Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

KDR LINE REACTORS Output Load Reactor, Ultra Low Z, 480V AC, 40 hp, 114 W - Output Load Reactors
KDR LINE REACTORSOutput Load Reactors

KDR LINE REACTORS Output Load Reactor, Ultra Low Z, 480V AC, 40 hp, 114 W

KDR LINE REACTORS Output Line Reactor tipe UL Type 1 adalah reaktor keluaran (output load reactor) yang dirancang untuk aplikasi industri dengan tegangan masukan 480V AC dan daya keluaran maksimal 40 hp. Dengan…

SKU 3G-OTH-723395

Merek
KDR LINE REACTORS
Item
Output Load Reactor, Ultra Low Z, 480V AC, 40 hp, 114 W
Kategori
Output Load Reactors
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

KDR LINE REACTORS
Manufacturer Part Number
KDRULC1PE01
Type
Ultra Low Z
AC
480V
Watts Loss
114 W
Input Voltage
480V AC
Max Output Power
40 hp

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

KDR LINE REACTORS Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

KDR LINE REACTORS Output Line Reactor tipe UL Type 1 adalah reaktor keluaran (output load reactor) yang dirancang untuk aplikasi industri dengan tegangan masukan 480V AC dan daya keluaran maksimal 40 hp. Dengan spesifikasi Ultra Low Z dan rugi daya hanya 114 W, komponen ini ideal untuk melindungi peralatan pembakaran dan sistem motor listrik dari gangguan harmonisa. Cari suku cadang pembakar atau reaktor berkualitas? Produk ini tersedia sebagai bagian dari solusi peralatan industri Anda.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi KDR LINE REACTORS Output Line Reactor tipe UL Type 1?

Reaktor ini berfungsi sebagai pelindung keluaran pada sistem penggerak motor (variable frequency drive) dengan meredam harmonisa dan lonjakan tegangan. Spesifikasinya meliputi tegangan masukan 480V AC, daya maksimal 40 hp, tipe Ultra Low Z, dan rugi daya 114 W. Cocok untuk aplikasi pembakar industri dan peralatan listrik berat.

Apa spesifikasi teknis KDR LINE REACTORS Output Line Reactor UL Type 1?

Spesifikasi produk ini adalah: tegangan AC 480V, tipe Ultra Low Z, rugi daya 114 W, tegangan masukan 480V AC, dan daya keluaran maksimal 40 hp. Nomor komponen pabrikan adalah KDRULC1PE01. Produk ini dirancang untuk aplikasi industri yang memerlukan perlindungan harmonisa pada sistem motor.

Di mana beli KDR LINE REACTORS Output Line Reactor UL Type 1 di Indonesia?

Anda dapat membeli KDR LINE REACTORS Output Line Reactor UL Type 1 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai sehingga Anda dapat fokus pada operasional pabrik. Hubungi kami untuk minta penawaran.

Bagaimana cara memilih output line reactor yang tepat untuk sistem 480V AC?

Pilih reaktor dengan tegangan masukan sesuai sistem Anda, yaitu 480V AC, dan daya keluaran yang mencukupi beban motor, misalnya 40 hp. Tipe Ultra Low Z seperti KDRULC1PE01 memberikan impedansi rendah untuk efisiensi tinggi. Pastikan rugi daya (114 W) sesuai dengan toleransi termal sistem Anda.

KDR LINE REACTORS Produk

3G Electric memasok KDR LINE REACTORS output load reactors. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Lainnya dari KDR LINE REACTORS

Lihat semua KDR LINE REACTORS suku cadang
Output load reactor for variable frequency drives and motors, reducing voltage spikes and harmonics. Ultra low impedance design. Rated 480V AC, 20 hp max output power, 79 W power loss
KDR LINE REACTORS
Output load reactor for variable frequency drives and motors, reducing voltage spikes and harmonics. Ultra low impedance design. Rated 480V AC, 20 hp max output power, 79 W power loss
Ultra low impedance output load reactor for motor drive protection. Rated 480V AC input, 250 A max output current, 200 hp max output power. Open-style construction. Used to reduce voltage spikes, harmonic distortion, and motor heating in variable frequency drive applications
KDR LINE REACTORS
Ultra low impedance output load reactor for motor drive protection. Rated 480V AC input, 250 A max output current, 200 hp max output power. Open-style construction. Used to reduce voltage spikes, harmonic distortion, and motor heating in variable frequency drive applications
Ultra low impedance output load reactor for variable frequency drive and motor protection. Rated 45 A continuous output current, 575V AC input voltage, and 40 hp maximum output power. Open-style construction. Used in industrial motor control systems to mitigate voltage spikes and harmonics
KDR LINE REACTORS
Ultra low impedance output load reactor for variable frequency drive and motor protection. Rated 45 A continuous output current, 575V AC input voltage, and 40 hp maximum output power. Open-style construction. Used in industrial motor control systems to mitigate voltage spikes and harmonics
This output load reactor is designed for use with variable frequency drives and motors to mitigate voltage spikes and harmonics. It features an Ultra Low Z design, rated for 50 hp maximum output power and 575/600V AC input voltage, with 123 W watts loss. Suitable for industrial applications such as pumps, conveyors, and HVAC systems
KDR LINE REACTORS
This output load reactor is designed for use with variable frequency drives and motors to mitigate voltage spikes and harmonics. It features an Ultra Low Z design, rated for 50 hp maximum output power and 575/600V AC input voltage, with 123 W watts loss. Suitable for industrial applications such as pumps, conveyors, and HVAC systems
Ultra low impedance output load reactor for motor drive applications. Rated 575V AC input, 80 A max output current, 75 hp max output power. Open-style construction. Used to reduce voltage spikes, harmonics, and motor heating in variable frequency drive systems
KDR LINE REACTORS
Ultra low impedance output load reactor for motor drive applications. Rated 575V AC input, 80 A max output current, 75 hp max output power. Open-style construction. Used to reduce voltage spikes, harmonics, and motor heating in variable frequency drive systems
Open-style output load reactor with ultra low impedance design. Rated for 480V AC input, 200 A maximum output current, and 150 hp maximum output power. Used to protect variable-frequency drives and motors from voltage spikes and harmonics, reducing reflected wave stress on long cable runs in motor-drive applications
KDR LINE REACTORS
Open-style output load reactor with ultra low impedance design. Rated for 480V AC input, 200 A maximum output current, and 150 hp maximum output power. Used to protect variable-frequency drives and motors from voltage spikes and harmonics, reducing reflected wave stress on long cable runs in motor-drive applications
Ultra low impedance output load reactor for variable frequency drive and motor protection. Rated 480V AC, 600 A maximum output current, 450 hp maximum output power. Open-style construction for panel or enclosure mounting. Reduces voltage spikes and harmonics in motor drive systems
KDR LINE REACTORS
Ultra low impedance output load reactor for variable frequency drive and motor protection. Rated 480V AC, 600 A maximum output current, 450 hp maximum output power. Open-style construction for panel or enclosure mounting. Reduces voltage spikes and harmonics in motor drive systems
Output load reactor for motor-drive applications, rated 30 hp at 480V AC with 105 W power loss. Ultra Low Z design reduces voltage spikes and harmonics. UL Type 1 enclosure
KDR LINE REACTORS
Output load reactor for motor-drive applications, rated 30 hp at 480V AC with 105 W power loss. Ultra Low Z design reduces voltage spikes and harmonics. UL Type 1 enclosure