Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

KDR LINE REACTORS Input Line Reactor, Low Z, 55 A, 40 hp, 460/480V AC - Input Line Reactors
KDR LINE REACTORSInput Line Reactors

KDR LINE REACTORS Input Line Reactor, Low Z, 55 A, 40 hp, 460/480V AC

KDR LINE REACTORS Input Line Reactor tipe UL Type 1 adalah reaktor input yang dirancang untuk melindungi peralatan elektronika daya dari gangguan harmonisa dan lonjakan tegangan pada sistem kelistrikan industri…

SKU 3G-OTH-622548

Merek
KDR LINE REACTORS
Item
Input Line Reactor, Low Z, 55 A, 40 hp, 460/480V AC
Part Number
KDRC1LE01
Kategori
Input Line Reactors
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

KDR LINE REACTORS
Manufacturer Part Number
KDRC1LE01
Type
Low Z, 55 A Output Current - Max
AC
460/480V
Max Output Power
40 hp

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

KDR LINE REACTORS Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

KDR LINE REACTORS Input Line Reactor tipe UL Type 1 adalah reaktor input yang dirancang untuk melindungi peralatan elektronika daya dari gangguan harmonisa dan lonjakan tegangan pada sistem kelistrikan industri. Dengan spesifikasi AC 460/480V, tipe Low Z dengan arus output maksimal 55 A, dan daya output maksimal 40 hp, produk ini cocok digunakan pada aplikasi motor listrik dan variable frequency drive (VFD) di berbagai sektor industri di Indonesia. Cari reaktor input berkualitas untuk sistem kelistrikan Anda? KDR LINE REACTORS adalah pilihan tepat.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi Input Line Reactor KDR LINE REACTORS tipe UL Type 1?

Input Line Reactor KDR LINE REACTORS tipe UL Type 1 berfungsi sebagai filter untuk mengurangi harmonisa, melindungi peralatan dari lonjakan tegangan, dan memperbaiki kualitas daya pada sistem kelistrikan. Produk ini memiliki spesifikasi AC 460/480V, tipe Low Z dengan arus output maksimal 55 A, dan daya output maksimal 40 hp.

Apa spesifikasi teknis KDR LINE REACTORS Input Line Reactor UL Type 1?

Spesifikasi teknis KDR LINE REACTORS Input Line Reactor UL Type 1 meliputi tegangan AC 460/480V, tipe Low Z, arus output maksimal 55 A, dan daya output maksimal 40 hp. Produk ini dirancang untuk aplikasi industri dengan kebutuhan proteksi harmonisa dan lonjakan tegangan.

Di mana beli KDR LINE REACTORS Input Line Reactor UL Type 1 di Indonesia?

Anda dapat membeli KDR LINE REACTORS Input Line Reactor UL Type 1 melalui 3G Electric, distributor resmi yang melayani pengiriman dan logistik ke seluruh Indonesia. Kami menangani proses bea cukai dan pengiriman langsung ke lokasi proyek Anda. Hubungi tim kami untuk informasi lebih lanjut.

Bagaimana cara memilih Input Line Reactor yang tepat untuk sistem saya?

Pemilihan Input Line Reactor bergantung pada tegangan sistem, arus beban, dan daya motor. Untuk KDR LINE REACTORS tipe UL Type 1, pastikan tegangan sistem Anda 460/480V AC, arus tidak melebihi 55 A, dan daya motor maksimal 40 hp. Konsultasikan dengan teknisi untuk memastikan kompatibilitas.

Not sure this is the right part? Photo-identify it

KDR LINE REACTORS Produk

3G Electric memasok KDR LINE REACTORS input line reactors. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
This input line reactor is rated for 460/480V AC, 50 A maximum output current, and 25 hp maximum output power. It is a Low Z type designed to protect variable frequency drives and motor controls from power line harmonics and voltage spikes. Suitable for use in industrial automation, HVAC, and pumping systems
KDR LINE REACTORS
This input line reactor is rated for 460/480V AC, 50 A maximum output current, and 25 hp maximum output power. It is a Low Z type designed to protect variable frequency drives and motor controls from power line harmonics and voltage spikes. Suitable for use in industrial automation, HVAC, and pumping systems
Open-style input line reactor rated for 460/480V AC systems with 77 A maximum output current and 60 hp maximum output power. Low impedance design for harmonic mitigation and protection of variable frequency drives in industrial motor control applications
KDR LINE REACTORS
Open-style input line reactor rated for 460/480V AC systems with 77 A maximum output current and 60 hp maximum output power. Low impedance design for harmonic mitigation and protection of variable frequency drives in industrial motor control applications
Low impedance input line reactor rated for 460/480V AC with 5 A maximum output current and 3 hp maximum output power. Used to protect variable frequency drives and motor controls from power line harmonics and voltage spikes in industrial automation, HVAC, and pump systems
KDR LINE REACTORS
Low impedance input line reactor rated for 460/480V AC with 5 A maximum output current and 3 hp maximum output power. Used to protect variable frequency drives and motor controls from power line harmonics and voltage spikes in industrial automation, HVAC, and pump systems
Open-style input line reactor rated for 460/480V AC systems with 45 A maximum output current and 30 hp maximum output power. Low impedance design for harmonic mitigation and transient protection in variable frequency drive and motor controller applications
KDR LINE REACTORS
Open-style input line reactor rated for 460/480V AC systems with 45 A maximum output current and 30 hp maximum output power. Low impedance design for harmonic mitigation and transient protection in variable frequency drive and motor controller applications
Open-style low impedance input line reactor rated for 575/600V AC, 480 A maximum output current, and 500 hp maximum output power. Used to protect variable frequency drives and motor systems from power line harmonics, voltage spikes, and current distortion in industrial automation, HVAC, and pump applications
KDR LINE REACTORS
Open-style low impedance input line reactor rated for 575/600V AC, 480 A maximum output current, and 500 hp maximum output power. Used to protect variable frequency drives and motor systems from power line harmonics, voltage spikes, and current distortion in industrial automation, HVAC, and pump applications
Open-style input line reactor rated for 460/480V AC systems with a maximum output current of 150 A and maximum output power of 100 hp. Provides impedance to reduce harmonics and voltage spikes in industrial power systems, protecting variable frequency drives and motors
KDR LINE REACTORS
Open-style input line reactor rated for 460/480V AC systems with a maximum output current of 150 A and maximum output power of 100 hp. Provides impedance to reduce harmonics and voltage spikes in industrial power systems, protecting variable frequency drives and motors

