Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Gambar tidak tersedia
MYERSGeneral Purpose Sewage Ejector Pumps

MYERS Sewage Ejector Pump: Cast Iron, Single Phase, 1 hp, 230V AC, 2 in Max. Dia. Solids

The MYERS Sewage Ejector Pump (MPN 26089D022) is a general purpose sewage ejector pump with a cast iron construction. It is a single-phase, 1 hp unit rated for 230V AC, featuring a ductile iron impeller and a…

SKU 3G-OTH-85314

Merek
MYERS
Item
Sewage Ejector Pump: Cast Iron, Single Phase, 1 hp, 230V AC, 2 in Max. Dia. Solids
Kategori
General Purpose Sewage Ejector Pumps
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyur
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Spesifikasi Teknis

MYERS
Manufacturer Part Number
26089D022
Type
Single Phase, 1 hp
AC
230V
FNPT
2 in
Switch
Not Included
Rated Voltage
230V AC
Max. Dia. Solids
2 in
Impeller Material
Ductile Iron
Discharge Orientation
Vertical
Hazardous Location Class
Not Rated
Lihat Lembar Spesifikasi Lengkap

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

MYERS Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

The MYERS Sewage Ejector Pump (MPN 26089D022) is a general purpose sewage ejector pump with a cast iron construction. It is a single-phase, 1 hp unit rated for 230V AC, featuring a ductile iron impeller and a vertical discharge orientation with a 2 in FNPT connection. This pump handles solids up to 2 in diameter and is not rated for hazardous locations; switch is not included.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

What is the MYERS Sewage Ejector Pump used for?

The MYERS Sewage Ejector Pump (MPN 26089D022) is designed for general purpose sewage and wastewater removal in residential and light commercial applications. It handles solids up to 2 inches in diameter, making it suitable for pumping effluent from basements, septic systems, and sump pits where gravity drainage is not possible.

What are the specifications of the MYERS Sewage Ejector Pump 26089D022?

This MYERS pump is a single-phase, 1 hp unit rated for 230V AC. It features a cast iron construction, ductile iron impeller, vertical discharge orientation, and a 2 in FNPT connection. It handles solids up to 2 in diameter, is not rated for hazardous locations, and does not include a switch.

Where to buy the MYERS Sewage Ejector Pump worldwide?

3G Electric supplies the MYERS Sewage Ejector Pump (MPN 26089D022) worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time; we source and deliver this MYERS pump to any country.

How to install a MYERS Sewage Ejector Pump?

Install the MYERS pump in a sump basin with a vertical discharge pipe connected to the 2 in FNPT outlet. Ensure the pump is submerged and secured. Wire the 230V AC single-phase motor per local codes. Since the switch is not included, install a separate control float switch. Always follow the manufacturer's manual for safe operation.

Digunakan dalam

Aplikasi umum untuk MYERS
Residential basement drainage — MYERS submersible sump pump MSCI33V10 with vertical float switch
Commercial sewage lift stations — MYERS sewage ejector pump MW50-11P-01 handling 2-inch solids
Gray water effluent removal — MYERS effluent pump ME45MC-11 with cast-iron impeller
Emergency floodwater dewatering — MYERS utility pump MUFKP40 with 25-foot cloth hose
High-temperature effluent transfer — MYERS high-temp rated pump S50HTPC1 for hot water applications
Pre-assembled sewage ejector systems — MYERS simplex system SR1830-23-2-01 with 30-gallon basin

MYERS Produk

3G Electric memasok MYERS general purpose sewage ejector pumps. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Aksesori Pompa Katup & Regulasi Motor & Penggerak Semua Produk

Produk serupa

Dicocokkan berdasarkan spesifikasi dan deskripsi
U.S. MOTORS Pump Motor: 160L Frame Size, Rigid Base, Open Drip Proof, 20 hp, 230/460V AC, 3,465 RPM (MPN E40S1BZ). Key specifications — Full Load Amps @ 60 Hz: 105.0/52.0 A; Brand: U.S. MOTORS; Frame Size: 160L; Nameplate Voltage @ 60 Hz: 230/460V AC; Nameplate RPM @ 60 Hz: 3,465 RPM; Motor Enclosure: ODP.
U.S. MOTORS
U.S. MOTORS Pump Motor: 160L Frame Size, Rigid Base, Open Drip Proof, 20 hp, 230/460V AC, 3,465 RPM (MPN E40S1BZ). Key specifications — Full Load Amps @ 60 Hz: 105.0/52.0 A; Brand: U.S. MOTORS; Frame Size: 160L; Nameplate Voltage @ 60 Hz: 230/460V AC; Nameplate RPM @ 60 Hz: 3,465 RPM; Motor Enclosure: ODP.
U.S. MOTORS Pump Motor: 160L Frame Size, Rigid Base, Totally Enclosed Non-Ventilated, 20 hp, 575V AC (MPN E50S1GZ). Key specifications — Full Load Amps @ 60 Hz: 51.0 A; Brand: U.S. MOTORS; Frame Size: 160L; Nameplate Voltage @ 60 Hz: 575V AC; Nameplate RPM @ 60 Hz: 3,460 RPM; Motor Enclosure: TENV.
U.S. MOTORS
U.S. MOTORS Pump Motor: 160L Frame Size, Rigid Base, Totally Enclosed Non-Ventilated, 20 hp, 575V AC (MPN E50S1GZ). Key specifications — Full Load Amps @ 60 Hz: 51.0 A; Brand: U.S. MOTORS; Frame Size: 160L; Nameplate Voltage @ 60 Hz: 575V AC; Nameplate RPM @ 60 Hz: 3,460 RPM; Motor Enclosure: TENV.
U.S. MOTORS Pump Motor: 160ZBS Frame Size, Rigid Base, Totally Enclosed Non-Ventilated, 20 hp (MPN EZ30S1BZ). Key specifications — Full Load Amps @ 60 Hz: 84.0/42.0-36.0 A; Brand: U.S. MOTORS; Frame Size: 160ZBS; Nameplate Voltage @ 60 Hz: 230/460V AC; Nameplate RPM @ 60 Hz: 3,460 RPM; Motor Enclosure: TENV.
U.S. MOTORS
U.S. MOTORS Pump Motor: 160ZBS Frame Size, Rigid Base, Totally Enclosed Non-Ventilated, 20 hp (MPN EZ30S1BZ). Key specifications — Full Load Amps @ 60 Hz: 84.0/42.0-36.0 A; Brand: U.S. MOTORS; Frame Size: 160ZBS; Nameplate Voltage @ 60 Hz: 230/460V AC; Nameplate RPM @ 60 Hz: 3,460 RPM; Motor Enclosure: TENV.
U.S. MOTORS Pump Motor: 160L Frame Size, Rigid Base, Totally Enclosed Non-Ventilated, 20 hp, 575V AC (MPN E40S1GZ). Key specifications — Full Load Amps @ 60 Hz: 42.0 A; Brand: U.S. MOTORS; Frame Size: 160L; Nameplate Voltage @ 60 Hz: 575V AC; Nameplate RPM @ 60 Hz: 3,460 RPM; Motor Enclosure: TENV.
U.S. MOTORS
U.S. MOTORS Pump Motor: 160L Frame Size, Rigid Base, Totally Enclosed Non-Ventilated, 20 hp, 575V AC (MPN E40S1GZ). Key specifications — Full Load Amps @ 60 Hz: 42.0 A; Brand: U.S. MOTORS; Frame Size: 160L; Nameplate Voltage @ 60 Hz: 575V AC; Nameplate RPM @ 60 Hz: 3,460 RPM; Motor Enclosure: TENV.
U.S. MOTORS Pump Motor: 160ZBS Frame Size, Rigid Base, Totally Enclosed Non-Ventilated, 20 hp (MPN EZ25S1BZ). Key specifications — Full Load Amps @ 60 Hz: 69.0/35.0-28.3 A; Brand: U.S. MOTORS; Frame Size: 160ZBS; Nameplate Voltage @ 60 Hz: 230/460V AC; Nameplate RPM @ 60 Hz: 3,440/3,470 RPM; Motor Enclosure: TENV.
U.S. MOTORS
U.S. MOTORS Pump Motor: 160ZBS Frame Size, Rigid Base, Totally Enclosed Non-Ventilated, 20 hp (MPN EZ25S1BZ). Key specifications — Full Load Amps @ 60 Hz: 69.0/35.0-28.3 A; Brand: U.S. MOTORS; Frame Size: 160ZBS; Nameplate Voltage @ 60 Hz: 230/460V AC; Nameplate RPM @ 60 Hz: 3,440/3,470 RPM; Motor Enclosure: TENV.
U.S. MOTORS Pump Motor: 160ZBS Frame Size, Rigid Base, Totally Enclosed Non-Ventilated, 20 hp (MPN EZ25S1GZ). Key specifications — Full Load Amps @ 60 Hz: 27.5 A; Brand: U.S. MOTORS; Frame Size: 160ZBS; Nameplate Voltage @ 60 Hz: 575V AC; Nameplate RPM @ 60 Hz: 3,430/3,460 RPM; Motor Enclosure: TENV.
U.S. MOTORS
U.S. MOTORS Pump Motor: 160ZBS Frame Size, Rigid Base, Totally Enclosed Non-Ventilated, 20 hp (MPN EZ25S1GZ). Key specifications — Full Load Amps @ 60 Hz: 27.5 A; Brand: U.S. MOTORS; Frame Size: 160ZBS; Nameplate Voltage @ 60 Hz: 575V AC; Nameplate RPM @ 60 Hz: 3,430/3,460 RPM; Motor Enclosure: TENV.

Lainnya dari MYERS

Lihat semua MYERS suku cadang
MYERS
MYERS
MYERS Sewage Ejector Pump: Cast Iron, Single Phase, 2 hp, 230V AC, 2 in Max. Dia. Solids, 2 in FNPT (MPN 26089D034). Key specifications — Impeller Material: Ductile Iron; Rated Voltage: 230V AC; Hazardous Location Class: Not Rated; Brand: MYERS; Discharge Orientation: Vertical; Switch: Not Included.
MYERS
MYERS
MYERS Sewage Ejector Pump: Cast Iron, Single Phase, 1/2 hp, 230V AC, 130 gpm Flow Rate @ 10' of Head (MPN 26089D014). Key specifications — Impeller Material: Ductile Iron; Rated Voltage: 230V AC; Hazardous Location Class: Not Rated; Brand: MYERS; Discharge Orientation: Vertical; Switch: Piggyback Tether Float.
MYERS Sewage Ejector Pump: Cast Iron, Single Phase, 1/2 hp, 115V AC, 133 gpm Flow Rate @ 10' of Head (MPN MW50-11P-01). Key specifications — Impeller Material: Thermoplastic; Rated Voltage: 115V AC; Hazardous Location Class: Not Rated; Brand: MYERS; Discharge Orientation: Vertical; Switch: Piggyback Tether Float.
MYERS
MYERS Sewage Ejector Pump: Cast Iron, Single Phase, 1/2 hp, 115V AC, 133 gpm Flow Rate @ 10' of Head (MPN MW50-11P-01). Key specifications — Impeller Material: Thermoplastic; Rated Voltage: 115V AC; Hazardous Location Class: Not Rated; Brand: MYERS; Discharge Orientation: Vertical; Switch: Piggyback Tether Float.
MYERS Sewage Ejector Pump: Cast Iron, Single Phase, 1/2 hp, 230V AC, 133 gpm Flow Rate @ 10' of Head (MPN MW50-21-01). Key specifications — Impeller Material: Thermoplastic; Rated Voltage: 230V AC; Hazardous Location Class: Not Rated; Brand: MYERS; Discharge Orientation: Vertical; Switch: Not Included.
MYERS
MYERS Sewage Ejector Pump: Cast Iron, Single Phase, 1/2 hp, 230V AC, 133 gpm Flow Rate @ 10' of Head (MPN MW50-21-01). Key specifications — Impeller Material: Thermoplastic; Rated Voltage: 230V AC; Hazardous Location Class: Not Rated; Brand: MYERS; Discharge Orientation: Vertical; Switch: Not Included.
MYERS
MYERS
MYERS Sewage Ejector Pump: Cast Iron, Single Phase, 1 1/2 hp, 230V AC, 2 in Max. Dia. Solids, 12.8 A (MPN 26089D028). Key specifications — Impeller Material: Ductile Iron; Rated Voltage: 230V AC; Hazardous Location Class: Not Rated; Brand: MYERS; Discharge Orientation: Vertical; Switch: Not Included.