Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

HUBBELL KILLARK LZ2SE2-32230 Fluorescent Linear Hazardous - Fluorescent Linear Hazardous Location Light Fixtures
HUBBELL KILLARKFluorescent Linear Hazardous Location Light Fixtures

HUBBELL KILLARK LZ2SE2-32230 Fluorescent Linear Hazardous

HUBBELL KILLARK LZ2SE2-32230 adalah lampu penerangan linier fluoresen untuk lokasi berbahaya dengan output 1.350 lm. Perlengkapan ini dirancang untuk area Kelas I, Div 2, Grup A, B, C, D dan beroperasi pada tegangan…

SKU 3G-OTH-387293

Juga terdaftar sebagai: LZ2SE232230 · LZ2SE2 32230

Merek
HUBBELL KILLARK
Item
LZ2SE2-32230 Fluorescent Linear Hazardous
Kategori
Fluorescent Linear Hazardous Location Light Fixtures
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

HUBBELL KILLARK
Manufacturer Part Number
LZ2SE2-32230
Type
T6 Temp Code, 65 W
AC
120/277V
Voltage
120/277V AC
For Bulb Shape
T8
Temperature Code
T6
Hazardous Location Rating
Class I, Div 2, Group A, B, C, D

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

HUBBELL KILLARK Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

HUBBELL KILLARK LZ2SE2-32230 adalah lampu penerangan linier fluoresen untuk lokasi berbahaya dengan output 1.350 lm. Perlengkapan ini dirancang untuk area Kelas I, Div 2, Grup A, B, C, D dan beroperasi pada tegangan 120/277V AC dengan daya 65 W serta kode suhu T6. Produk ini menggunakan bohlam T8 dan merupakan solusi pencahayaan andal untuk lingkungan industri yang memerlukan perlindungan ekstra.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi HUBBELL KILLARK LZ2SE2-32230?

HUBBELL KILLARK LZ2SE2-32230 memiliki output 1.350 lm, tegangan 120/277V AC, daya 65 W, kode suhu T6, dan menggunakan bohlam T8. Perlengkapan ini cocok untuk lokasi berbahaya Kelas I, Div 2, Grup A, B, C, D.

Untuk apa HUBBELL KILLARK LZ2SE2-32230 digunakan?

Lampu ini digunakan sebagai penerangan di area berbahaya seperti pabrik kimia, kilang minyak, atau fasilitas industri dengan risiko ledakan. Dengan rating Kelas I, Div 2, Grup A, B, C, D, perlengkapan ini aman untuk lingkungan yang mengandung gas atau uap mudah terbakar.

Di mana beli HUBBELL KILLARK LZ2SE2-32230 di Indonesia?

Anda dapat membeli HUBBELL KILLARK LZ2SE2-32230 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan pengiriman lancar ke lokasi Anda.

Apa arti kode suhu T6 pada HUBBELL KILLARK LZ2SE2-32230?

Kode suhu T6 pada HUBBELL KILLARK LZ2SE2-32230 menunjukkan bahwa suhu permukaan maksimum perlengkapan adalah 85°C. Ini memastikan keamanan di area dengan gas atau uap yang memiliki titik nyala rendah, sesuai standar lokasi berbahaya.

Apakah HUBBELL KILLARK LZ2SE2-32230 cocok untuk area Kelas I Div 2?

Ya, HUBBELL KILLARK LZ2SE2-32230 memiliki rating Kelas I, Div 2, Grup A, B, C, D, sehingga aman digunakan di area di mana gas atau uap mudah terbakar mungkin hadir dalam kondisi abnormal. Perlengkapan ini dirancang untuk mencegah percikan api yang dapat memicu ledakan.

Digunakan dalam

Aplikasi umum untuk HUBBELL KILLARK
Oil and gas refineries — Hubbell Killark MM-90-1WW 90° elbows for conduit routing in Class I Division 1 areas
Chemical processing plants — Hubbell Killark SWB-5 device boxes for housing switches and controls in corrosive environments
Grain handling facilities — Hubbell Killark VM1L4530 LED light fixtures for illumination in dust-ignition-proof locations
Pharmaceutical manufacturing — Hubbell Killark GECLBT-1 conduit outlet bodies for wiring connections in clean rooms with hazardous vapors
Wastewater treatment plants — Hubbell Killark GRK-537L enclosures with lens covers for instrument housing in wet hazardous zones
Petrochemical storage terminals — Hubbell Killark OLL-8M iron conduit outlet bodies for heavy-duty conduit systems in outdoor classified areas

HUBBELL KILLARK Produk

3G Electric memasok HUBBELL KILLARK fluorescent linear hazardous location light fixtures. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
This LED linear light fixture is designed for hazardous locations classified as Class I, Division 1 and 2, Groups B, C, D. It delivers 8,919 lumens at 5000K color temperature with a T6 temperature code. The fixture operates on 120/277V AC, consumes 80.4W, and is surface mounted. Suitable for industrial environments where flammable gases or vapors may be present
HUBBELL KILLARK
This LED linear light fixture is designed for hazardous locations classified as Class I, Division 1 and 2, Groups B, C, D. It delivers 8,919 lumens at 5000K color temperature with a T6 temperature code. The fixture operates on 120/277V AC, consumes 80.4W, and is surface mounted. Suitable for industrial environments where flammable gases or vapors may be present
LED linear light fixture for hazardous locations, rated Class I, Div 1 and 2, Groups B, C, D. Operates on 120/277V AC, 46.5 W, 5000K, 5598 lumens, T6 temperature code. Surface mount installation. Suitable for areas with flammable gases or vapors
HUBBELL KILLARK
LED linear light fixture for hazardous locations, rated Class I, Div 1 and 2, Groups B, C, D. Operates on 120/277V AC, 46.5 W, 5000K, 5598 lumens, T6 temperature code. Surface mount installation. Suitable for areas with flammable gases or vapors
Surface-mount LED linear light fixture rated for Class III, Div 1 and 2 hazardous locations. Operates on 120/277V AC, 46.5 W, producing 5,598 lumens at 5000K with T6 temperature code. Suitable for areas with combustible fibers or flyings
HUBBELL KILLARK
Surface-mount LED linear light fixture rated for Class III, Div 1 and 2 hazardous locations. Operates on 120/277V AC, 46.5 W, producing 5,598 lumens at 5000K with T6 temperature code. Suitable for areas with combustible fibers or flyings
Fluorescent light tank for hazardous locations, rated 84W with 4000K color temperature and T2B temperature code. Operates on 120-277V AC and measures 14 1/16 inches in length. Suspended mounting style, not color selectable. Suitable for areas where flammable gases, vapors, or combustible dusts may be present
HUBBELL KILLARK
Fluorescent light tank for hazardous locations, rated 84W with 4000K color temperature and T2B temperature code. Operates on 120-277V AC and measures 14 1/16 inches in length. Suspended mounting style, not color selectable. Suitable for areas where flammable gases, vapors, or combustible dusts may be present
LED linear light fixture for hazardous locations rated Class II, Div 1 and 2, Groups E, F, G. Operates at 120/277V AC, 28 W, 5000K color temperature, T5 temperature code. Surface mount, 3 ft length, 3321 lumens output. Suitable for areas with combustible dusts
HUBBELL KILLARK
LED linear light fixture for hazardous locations rated Class II, Div 1 and 2, Groups E, F, G. Operates at 120/277V AC, 28 W, 5000K color temperature, T5 temperature code. Surface mount, 3 ft length, 3321 lumens output. Suitable for areas with combustible dusts
This LED linear light fixture is designed for hazardous locations classified as Class I, Division 2, Groups A, B, C, D. It delivers 7,064 lumens at 5000K color temperature, operates on 120/277V AC, and consumes 60 W. The fixture has a T5 temperature code, is surface-mounted, and measures 3 ft in length. Suitable for environments where flammable gases or vapors may be present
HUBBELL KILLARK
This LED linear light fixture is designed for hazardous locations classified as Class I, Division 2, Groups A, B, C, D. It delivers 7,064 lumens at 5000K color temperature, operates on 120/277V AC, and consumes 60 W. The fixture has a T5 temperature code, is surface-mounted, and measures 3 ft in length. Suitable for environments where flammable gases or vapors may be present

Lainnya dari HUBBELL KILLARK

Lihat semua HUBBELL KILLARK suku cadang
Fluorescent linear light fixture rated for Class I, Division 2, Groups A, B, C, D hazardous locations. Operates on 120/277V AC, uses T8 bulbs, and carries a T6 temperature code. Suitable for areas where flammable gases or vapors may be present
HUBBELL KILLARK
Fluorescent linear light fixture rated for Class I, Division 2, Groups A, B, C, D hazardous locations. Operates on 120/277V AC, uses T8 bulbs, and carries a T6 temperature code. Suitable for areas where flammable gases or vapors may be present
Fluorescent linear light fixture for hazardous locations rated Class I, Division 2, Groups A, B, C, D. Operates at 120/277V AC, uses T8 bulbs, and has a T6 temperature code with 65 W power consumption. Suitable for areas where flammable gases or vapors may be present
HUBBELL KILLARK
Fluorescent linear light fixture for hazardous locations rated Class I, Division 2, Groups A, B, C, D. Operates at 120/277V AC, uses T8 bulbs, and has a T6 temperature code with 65 W power consumption. Suitable for areas where flammable gases or vapors may be present
Fluorescent linear fixture rated for Class III, Div 1 and 2 hazardous locations. Operates on 120/277V AC, uses T5HO bulbs, and has a T5 temperature code. Suitable for areas with combustible fibers or flyings
HUBBELL KILLARK
Fluorescent linear fixture rated for Class III, Div 1 and 2 hazardous locations. Operates on 120/277V AC, uses T5HO bulbs, and has a T5 temperature code. Suitable for areas with combustible fibers or flyings