Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Parker High-Flow Check Valve, 3000 psi, 65 gpm, 1 1/16 in JIC 37° Flare - High-Flow Check Valves
ParkerHigh-Flow Check Valves

Parker High-Flow Check Valve, 3000 psi, 65 gpm, 1 1/16 in JIC 37° Flare

Parker Hydraulic Check Valve seri CV-750-MFMF-5 adalah katup periksa aliran tinggi (high-flow check valve) yang dirancang untuk sistem hidrolik bertekanan tinggi. Katup ini memiliki tekanan kerja maksimum 3.000 psi…

SKU 3G-OTH-186939

Juga terdaftar sebagai: CV750MFMF5 · CV 750 MFMF 5

Merek
Parker
Item
High-Flow Check Valve, 3000 psi, 65 gpm, 1 1/16 in JIC 37° Flare
Kategori
High-Flow Check Valves
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Parker
Manufacturer Part Number
CV-750-MFMF-5

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Parker Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Parker Hydraulic Check Valve seri CV-750-MFMF-5 adalah katup periksa aliran tinggi (high-flow check valve) yang dirancang untuk sistem hidrolik bertekanan tinggi. Katup ini memiliki tekanan kerja maksimum 3.000 psi, kapasitas aliran 65 gpm, dan koneksi JIC 37° Flare berukuran 1 1/16 inci. Material bodi terbuat dari baja (steel) untuk ketahanan dan keandalan di lingkungan industri berat. Cocok untuk aplikasi pembakar industri dan peralatan pembakaran yang memerlukan kontrol aliran balik yang presisi.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi Parker Hydraulic Check Valve CV-750-MFMF-5?

Parker Hydraulic Check Valve CV-750-MFMF-5 memiliki tekanan kerja maksimum 3.000 psi, kapasitas aliran 65 gpm, dan koneksi JIC 37° Flare berukuran 1 1/16 inci. Material bodi terbuat dari baja (steel). Katup ini dirancang untuk aplikasi aliran tinggi pada sistem hidrolik industri.

Untuk apa Parker Hydraulic Check Valve digunakan?

Katup periksa hidrolik Parker ini digunakan untuk mencegah aliran balik dalam sistem hidrolik bertekanan tinggi, seperti pada rangkaian gas, ketel uap, dan peralatan pembakaran. Dengan tekanan 3.000 psi dan aliran 65 gpm, katup ini cocok untuk aplikasi industri berat yang memerlukan keandalan tinggi.

Di mana beli Parker Hydraulic Check Valve di Indonesia?

Anda dapat membeli Parker Hydraulic Check Valve CV-750-MFMF-5 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda dengan aman.

Bagaimana cara memilih Parker Hydraulic Check Valve yang tepat?

Pilih katup periksa berdasarkan tekanan kerja maksimum (3.000 psi), kapasitas aliran (65 gpm), dan ukuran koneksi (1 1/16 inci JIC 37° Flare). Pastikan material bodi (baja) sesuai dengan lingkungan operasi Anda. Parker CV-750-MFMF-5 dirancang untuk aplikasi aliran tinggi pada sistem hidrolik.

Digunakan dalam

Aplikasi umum untuk Parker
Injection molding machine proportional directional control — Parker solenoid coils and proportional valve cartridges for mold-closing and hydraulic actuation circuits
Construction equipment hydraulic steering and boom control — Parker directional control valves with solenoid actuation for excavator and loader hydraulic systems
Industrial press forming systems — Parker pressure-relief and proportional directional valves for tonnage control and cycle sequencing
Material-handling conveyor systems — Parker proportional control valves with solenoid pilot stages for smooth load acceleration and deceleration
Tire-building machinery — Parker solenoid-actuated directional cartridges for synchronized multi-axis hydraulic positioning
Forestry and mobile equipment — Parker valve spools and solenoid assemblies rated for harsh-environment hydraulic circuits and mobile-duty pressure cycling

Parker Produk

3G Electric memasok Parker high-flow check valves. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Steel-bodied check valve with JIC 37° flare connections on inlet and outlet. Allows flow in one direction while preventing backflow in hydraulic systems. Suitable for high-pressure applications requiring unidirectional flow control
Parker
Steel-bodied check valve with JIC 37° flare connections on inlet and outlet. Allows flow in one direction while preventing backflow in hydraulic systems. Suitable for high-pressure applications requiring unidirectional flow control
Steel-body check valve rated for 3,000 psi and 75 gpm. Inlet connection is 1 5/16 in JIC 37° Flare; outlet is SAE O-Ring Boss. Allows flow in one direction only, preventing backflow in hydraulic systems such as industrial machinery, mobile equipment, and power units
Parker
Steel-body check valve rated for 3,000 psi and 75 gpm. Inlet connection is 1 5/16 in JIC 37° Flare; outlet is SAE O-Ring Boss. Allows flow in one direction only, preventing backflow in hydraulic systems such as industrial machinery, mobile equipment, and power units
Steel-bodied check valve with JIC 37° flare inlet and outlet connections. Allows flow in one direction only, preventing backflow in hydraulic systems. Suitable for high-pressure applications in industrial and mobile equipment
Parker
Steel-bodied check valve with JIC 37° flare inlet and outlet connections. Allows flow in one direction only, preventing backflow in hydraulic systems. Suitable for high-pressure applications in industrial and mobile equipment
Steel body check valve rated for 3,500 psi and 30 gpm. Inlet connection is 1 1/16 in JIC 37° Flare; outlet connection is SAE O-Ring Boss. Used in hydraulic systems to permit flow in one direction and prevent backflow
Parker
Steel body check valve rated for 3,500 psi and 30 gpm. Inlet connection is 1 1/16 in JIC 37° Flare; outlet connection is SAE O-Ring Boss. Used in hydraulic systems to permit flow in one direction and prevent backflow
Steel-bodied check valve for high-pressure hydraulic systems. Prevents reverse flow in circuits with JIC 37° flare connections. Rated for 2500 psi and 80 gpm. Suitable for industrial machinery and mobile equipment requiring unidirectional flow control
Parker
Steel-bodied check valve for high-pressure hydraulic systems. Prevents reverse flow in circuits with JIC 37° flare connections. Rated for 2500 psi and 80 gpm. Suitable for industrial machinery and mobile equipment requiring unidirectional flow control
Steel-bodied check valve with JIC 37° Flare connections on both inlet and outlet. Allows flow in one direction and prevents backflow in hydraulic systems. Rated for 4,500 psi and 15 gpm with a 3/4 in port size
Parker
Steel-bodied check valve with JIC 37° Flare connections on both inlet and outlet. Allows flow in one direction and prevents backflow in hydraulic systems. Rated for 4,500 psi and 15 gpm with a 3/4 in port size

Lainnya dari Parker

Lihat semua Parker suku cadang
This high-flow check valve allows fluid to flow in one direction while blocking reverse flow in hydraulic systems. Constructed of steel, it is rated for 3000 psi and 50 gpm with a 3/4 in port size featuring SAE O-Ring Boss and JIC 37° Flare connections. Used in industrial machinery, mobile equipment, and power units for reliable backflow prevention
Parker
This high-flow check valve allows fluid to flow in one direction while blocking reverse flow in hydraulic systems. Constructed of steel, it is rated for 3000 psi and 50 gpm with a 3/4 in port size featuring SAE O-Ring Boss and JIC 37° Flare connections. Used in industrial machinery, mobile equipment, and power units for reliable backflow prevention
Steel high-flow check valve rated for 3000 psi and 13 gpm. Features 9/16 in JIC 37° flare connections on both ends. Allows flow in one direction only, preventing backflow in hydraulic circuits. Suitable for use in industrial machinery, mobile equipment, and power units
Parker
Steel high-flow check valve rated for 3000 psi and 13 gpm. Features 9/16 in JIC 37° flare connections on both ends. Allows flow in one direction only, preventing backflow in hydraulic circuits. Suitable for use in industrial machinery, mobile equipment, and power units
Steel high-flow check valve rated for 3000 psi and 65 gpm. Port size is 1 1/16 in with SAE O-Ring Boss and SAE O-Ring Face Seal connections. Used in hydraulic systems to permit flow in one direction and prevent backflow
Parker
Steel high-flow check valve rated for 3000 psi and 65 gpm. Port size is 1 1/16 in with SAE O-Ring Boss and SAE O-Ring Face Seal connections. Used in hydraulic systems to permit flow in one direction and prevent backflow
Steel high-flow check valve rated for 3000 psi and 50 gpm. Features 3/4 in JIC 37° flare connections on both ends. Designed for unidirectional flow control in hydraulic systems, preventing backflow to protect pumps and actuators. Suitable for industrial machinery, mobile equipment, and hydraulic power units
Parker
Steel high-flow check valve rated for 3000 psi and 50 gpm. Features 3/4 in JIC 37° flare connections on both ends. Designed for unidirectional flow control in hydraulic systems, preventing backflow to protect pumps and actuators. Suitable for industrial machinery, mobile equipment, and hydraulic power units
Steel high-flow check valve with JIC 37° Flare connections. Rated for 3000 psi and 100 gpm with a 1 5/16 in port size. Allows flow in one direction while preventing backflow in hydraulic systems
Parker
Steel high-flow check valve with JIC 37° Flare connections. Rated for 3000 psi and 100 gpm with a 1 5/16 in port size. Allows flow in one direction while preventing backflow in hydraulic systems
Steel high-flow check valve with JIC 37° flare connections. Rated for 3000 psi and 6 gpm with a 7/16 in port size. Used in hydraulic systems to allow flow in one direction and prevent backflow
Parker
Steel high-flow check valve with JIC 37° flare connections. Rated for 3000 psi and 6 gpm with a 7/16 in port size. Used in hydraulic systems to allow flow in one direction and prevent backflow
Steel check valve rated for 3000 psi and 100 gpm. Allows flow in one direction while preventing backflow. Features SAE O-Ring Face Seal connections with 1 7/16 in port size. Suitable for hydraulic systems in industrial machinery and mobile equipment
Parker
Steel check valve rated for 3000 psi and 100 gpm. Allows flow in one direction while preventing backflow. Features SAE O-Ring Face Seal connections with 1 7/16 in port size. Suitable for hydraulic systems in industrial machinery and mobile equipment
Steel-bodied check valve rated for 3000 psi and 13 gpm. Port size 9/16 in with SAE O-Ring Boss and SAE O-Ring Face Seal connections. Allows flow in one direction and prevents backflow in hydraulic systems
Parker
Steel-bodied check valve rated for 3000 psi and 13 gpm. Port size 9/16 in with SAE O-Ring Boss and SAE O-Ring Face Seal connections. Allows flow in one direction and prevents backflow in hydraulic systems