Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Parker 07F46AC Compressed Air Filter, 3/4 in NPT, 40 Micron, 145 cfm, 150 psi - Parker FRL Air Filters
ParkerParker FRL Air Filters

Parker 07F46AC Compressed Air Filter, 3/4 in NPT, 40 Micron, 145 cfm, 150 psi

PARKER Compressed Air Filter: Particulate adalah filter udara tekan tipe partikulat dari Parker yang dirancang untuk menyaring kontaminan pada sistem pneumatik industri. Filter ini memiliki ukuran port NPT 3/4 in…

SKU 3G-OTH-153136

Merek
Parker
Item
07F46AC Compressed Air Filter, 3/4 in NPT, 40 Micron, 145 cfm, 150 psi
Part Number
07F46AC
Kategori
Parker FRL Air Filters
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Compliance & shipping

Hazardous material
Not classified as hazardous
California Prop 65 warning
No warning recorded
Licence required
No licence required
Safety Data Sheet
Not available
Special shipping
Ships under standard freight

Spesifikasi Teknis

Parker
Manufacturer Part Number
07F46AC
Series
07F
Type
40 micron, 145 cfm
Edge
or
Chrome
.
UNSPSC
40161505
Mfr. Model
07F46AC
Overall Depth
3-1/4
Pressure Drop
5
Air Inlet Size
3/4
Overall Height
7-11/16
Air Outlet Size
3/4
Max Op Pressure
150 psi
Maximum Flow Rate
145
Number of Air Inlets
1
Number of Air Outlets
1
Browser upgrade required.
After December 31, 2024, you risk losing access to OEM.com using your current browser. Upgrade to

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Parker Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

PARKER Compressed Air Filter: Particulate adalah filter udara tekan tipe partikulat dari Parker yang dirancang untuk menyaring kontaminan pada sistem pneumatik industri. Filter ini memiliki ukuran port NPT 3/4 in, tipe 40 micron dengan kapasitas aliran 145 cfm, dan tekanan operasi maksimum 150 psi. Dengan nomor komponen 07F46AC, produk ini cocok untuk aplikasi yang memerlukan perlindungan terhadap partikel pada saluran udara tekan.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi filter udara tekan Parker 07F46AC?

Filter udara tekan Parker 07F46AC memiliki ukuran port NPT 3/4 in, tipe 40 micron dengan kapasitas aliran 145 cfm, dan tekanan operasi maksimum 150 psi. Produk ini merupakan filter partikulat dari Parker yang cocok untuk sistem pneumatik industri.

Untuk apa filter partikulat Parker 07F46AC digunakan?

Filter partikulat Parker 07F46AC digunakan untuk menyaring partikel kontaminan pada saluran udara tekan, seperti debu, kotoran, dan partikel padat lainnya. Filter ini membantu melindungi komponen pneumatik seperti katup, silinder, dan alat pneumatik dari kerusakan akibat kontaminasi.

Di mana beli filter udara tekan Parker 07F46AC di Indonesia?

Anda dapat membeli filter udara tekan Parker 07F46AC melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda dengan aman.

Bagaimana cara memilih filter udara tekan yang tepat?

Pilih filter udara tekan berdasarkan ukuran port, tingkat filtrasi (micron), kapasitas aliran (cfm), dan tekanan operasi maksimum. Untuk aplikasi umum, filter 40 micron seperti Parker 07F46AC dengan NPT 3/4 in dan tekanan 150 psi cocok untuk sistem pneumatik standar.

Digunakan dalam

Aplikasi umum untuk Parker
Injection molding machine proportional directional control — Parker solenoid coils and proportional valve cartridges for mold-closing and hydraulic actuation circuits
Construction equipment hydraulic steering and boom control — Parker directional control valves with solenoid actuation for excavator and loader hydraulic systems
Industrial press forming systems — Parker pressure-relief and proportional directional valves for tonnage control and cycle sequencing
Material-handling conveyor systems — Parker proportional control valves with solenoid pilot stages for smooth load acceleration and deceleration
Tire-building machinery — Parker solenoid-actuated directional cartridges for synchronized multi-axis hydraulic positioning
Forestry and mobile equipment — Parker valve spools and solenoid assemblies rated for harsh-environment hydraulic circuits and mobile-duty pressure cycling
Not sure this is the right part? Photo-identify it

Parker Produk

3G Electric memasok Parker parker frl air filters. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Parker 07F series compressed air particulate filter with 3/4 in NPT connections. Removes solid contaminants down to 40 micron at 145 cfm flow capacity, with a maximum operating pressure of 150 psi. Used in compressed air systems to protect downstream pneumatic equipment from dirt and pipe scale
Parker
Parker 07F series compressed air particulate filter with 3/4 in NPT connections. Removes solid contaminants down to 40 micron at 145 cfm flow capacity, with a maximum operating pressure of 150 psi. Used in compressed air systems to protect downstream pneumatic equipment from dirt and pipe scale
Particulate filter for compressed air systems with 1/2 in NPT connection. Removes solid contaminants down to 40 micron at 130 cfm flow capacity. Maximum operating pressure of 150 psi. Suitable for general-purpose filtration in pneumatic lines
Parker
Particulate filter for compressed air systems with 1/2 in NPT connection. Removes solid contaminants down to 40 micron at 130 cfm flow capacity. Maximum operating pressure of 150 psi. Suitable for general-purpose filtration in pneumatic lines
Parker 06F36AC particulate filter for compressed air systems, with 1/2 in NPT connection, 40 micron filtration, 85 cfm flow capacity, and 150 psi maximum operating pressure. Removes solid contaminants such as dirt, rust, and pipe scale from compressed air lines
Parker
Parker 06F36AC particulate filter for compressed air systems, with 1/2 in NPT connection, 40 micron filtration, 85 cfm flow capacity, and 150 psi maximum operating pressure. Removes solid contaminants such as dirt, rust, and pipe scale from compressed air lines
Particulate filter for compressed air systems with 1/4 in NPT connection. Removes solid contaminants down to 40 micron at 53 cfm flow capacity. Maximum operating pressure 150 psi. Suitable for general-purpose filtration in pneumatic circuits to protect downstream components
Parker
Particulate filter for compressed air systems with 1/4 in NPT connection. Removes solid contaminants down to 40 micron at 53 cfm flow capacity. Maximum operating pressure 150 psi. Suitable for general-purpose filtration in pneumatic circuits to protect downstream components
Particulate filter for compressed air systems. 3/8 in NPT connection, 40 micron filtration, 80 cfm flow capacity, 150 psi maximum operating pressure. Used in pneumatic circuits to remove solid contaminants from compressed air
Parker
Particulate filter for compressed air systems. 3/8 in NPT connection, 40 micron filtration, 80 cfm flow capacity, 150 psi maximum operating pressure. Used in pneumatic circuits to remove solid contaminants from compressed air
Particulate filter for compressed air systems. Removes solid contaminants down to 40 micron. 1/4 in NPT connection, 53 cfm flow capacity, maximum operating pressure 150 psi. Used in pneumatic circuits and industrial air lines to protect downstream equipment
Parker
Particulate filter for compressed air systems. Removes solid contaminants down to 40 micron. 1/4 in NPT connection, 53 cfm flow capacity, maximum operating pressure 150 psi. Used in pneumatic circuits and industrial air lines to protect downstream equipment

Lainnya dari Parker

Lihat semua Parker suku cadang
Particulate filter for compressed air systems, removing solid contaminants down to 5 micron. Features 1/2 in NPT ports, 85 cfm flow capacity, and 250 psi maximum operating pressure. Suitable for installation in industrial air lines to protect downstream pneumatic components
Parker
Particulate filter for compressed air systems, removing solid contaminants down to 5 micron. Features 1/2 in NPT ports, 85 cfm flow capacity, and 250 psi maximum operating pressure. Suitable for installation in industrial air lines to protect downstream pneumatic components
Particulate filter for compressed air systems. Removes solid contaminants down to 40 micron. 3/8 in NPT connection, 80 cfm flow capacity, maximum operating pressure 150 psi. Used to protect pneumatic components such as valves, cylinders, and tools
Parker
Particulate filter for compressed air systems. Removes solid contaminants down to 40 micron. 3/8 in NPT connection, 80 cfm flow capacity, maximum operating pressure 150 psi. Used to protect pneumatic components such as valves, cylinders, and tools
Parker coalescing filter for compressed air systems. Removes oil aerosols, water, and solid particles down to 0.01 micron. Port size 1/8 in NPT, flow capacity 17 scfm, maximum operating pressure 150 psig. Features a plastic bowl and Auto Pulse Drain. Suitable for pneumatic controls, instrumentation, and painting applications
Parker
Parker coalescing filter for compressed air systems. Removes oil aerosols, water, and solid particles down to 0.01 micron. Port size 1/8 in NPT, flow capacity 17 scfm, maximum operating pressure 150 psig. Features a plastic bowl and Auto Pulse Drain. Suitable for pneumatic controls, instrumentation, and painting applications
Parker coalescing filter for compressed air systems. Removes oil aerosols, water, and solid contaminants down to 0.01 micron. Features 1/4 in NPT port, 20 scfm flow capacity, 150 psig maximum operating pressure, Twist Drain, and plastic bowl. Suitable for applications requiring clean, dry air such as instrumentation and pneumatic controls
Parker
Parker coalescing filter for compressed air systems. Removes oil aerosols, water, and solid contaminants down to 0.01 micron. Features 1/4 in NPT port, 20 scfm flow capacity, 150 psig maximum operating pressure, Twist Drain, and plastic bowl. Suitable for applications requiring clean, dry air such as instrumentation and pneumatic controls
Particulate filter for compressed air systems with 1/2 in NPT connection. Removes solid contaminants such as dirt and pipe scale at 40 micron filtration. Rated for 130 cfm flow and 150 psi maximum operating pressure. Suitable for general-purpose filtration in pneumatic lines to protect downstream components
Parker
Particulate filter for compressed air systems with 1/2 in NPT connection. Removes solid contaminants such as dirt and pipe scale at 40 micron filtration. Rated for 130 cfm flow and 150 psi maximum operating pressure. Suitable for general-purpose filtration in pneumatic lines to protect downstream components
Particulate filter for compressed air systems with 1/8 in NPT ports, 5 micron filtration, 22 scfm flow capacity, and 250 psig maximum operating pressure. Features a metal bowl and Twist Drain for easy maintenance. Removes solid contaminants to protect downstream pneumatic components
Parker
Particulate filter for compressed air systems with 1/8 in NPT ports, 5 micron filtration, 22 scfm flow capacity, and 250 psig maximum operating pressure. Features a metal bowl and Twist Drain for easy maintenance. Removes solid contaminants to protect downstream pneumatic components
Parker 06F32AC is a particulate compressed air filter with 1/2 in NPT connections, 40 micron filtration, 85 cfm flow capacity, and 150 psi maximum operating pressure. It removes solid contaminants from compressed air systems to protect downstream pneumatic components
Parker
Parker 06F32AC is a particulate compressed air filter with 1/2 in NPT connections, 40 micron filtration, 85 cfm flow capacity, and 150 psi maximum operating pressure. It removes solid contaminants from compressed air systems to protect downstream pneumatic components
Parker 14F17AB particulate filter for compressed air systems. Features 1/4 in NPT ports, 40 micron filtration, 24 scfm flow capacity, and 250 psig maximum operating pressure. Metal bowl with Auto Pulse Drain for automatic condensate removal. Removes solid contaminants to protect downstream pneumatic equipment
Parker
Parker 14F17AB particulate filter for compressed air systems. Features 1/4 in NPT ports, 40 micron filtration, 24 scfm flow capacity, and 250 psig maximum operating pressure. Metal bowl with Auto Pulse Drain for automatic condensate removal. Removes solid contaminants to protect downstream pneumatic equipment