Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

Pembakar industri FBR K X6/2 EVO adalah pembakar dual fuel gas/light-oil dua tahap yang dirancang untuk aplikasi ketel uap dan peralatan pembakaran industri. Dengan daya termal maksimum 1300 kW dan konsumsi gas…

SKU 3G-FBR-00177

Juga terdaftar sebagai: 00431831 · 004318 31 · 004318-31

Merek
FBR
Item
variant_2
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
stage
2 stages
fuel type
Dual fuel gas/light oil
nozzle mm
400
fan motor w
2.2
power kw max
1300
power kw min
217
ip protection
IP 40
noisiness dba
82-83
pump motor kw
0.37
gas consumption
21.9/65.6-130.8
electrical supply
3
power supply info
3~400V, 1/N~230V-50Hz
current absorption a
1.2
thermal power mcal h
187/561-1118
nominal electric power w
3
max combustion air temp c
60

Konten Lembar Data

DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073566_B_en BRUCIATORI MISTI DI GAS/GASOLIO BISTADIO K X6/2 EVO - K X7/2 Dual fuel gas/light-oil burners at two stages. Composed by die-cast aluminum body, fan at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train with multiblock valve class A (1st stage + 2nd stage slow opening + safety),valve proving system, gas pressure switch and filter-stabilizer. Complete of: flange and gasket for installation on generator, nozzles, flexible pipes and line filter. Fig. K X6/2 EVO - K X7/2 K X6/2 EVO - K X7/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073566_B_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM K X6/2 EVO - K X7/2 MODEL K X6/2 EVO K X7/2� Thermal power 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 187/561-1118 254/765-1548 Thermal power 1°st. / min. 2°st. - max. 2°st. * [kW] 217/652-1300 295/890-1800 Gas flow G20 (NATURAL GAS) 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 21.9/65.6-130.8 29.7/89.5-181 Gas flow G31 (L.P.G.) 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 8.4/25.2-50.3 11.5/34.5-69.7 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL, I2E(R)/I3B/P,I3+,I3P,I3B,I3R Minimum pressure gas train D2" - S NATURAL GAS/LPG ** [mbar] 39.8/19 39.8/19 Maximum pressure at the entry of valves (Pe. max) [mbar] 360 360 LIGHT-OIL flow 1°st. / min. 2°st. - max. 2°st. * [kg/h] 18.5/55-110 25/75-152 Fuel: LIGHT-OIL 1,5°E at 20°C= 6,2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 Nominal electric power [kW] 3 4.5 Fan motor [kW] 2.2 4 Nominal absorption fan motor [A] 4.35 7.45 Pump motor [kW] 0.37 0.37 Nominal absorption pump motor [A] 1.2 1.2 Power supply: 3~400V, 1/N~230V-50Hz Electric protection degree: IP 40 IP 40 Noisiness *** min. - max. [dB(A)] 82-83 84.3-86.6 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - method of control Class 3 - The tollerance of the measured pressure can be taken equal to ± 1 [dB(A)]). K X6/2 EVO - K X7/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073566_B_en 16 K X6/2 EVO 14 12 10 8 6 4 2 0 0 200 400 600 800 1000 1200 1400 Fig. X = Thermal power [kW] Y = Pressure in combustion chamber [mbar] The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. 16 14 K X7/2 12 10 8 6 4 2 0 0 200 400 600 800 1000 1200 1400 1600 1800 2000 Fig. X = Thermal power [kW] Y = Pressure in combustion chamber [mbar] The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. K X6/2 EVO - K X7/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073566_B_en DIMENSIONS [MM] L I H A D A R1 S G TC-TL* E RD B C R4 R2 F1-F2 R3 Fig. Dimensions: K X6/2 EVO - K X7/2 MODEL A B C D E F1 F2** G H I L S R1 R2 R3 R4 RD Gas train weight K X6/2 EVO 320 240 402 209 148 963 1548 510 210 183 40 20 284 380 555 545 Rp2 25 kg K X7/2 320 240 398 209 148 963 1548 510 210 183 40 20 284 380 555 545 Rp2 25 kg F2*: Encumbrance with burner move back. TC-TL**: see chapter "FLAME TUBE LENGTH" BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. Boiler plate MODEL L min L max M N min N* N max K X6/2 EVO mm 340 368 M14 220 220 250 K X7/2 mm 340 368 M14 220 220 250 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL * K X6/2 EVO mm 280 ** 400 **฀With spacer. K X7/2 mm 280฀** 400 * For different flame tube lengths, please contact our Technical-Sales Department. K X6/2 EVO - K X7/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073566_B_en PRODUCT SPECIFICATION SHORT DESCRIPTION Dual fuel gas/light-oil burners at two stages. DETAILED SPECIFICATION Dual fuel gas/light-oil burners at two stages, composed by: • Die-cast aluminum body; • Fan at high pressurisation, with reverse blades for model K X6/2 EVO; • Combustion head with adjustment at high performance and elevated flame stability equipped with inox blast tube and inox flame disc; • Flange and insulating gasket for fixing at boiler; • Three-phase power supply; • Manual switch for the fuel selection gas/light-oil; • Safety air pressure switch to stop the burner in lock-out in case of failed or anomalous fan operation; • Complete with gas train with multiblock valve class A (1st stage + 2nd stage slow opening + safety); valve proving system, gas pressure switch and stabilizer filter; • Motor dedicated for the light-oil pump; it turns on simultaneously to the ignition transformer activation; • Maximum gas pressure switch; • UV probe for flame detection; • Supports and tierods for burner extraction; • Easy extraction of combustion head without get off the burners by bolier; • Servomotor for air shutter and for the consent of the 2nd stage operation; • Moving shutter with total closure when idle in order to reduce at the least energy losses related to boiler cooling down; • IP 40 electric protection level. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive LVD; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive MD; • Directive PED (art.4, par.3) 2014/68/EU; • Reference rules: EN676 (gas) - EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible pipes; • Line filter; • Isomart gasket; • Nozzles; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise฀protection; • Antivibration฀couplings; • Handle฀gas฀taps.…

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pembakar industri FBR K X6/2 EVO adalah pembakar dual fuel gas/light-oil dua tahap yang dirancang untuk aplikasi ketel uap dan peralatan pembakaran industri. Dengan daya termal maksimum 1300 kW dan konsumsi gas 21,9/65,6-130,8 Nm³/h, unit ini dilengkapi bodi aluminium die-cast, kipas bertekanan tinggi, dan kepala pembakaran yang dapat disetel untuk efisiensi tinggi. Produk ini cocok untuk Anda yang mencari pembakar dual fuel dengan spesifikasi 2 tahap dan daya listrik 3~400V.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi teknis FBR K X6/2 EVO?

FBR K X6/2 EVO adalah pembakar dual fuel gas/light-oil dua tahap dengan daya termal 217/652-1300 kW (1°st./min. 2°st.-max. 2°st.). Konsumsi gas G20 adalah 21,9/65,6-130,8 Nm³/h, dengan suplai listrik 3~400V, 1/N~230V-50Hz, motor kipas 2,2 kW, dan perlindungan IP 40.

Untuk apa FBR K X6/2 EVO digunakan?

Pembakar FBR K X6/2 EVO digunakan pada ketel uap industri, pemanas termal, dan peralatan pembakaran lainnya yang memerlukan bahan bakar ganda (gas alam/LPG dan minyak ringan). Produk ini beroperasi dalam dua tahap dengan rentang daya termal 217-1300 kW, cocok untuk aplikasi industri menengah hingga besar.

Apa perbedaan antara FBR K X6/2 EVO dan K X7/2?

Perbedaan utama terletak pada kapasitas daya termal. FBR K X6/2 EVO memiliki daya termal 217/652-1300 kW, sedangkan K X7/2 memiliki daya 295/890-1800 kW. Konsumsi gas G20 untuk K X6/2 EVO adalah 21,9/65,6-130,8 Nm³/h, sementara K X7/2 mencapai 29,7/89,5-181 Nm³/h.

Di mana beli FBR K X6/2 EVO di Indonesia?

Anda dapat membeli FBR K X6/2 EVO melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda. Hubungi kami untuk minta penawaran.

Bagaimana cara memilih antara FBR K X6/2 EVO dan K X7/2?

Pilih FBR K X6/2 EVO jika kebutuhan daya termal Anda berada di rentang 217-1300 kW. Jika memerlukan kapasitas lebih besar hingga 1800 kW, pilih K X7/2. Keduanya adalah pembakar dual fuel dua tahap dengan spesifikasi listrik 3~400V dan perlindungan IP 40.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
K X6/M EVO TL | Variant: variant_2 | Subgroup: Burner
FBR
K X6/M EVO TL | Variant: variant_2 | Subgroup: Burner
K X5/2 TL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/2 TL | Variant: variant_2 | Subgroup: Burner
K X7/2 TL | Variant: variant_2 | Subgroup: Burner
FBR
K X7/2 TL | Variant: variant_2 | Subgroup: Burner
K X7/M TL | Variant: variant_2 | Subgroup: Burner
FBR
K X7/M TL | Variant: variant_2 | Subgroup: Burner
K X5/M/2 TL EL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/M/2 TL EL | Variant: variant_2 | Subgroup: Burner
K 4/2 TL EVO 2 | Variant: variant_2 | Subgroup: Burner
FBR
K 4/2 TL EVO 2 | Variant: variant_2 | Subgroup: Burner

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL