Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

MSA ALTAIR 4XR/5X Replacement Sensor - MSA Replacement Sensors
MSAMSA Replacement Sensors

MSA ALTAIR 4XR/5X Replacement Sensor

Sensor pengganti MSA untuk detektor gas ALTAIR 4XR dan ALTAIR 5X ini dirancang untuk mendeteksi Karbon Monoksida (CO) dengan rentang pengukuran Hidrogen Sulfida (0 hingga 200 ppm). Dengan nomor komponen 10121214…

SKU 3G-OTH-554430

Merek
MSA
Item
ALTAIR 4XR/5X Replacement Sensor
Kategori
MSA Replacement Sensors
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

MSA
Manufacturer Part Number
10121214
Type
MSA, Carbon Monoxide/Hydrogen/Hydrogen Sulfide, 4 yr
Part Type
Sensor
Gas Detected
Carbon Monoxide
Series [NEW]
ALTAIR 5X
Measurement Range
Hydrogen Sulfide (0 to 200 ppm)
Compatible Detector Model/Series
ALTAIR 4XR

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

MSA Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Sensor pengganti MSA untuk detektor gas ALTAIR 4XR dan ALTAIR 5X ini dirancang untuk mendeteksi Karbon Monoksida (CO) dengan rentang pengukuran Hidrogen Sulfida (0 hingga 200 ppm). Dengan nomor komponen 10121214, sensor ini memiliki masa pakai 4 tahun dan merupakan komponen penting untuk memastikan keandalan sistem deteksi gas di lingkungan industri Anda.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa sensor MSA 10121214 digunakan?

Sensor MSA 10121214 digunakan sebagai sensor pengganti pada detektor gas ALTAIR 4XR dan ALTAIR 5X untuk mendeteksi gas Karbon Monoksida (CO) dengan rentang pengukuran Hidrogen Sulfida (0 hingga 200 ppm). Sensor ini memiliki masa pakai 4 tahun.

Apa spesifikasi sensor MSA 10121214?

Sensor MSA 10121214 adalah sensor pengganti untuk detektor gas ALTAIR 4XR dan ALTAIR 5X. Gas yang dideteksi adalah Karbon Monoksida (CO) dengan rentang pengukuran Hidrogen Sulfida (0 hingga 200 ppm). Masa pakai sensor adalah 4 tahun.

Di mana beli sensor MSA ALTAIR 4XR di Indonesia?

Anda dapat membeli sensor MSA ALTAIR 4XR (nomor komponen 10121214) melalui 3G Electric. Kami adalah distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia, menangani logistik dan bea cukai untuk Anda.

Bagaimana cara memilih sensor pengganti MSA yang tepat?

Pastikan nomor komponen (10121214) sesuai dengan model detektor Anda, yaitu ALTAIR 4XR atau ALTAIR 5X. Periksa juga gas yang ingin dideteksi (Karbon Monoksida) dan rentang pengukuran Hidrogen Sulfida (0 hingga 200 ppm) serta masa pakai sensor 4 tahun.

Digunakan dalam

Aplikasi umum untuk MSA
Chemical processing plants — MSA Advantage 3100 series with OV/P100 cartridges for organic vapor and particulate protection
HVAC maintenance — MSA infrared refrigerant leak detector (H3015-8001) for detecting R-401A leaks in commercial systems
Firefighting departments — MSA fire helmets with carved eagle front holders (MPN 10065952) for department identification
Refrigeration service — MSA heated diode leak detector (H0019-8038) for R-12 refrigerant leak detection in older systems
Industrial safety compliance — MSA gas mask canisters (NIOSH P100) for use in confined space entry with organic vapors

MSA Produk

3G Electric memasok MSA msa replacement sensors. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Lainnya dari MSA

