Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

Pembakar industri FBR K 4/2 EVO 2 adalah pembakar dual fuel gas/light-oil dua tahap yang dirancang untuk aplikasi ketel uap dan tungku industri. Dengan rentang daya termal 116–523 kW, konsumsi gas G20 11,7/23,4–52,6…

SKU 3G-FBR-00150

Juga terdaftar sebagai: 00402451 · 004024 51 · 004024-51

Merek
FBR
Item
variant_2
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
45 kg
stage
2 stages
fuel type
Dual fuel gas/light oil
nozzle mm
250
fan motor w
550
power kw max
523
power kw min
116
ip protection
IP 40
noisiness dba
73-76
pump motor kw
180
gas consumption
11.7/23.4-52.6
electrical supply
3
power supply info
3~400V, 1/N~230V-50Hz
current absorption a
0.5
thermal power mcal h
100/200-450
nominal electric power w
800
max combustion air temp c
60

Konten Lembar Data

DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073516_D_en DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES K 4/2 EVO 2 Dual fuel gas/light-oil burners at 2 stages. Composed with: aluminum body, air blower at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the easy setting and maintenance. Available in the versions METHANE (natural gas) or G.P.L. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train composed by: one-block valve A class (1st stage + 2nd stage slow opening + safety), minimum gas pressure switch and stabiliser filter. Complete of: flange and gasket for installation on generator, nozzles, flexible hoses and line filter. Fig. 1 K 4/2 EVO 2 K 4/2 EVO 2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073516_D_en TECHNICAL DATA MODEL K 4/2 EVO 2 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 100/200-450 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 116/232-523 Gas flow G20 (NATURAL GAS) min.1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 11.7/23.4-52.6 Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 4.5/9-20.3 LIGHT-OIL flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 10/20-45 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) - I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stage Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Minimum pressure gas train D1" - S NATURAL GAS/LPG ** [mbar] 95/60 Minimum pressure gas train D1"1/4 - S NATURAL GAS/LPG ** [mbar] 54.5/44 Minimum pressure gas train D1"1/2 -S NATURAL GAS/LPG ** [mbar] 28/33 Minimum pressure gas train D2" -S NATURAL GAS/LPG ** [mbar] 26.5/33 Maximum pressure at the entry of valves (Pe. max) [mbar] 360 Nominal electric power [W] 800 Fan motor [W] 550 Fan motor current absorption [A] 1.4 Pump motor [W] 180 Pump motor current absorption [A] 0.5 Nominal auxiliary absorption [A] 0.7 Power supply: 3~400V, 1/N~230V-50Hz Electric protection degree: IP 40 Noisiness *** min. - max. [dB(A)] 73-76 Burner weight [kg] 45 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 - Control method Class 3 - Tolerance on the measured sound pressure can be assumed equal to ± 1 [dB (A)]). K 4/2 EVO 2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073516_D_en OPERATING RANGE DIAGRAM [mbar] ϵ͕ϱ K 4/2 EVO 2 8͕ϱ 7͕ϱ ϲ͕ϱ ϱ͕ϱ ϰ͕ϱ ϯ͕ϱ Ϯ͕ϱ ϭ͕ϱ Ϭ͕ϱ ͲϬ͕ϱ ϱϬ ϭϱϬ ϮϱϬ ϯϱϬ ϰϱϬ ϱϱϬ 6ϱϬ ΀Ŭt΁ Fig. 2 X = Thermal power Y = pressure in combustion chamber The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner bruciatore, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. K 4/2 EVO 2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073516_D_en DIMENSIONS [MM] A A R1 RD B C R2 R3 H D G TC-TL E R4 F Fig. 3 Dimensions: K 4/2 EVO 2 MODEL A B C D E F G H R1 R2 R3 R4 RD K 4/2 EVO 2 - D1" - S 190 245 385 150 100 793 416 100 193 360 418 445 Rp 1 K 4/2 EVO 2 - D1"1/4 - S 190 245 385 150 100 793 416 100 193 360 418 445 Rp 1 1/4 K 4/2 EVO 2 - D1"1/2 - S 190 245 385 150 100 793 416 100 193 360 438 445 Rp 1 1/2 K 4/2 EVO 2 - D2" - S 190 245 385 150 100 793 416 100 193 360 418 445 Rp 2 K 4/2 EVO 2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073516_D_en BOILER PLATE Fig. 4 Boiler plate MODEL L min L max M N K 4/2 EVO 2 mm 205 226 M10 160 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL* K 4/2 EVO 2 mm 250 350 * For different flame lengths, please contact our Technical-Sales Department. K 4/2 EVO 2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073516_D_en PRODUCT SPECIFICATION SHORT DESCRIPTION Dual fuel gas/light-oil burners at two stages. DETAILED SPECIFICATION Dual fuel gas/light-oil burners at two stages, composed by: • Aluminium frame; • Fan at high pressurisation; • Combustion head with adjustment at high performance and elevated flame stability equipped with blast tube and flame disc; • Flange and insulating gasket for fixing at boiler; • Three-phase power supply; • Manual switch for the fuel selection gas/light-oil; • Safety air pressure switch to stop the burner in lock-out in case of failed or anomalous fan operation; • Equipped with gas train with one-block valve A class (1st stage + 2nd stage slow opening + safety), minimum gas pressure switch and stabiliser filter; • Optional gas valve proving system VPS; • Light-oil pump activated by a dedicated motor; • Optional maximum gas pressure switch; • UV probe for flame detection; • Servomotor for air shutter and for the consent of the 2nd stage operation; • Moving shutter with total closure when idle in order to reduce at the least energy losses related to boiler cooling down; • IP 40 electric protection level. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive M.D.; • Directive P.E.D. (art.4, par.3) 2014/68/EU; • Reference rules: EN676 (gas) - EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible pipes; • Line filter; • Isomart gasket; • Nozzles; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise protection; • Antivibration couplings; • Handle gas taps. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. K 4/2 EVO 2

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pembakar industri FBR K 4/2 EVO 2 adalah pembakar dual fuel gas/light-oil dua tahap yang dirancang untuk aplikasi ketel uap dan tungku industri. Dengan rentang daya termal 116–523 kW, konsumsi gas G20 11,7/23,4–52,6 Nm³/h, dan perlindungan IP 40, unit ini cocok untuk berbagai kebutuhan pembakaran di sektor kelapa sawit, semen, dan F&B. Produk ini tersedia dalam versi gas alam (metana) atau LPG, dan dilengkapi katup gas satu blok kelas A serta nosel 250 mm.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi teknis FBR K 4/2 EVO 2?

Pembakar FBR K 4/2 EVO 2 memiliki daya termal 116–523 kW, konsumsi gas G20 11,7/23,4–52,6 Nm³/h, dan konsumsi light-oil 10/20–45 kg/h. Motor kipas 550 W, motor pompa 180 kW, suplai listrik 3~400V/1~230V-50Hz, arus 0,5 A, dan perlindungan IP 40.

Untuk apa FBR K 4/2 EVO 2 digunakan?

Pembakar ini digunakan untuk aplikasi dual fuel gas/light-oil pada ketel uap, tungku industri, dan sistem pembakaran lainnya yang memerlukan operasi dua tahap. Cocok untuk sektor kelapa sawit, semen, dan F&B di Indonesia.

Bagaimana cara memilih FBR K 4/2 EVO 2 yang tepat?

Pilih berdasarkan kebutuhan daya termal (116–523 kW), jenis bahan bakar (gas alam atau LPG), dan tekanan gas minimum (95 mbar untuk D1" gas alam). Pastikan suplai listrik sesuai (3~400V/1~230V-50Hz) dan suhu udara pembakaran maksimal 60°C.

Di mana beli FBR K 4/2 EVO 2 di Indonesia?

Anda dapat membeli FBR K 4/2 EVO 2 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Apa keunggulan FBR K 4/2 EVO 2 dibandingkan pembakar lain?

Keunggulan termasuk desain kompak dengan bodi aluminium, katup gas satu blok kelas A (buka lambat tahap 1 dan 2 + pengaman), tekanan udara tinggi, dan stabilitas nyala api tinggi. Dilengkapi flange, gasket, nosel, selang fleksibel, dan filter saluran.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
K 4/M/2 TL EL EVO 2 | Variant: variant_2 | Subgroup: Burner
FBR
K 4/M/2 TL EL EVO 2 | Variant: variant_2 | Subgroup: Burner
K 4/2 TC EVO 2 | Variant: variant_2 | Subgroup: Burner
FBR
K 4/2 TC EVO 2 | Variant: variant_2 | Subgroup: Burner
K 4/M/2 TC EL EVO 2 | Variant: variant_2 | Subgroup: Burner
FBR
K 4/M/2 TC EL EVO 2 | Variant: variant_2 | Subgroup: Burner
K X6/2 EVO TL | Variant: variant_2 | Subgroup: Burner
FBR
K X6/2 EVO TL | Variant: variant_2 | Subgroup: Burner
K X5/2 TL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/2 TL | Variant: variant_2 | Subgroup: Burner
K X6/M EVO TL | Variant: variant_2 | Subgroup: Burner
FBR
K X6/M EVO TL | Variant: variant_2 | Subgroup: Burner

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL