CGA C10 connection and is identified by MPN 610-0053-000.
Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.
Pertanyaan yang Sering Diajukan
What is HONEYWELL calibration gas 610-0053-000 used for?
This HONEYWELL calibration gas is used to verify and adjust the accuracy of portable gas detectors that sense sulfur dioxide. It is supplied as a 58 L cylinder with a 5 ppm SO2 mixture in a nitrogen background, ensuring reliable calibration in industrial safety applications.
What are the specifications of HONEYWELL calibration gas 610-0053-000?
The HONEYWELL calibration gas (MPN 610-0053-000) contains 5 ppm sulfur dioxide in a nitrogen background. It has a 58 L cylinder capacity and uses a CGA C10 connection. This gas mixture is designed for calibrating portable gas detectors that measure SO2.
Where to buy HONEYWELL calibration gas 610-0053-000 worldwide?
3G Electric supplies the HONEYWELL calibration gas 610-0053-000 worldwide. We handle full logistics, customs clearance, and delivery to your facility. Contact us for a quote and lead time on this 58 L cylinder with 5 ppm SO2 in nitrogen.
How to use HONEYWELL calibration gas 610-0053-000 for detector calibration?
Attach the cylinder's CGA C10 regulator to the gas detector's calibration port. Open the valve and allow the 5 ppm SO2 mixture to flow at the rate specified by the detector manufacturer. Follow the detector's calibration procedure to adjust readings to the known gas concentration.
Digunakan dalam
Aplikasi umum untuk HONEYWELLHONEYWELL Produk
3G Electric memasok HONEYWELL calibration gases for portable gas detectors. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.




