Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

Pembakar industri dual fuel gas/light-oil dua tahap (2 stages) dari FBR, model K X5/2, dirancang untuk aplikasi ketel uap dan peralatan pembakaran industri. Dengan daya termal 140–850 kW, konsumsi gas G20…

SKU 3G-FBR-00156

Juga terdaftar sebagai: 00411341 · 004113 41 · 004113-41

Merek
FBR
Item
variant_2
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
30 kg
stage
2 stages
fuel type
Dual fuel gas/light oil
nozzle mm
250
fan motor w
450
power kw max
850
power kw min
140
ip protection
IP 40
noisiness dba
68-72
pump motor kw
180
gas consumption
14/41.1-85.2
electrical supply
3
power supply info
1N~230V 50Hz
current absorption a
0.5
thermal power mcal h
120.4/352.6-731
nominal electric power w
600
max combustion air temp c
50

Konten Lembar Data

BRUCIATORI MISTI DI GAS/GASOLIO BISTADIO DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073516_A_gb [K X5/2] K X5/2 Dual fuel gas/light-oil burners at two stages. Composed by: aluminium frame, fan at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train complete of: one-block valve class A (1st stage + 2nd stage slow opening + safety), minimum gas pressure switch and filter-stabilizer. Complete of: flange and gasket for installation on generator, nozzles, flexible pipes and line filter. Fig. 1 K X5/2 K X5/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073516_A_gb [K X5/2] TECHNICAL DATA AND OPERATING RANGE DIAGRAM K X5/2 MODEL K X5/2 Thermal power 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 120.4/352.6-731 Thermal power 1°st. / min. 2°st. - max. 2°st. * [kW] 140/410-850 Gas flow G20 (NATURAL GAS) 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 14/41.1-85.2 Gas flow G31 (L.P.G.) 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 5.4/15.9-33 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) I3B/P,I3+,I3P,I3B,I3R Minimum pressure gas train D1" - S NATURAL GAS/LPG ** [mbar] 72/53 Minimum pressure gas train D1"1/4 - S NATURAL GAS/LPG ** [mbar] 45/34 Minimum pressure gas train D1"1/2 - S NATURAL GAS/LPG ** [mbar] 28/23 Minimum pressure gas train D2" - S NATURAL GAS/LPG ** [mbar] 33/60 Maximum pressure at the entry of valves (Pe. max) [mbar] 360 LIGHT-OIL flow 1°st. / min. 2°st. - max. 2°st. * [kg/h] 11.8/34.6-71.6 Fuel: LIGHT-OIL 1,5°E at 20°C= 6,2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 2.0 Fan motor [kW] 1.5 Nominal absorption fan motor [A] 3.2 Pump motor [kW] 0.37 Nominal absorption pump motor [A] 1.2 Power supply: 3~400V, 1/N~230V-50Hz Electric protection degree: IP 40 Burner weight [kg] 62 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). [mbar] [kW] Fig. 2 X = Thermal power Y = Pressure in combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. K X5/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073516_A_gb [K X5/2] DIMENSIONS [MM] H D R1 G S RD B C TC-TL** E R2 R4 R3 F1 - F2* Fig. 3 Dimensions: K X5/2 MODEL A B C D E F1 F2* G H I L S R1 R2 R3 R4 RD Gas train weight K X5/2 - D1"-S 300 245 388 175 122 794 1234 416 171 144 10 18 250 380 438 504 Rp1 23 kg K X5/2 - D1"1/4-S 300 245 388 175 122 794 1234 416 171 144 10 18 250 380 438 504 Rp 1 1/4 23 kg K X5/2 - D1"1/2-S 300 245 388 175 122 794 1234 416 171 144 10 18 250 380 430 520 Rp 1 1/2 25 kg K X5/2 - D2"-S 300 245 388 175 122 794 1234 416 171 144 10 18 250 380 430 520 Rp 2 25 kg F2*: Encumbrance with burner move back. TC-TL**: see chapter "FLAME TUBE LENGTH" BOILER PLATE *** Suggested dimension of connection between burner and generator. Fig. 4 Boiler plate MODEL L min L max M N min N * * * N max K X5/2 mm 310 368 M12 185 185 250 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL **** K X5/2 mm 250 315 **** For different flame lengths, please contact our Technical-Sales Department. K X5/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073516_A_gb [K X5/2] PRODUCT SPECIFICATION SHORT DESCRIPTION Dual fuel gas/light-oil burners at two stages. DETAILED SPECIFICATION Dual fuel gas/light-oil burners at two stages, composed by: • Aluminium frame; • Fan at high pressurisation; • Combustion head with adjustment at high performance and elevated flame stability equipped with blast tube and flame disc; • Flange and insulating gasket for fixing at boiler; • Three-phase power supply; • Manual switch for the fuel selection gas/light-oil; • Safety air pressure switch to stop the burner in lock-out in case of failed or anomalous fan operation; • Equipped with gas train with one-block valve class A (1st stage + 2nd stage slow opening + safety); gas pressure switch and stabilizer filter; • Gas valve proving system VPS as฀optional; • Motor dedicated for the light-oil pump; it turns on simultaneously to the ignition transformer activation; • Maximum gas pressure switch as฀optional; • UV probe for flame detection; • Supports and tierods for burner extraction; • Servomotor for air shutter and for the consent of the 2nd stage operation; • Moving shutter with total closure when idle in order to reduce at the least energy losses related to boiler cooling down; • IP 40 electric protection level. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive LVD; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive MD; • Directive PED (art.4, par.3) 2014/68/EU; • Reference rules: EN676 (gas) - EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible pipes; • Line filter; • Isomart gasket; • Nozzles; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise฀protection; • Antivibration฀couplings; • Handle฀gas฀taps. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. K X5/2