Lainnya dari KDR LINE REACTORS

Lihat semua KDR LINE REACTORS suku cadang
Open-style input line reactor rated for 460/480V AC with a maximum output current of 240 A and maximum output power of 200 hp. Provides high impedance to reduce harmonics, limit inrush current, and smooth voltage spikes in motor drive systems. Suitable for use with variable frequency drives and other industrial equipment requiring input line reactance
KDR LINE REACTORS
Open-style input line reactor rated for 460/480V AC with a maximum output current of 240 A and maximum output power of 200 hp. Provides high impedance to reduce harmonics, limit inrush current, and smooth voltage spikes in motor drive systems. Suitable for use with variable frequency drives and other industrial equipment requiring input line reactance
Open-style low-impedance input line reactor rated for 575/600V AC, 125 A maximum output current, and 125 hp maximum output power. Designed for three-phase industrial power systems to protect variable frequency drives and motor controllers from power line disturbances, reduce harmonics, limit inrush current, and smooth voltage spikes
KDR LINE REACTORS
Open-style low-impedance input line reactor rated for 575/600V AC, 125 A maximum output current, and 125 hp maximum output power. Designed for three-phase industrial power systems to protect variable frequency drives and motor controllers from power line disturbances, reduce harmonics, limit inrush current, and smooth voltage spikes
Open-style low impedance input line reactor rated for 575/600V AC, 192 A maximum output current, and 200 hp maximum output power. Used to protect variable frequency drives and motor systems from power line harmonics, voltage spikes, and current distortion in industrial automation, HVAC, pumping, and material handling applications
KDR LINE REACTORS
Open-style low impedance input line reactor rated for 575/600V AC, 192 A maximum output current, and 200 hp maximum output power. Used to protect variable frequency drives and motor systems from power line harmonics, voltage spikes, and current distortion in industrial automation, HVAC, pumping, and material handling applications
Low impedance input line reactor rated for 460/480V AC with 0.5 hp max output power and 9.7 W watts loss. Used to protect variable frequency drives and motor systems from power line disturbances, reduce harmonics, limit inrush current, and smooth voltage spikes in industrial machinery
KDR LINE REACTORS
Low impedance input line reactor rated for 460/480V AC with 0.5 hp max output power and 9.7 W watts loss. Used to protect variable frequency drives and motor systems from power line disturbances, reduce harmonics, limit inrush current, and smooth voltage spikes in industrial machinery
This input line reactor is designed for use with variable frequency drives and motor systems to mitigate harmonics, voltage spikes, and current distortion. It is a Low Z type with a maximum output power of 60 hp, rated for 208/240V AC, and has a watts loss of 209 W. The UL Type 1 enclosure allows for general-purpose indoor installation
KDR LINE REACTORS
This input line reactor is designed for use with variable frequency drives and motor systems to mitigate harmonics, voltage spikes, and current distortion. It is a Low Z type with a maximum output power of 60 hp, rated for 208/240V AC, and has a watts loss of 209 W. The UL Type 1 enclosure allows for general-purpose indoor installation
Low-impedance open-style input line reactor for 208/240V AC systems. Rated 211 A maximum output current and 75 hp maximum output power. Used to mitigate harmonics, reduce voltage spikes, and smooth current draw in motor drive applications
KDR LINE REACTORS
Low-impedance open-style input line reactor for 208/240V AC systems. Rated 211 A maximum output current and 75 hp maximum output power. Used to mitigate harmonics, reduce voltage spikes, and smooth current draw in motor drive applications
KDR LINE REACTORS
KDR LINE REACTORS
This input line reactor is a High Z type rated for 575/600V AC with a maximum output power of 1500 hp and 2985 W watts loss. It is used to protect variable frequency drives and motor systems from power line disturbances, harmonics, and voltage spikes in industrial applications such as pumps, conveyors, and compressors
This input line reactor is a High Z unit rated for 460/480V AC with a maximum output power of 5.5 hp and 66.3 W watts loss. It is designed to protect variable frequency drives and motor systems from power line harmonics, voltage spikes, and current surges. Typical applications include industrial automation, HVAC, and pump systems where power quality improvement is required
KDR LINE REACTORS
This input line reactor is a High Z unit rated for 460/480V AC with a maximum output power of 5.5 hp and 66.3 W watts loss. It is designed to protect variable frequency drives and motor systems from power line harmonics, voltage spikes, and current surges. Typical applications include industrial automation, HVAC, and pump systems where power quality improvement is required