Lihat semua MSA suku cadang
Replacement oxygen sensor for MSA Solaris-series gas detectors. Measures oxygen concentration from 0 to 25% volume. Designed for direct compatibility with Solaris detectors, with a 2-year operational lifespan. Used in industrial safety applications for monitoring oxygen levels in confined spaces and process areas
MSA
Replacement oxygen sensor for MSA Solaris-series gas detectors. Measures oxygen concentration from 0 to 25% volume. Designed for direct compatibility with Solaris detectors, with a 2-year operational lifespan. Used in industrial safety applications for monitoring oxygen levels in confined spaces and process areas
Replacement hydrogen sulfide sensor for MSA ALTAIR 2X gas detectors. Measures H2S concentrations from 0 to 200 ppm. Compatible with ALTAIR 2X series instruments. Used for personal safety monitoring in environments where toxic hydrogen sulfide gas may be present
MSA
Replacement hydrogen sulfide sensor for MSA ALTAIR 2X gas detectors. Measures H2S concentrations from 0 to 200 ppm. Compatible with ALTAIR 2X series instruments. Used for personal safety monitoring in environments where toxic hydrogen sulfide gas may be present
Replacement chlorine sensor for MSA ALTAIR 5X gas detectors. Measures chlorine concentrations from 0 to 10 ppm. Compatible with ALTAIR 5X series. Used in industrial environments where chlorine gas may be present, such as water treatment and chemical processing
MSA
Replacement chlorine sensor for MSA ALTAIR 5X gas detectors. Measures chlorine concentrations from 0 to 10 ppm. Compatible with ALTAIR 5X series. Used in industrial environments where chlorine gas may be present, such as water treatment and chemical processing
Replacement nitrogen dioxide sensor for MSA ALTAIR 4XR and ALTAIR 5X gas detectors. Measures NO₂ from 0 to 50 ppm with a 15-second response time. Used in industrial safety applications such as chemical plants, refineries, and confined-space entry to detect toxic gas exposure
MSA
Replacement nitrogen dioxide sensor for MSA ALTAIR 4XR and ALTAIR 5X gas detectors. Measures NO₂ from 0 to 50 ppm with a 15-second response time. Used in industrial safety applications such as chemical plants, refineries, and confined-space entry to detect toxic gas exposure
Replacement oxygen sensor for MSA ALTAIR 5X gas detectors. Measures oxygen concentration from 0 to 30% by volume. Used in industrial environments to monitor oxygen levels for safety
MSA
Replacement oxygen sensor for MSA ALTAIR 5X gas detectors. Measures oxygen concentration from 0 to 30% by volume. Used in industrial environments to monitor oxygen levels for safety
This MSA replacement sensor detects hydrogen sulfide (0 to 200 ppm) and sulfur dioxide. It has a 15-second response time and is designed for use with the ALTAIR 4XR gas detector, also compatible with the ALTAIR 5X. Typical applications include industrial safety monitoring for toxic gas hazards in confined spaces and process areas
MSA
This MSA replacement sensor detects hydrogen sulfide (0 to 200 ppm) and sulfur dioxide. It has a 15-second response time and is designed for use with the ALTAIR 4XR gas detector, also compatible with the ALTAIR 5X. Typical applications include industrial safety monitoring for toxic gas hazards in confined spaces and process areas
Replacement sensor for MSA ALTAIR 5X gas detectors. Detects carbon monoxide (0 to 1,999 ppm) and hydrogen sulfide. Response time: 15 seconds. Used for personal safety monitoring in industrial environments where toxic gas exposure may occur
MSA
Replacement sensor for MSA ALTAIR 5X gas detectors. Detects carbon monoxide (0 to 1,999 ppm) and hydrogen sulfide. Response time: 15 seconds. Used for personal safety monitoring in industrial environments where toxic gas exposure may occur
This MSA replacement sensor detects hydrogen sulfide (H2S) in the range of 0 to 100 ppm with a response time of 15 seconds. It is designed for use with the ALTAIR 4XR gas detector series. Typical applications include industrial safety monitoring in environments where H2S may be present
MSA
This MSA replacement sensor detects hydrogen sulfide (H2S) in the range of 0 to 100 ppm with a response time of 15 seconds. It is designed for use with the ALTAIR 4XR gas detector series. Typical applications include industrial safety monitoring in environments where H2S may be present