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pembakar industri dual fuel gas/light-oil dua tahap (2 stages) dari FBR, model K X5/2, dirancang untuk aplikasi ketel uap dan peralatan pembakaran industri. Dengan daya termal 140–850 kW, konsumsi gas G20 14/41.1–85.2 Nm³/h, dan pasokan listrik 1N~230V 50Hz, unit ini cocok untuk berbagai kebutuhan pembakaran di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa FBR K X5/2 digunakan?

FBR K X5/2 adalah pembakar industri dual fuel gas/light-oil dua tahap (2 stages) yang digunakan pada ketel uap, pemanas industri, dan peralatan pembakaran lainnya. Daya termalnya 140–850 kW dengan konsumsi gas G20 14/41.1–85.2 Nm³/h.

Apa spesifikasi teknis FBR K X5/2?

Spesifikasi FBR K X5/2 meliputi daya termal 140–850 kW, konsumsi gas G20 14/41.1–85.2 Nm³/h, pasokan listrik 1N~230V 50Hz, arus 0,5 A, motor kipas 450 W, motor pompa 180 kW, perlindungan IP 40, dan kebisingan 68–72 dBA.

Di mana beli FBR K X5/2 di Indonesia?

Anda dapat membeli FBR K X5/2 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Bagaimana cara memilih FBR K X5/2 untuk aplikasi saya?

Pilih FBR K X5/2 jika Anda membutuhkan pembakar dual fuel gas/light-oil dua tahap dengan daya termal 140–850 kW. Pastikan pasokan listrik 1N~230V 50Hz dan tekanan gas minimum sesuai spesifikasi (misalnya, 72 mbar untuk gas train D1").

Apakah FBR K X5/2 cocok untuk gas LPG?

Ya, FBR K X5/2 mendukung bahan bakar LPG (G31) dengan konsumsi 5,4/15,9–33 Nm³/h. Tekanan gas minimum untuk LPG adalah 53 mbar pada gas train D1"-S. Pastikan Anda menentukan versi LPG saat pemesanan.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
K X5/M/2 TC EL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/M/2 TC EL | Variant: variant_2 | Subgroup: Burner
K X5/2 TL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/2 TL | Variant: variant_2 | Subgroup: Burner
K X5/M/2 TL EL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/M/2 TL EL | Variant: variant_2 | Subgroup: Burner
K X7/2 TL | Variant: variant_2 | Subgroup: Burner
FBR
K X7/2 TL | Variant: variant_2 | Subgroup: Burner
K X7/M TL | Variant: variant_2 | Subgroup: Burner
FBR
K X7/M TL | Variant: variant_2 | Subgroup: Burner
K X6/2 EVO TL | Variant: variant_2 | Subgroup: Burner
FBR
K X6/2 EVO TL | Variant: variant_2 | Subgroup: Burner

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL