Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Parker Spring-Loaded Check Valve - Spring-Loaded Check Valves
ParkerSpring-Loaded Check Valves

Parker Spring-Loaded Check Valve

PARKER Refrigerant Check Valve adalah katup periksa beban pegas (spring-loaded ball check valve) yang dirancang untuk sistem refrigerasi dan pendingin industri. Katup ini memiliki sambungan 7/8 in, material tembaga…

SKU 3G-OTH-74208

Juga terdaftar sebagai: CV9P14FS14FS · CV9P 14FS 14FS

Merek
Parker
Item
Spring-Loaded Check Valve
Kategori
Spring-Loaded Check Valves
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Parker
Manufacturer Part Number
CV9P-14FS-14FS
Material
Copper
Cut Out
3 1/2 in
Connections
7/8 in

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Parker Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

PARKER Refrigerant Check Valve adalah katup periksa beban pegas (spring-loaded ball check valve) yang dirancang untuk sistem refrigerasi dan pendingin industri. Katup ini memiliki sambungan 7/8 in, material tembaga, dan cut out 3 1/2 in. Produk dengan nomor bagian CV9P-14FS-14FS ini merupakan komponen penting untuk memastikan aliran refrigeran satu arah dan mencegah aliran balik dalam sistem. Sebagai distributor resmi, 3G Electric menyediakan katup periksa PARKER ini untuk kebutuhan peralatan industri di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi PARKER Refrigerant Check Valve CV9P-14FS-14FS?

PARKER Refrigerant Check Valve CV9P-14FS-14FS berfungsi sebagai katup periksa beban pegas yang memungkinkan aliran refrigeran hanya dalam satu arah. Katup ini mencegah aliran balik yang dapat merusak kompresor atau komponen sistem refrigerasi lainnya. Dengan material tembaga dan sambungan 7/8 in, katup ini cocok untuk berbagai aplikasi pendingin industri.

Apa spesifikasi PARKER Refrigerant Check Valve CV9P-14FS-14FS?

Spesifikasi PARKER Refrigerant Check Valve CV9P-14FS-14FS meliputi: merek PARKER, tipe spring-loaded ball check valve, sambungan 7/8 in, material tembaga, dan cut out 3 1/2 in. Katup ini dirancang untuk sistem refrigerasi dan pendingin, memastikan aliran satu arah yang andal.

Di mana beli PARKER Refrigerant Check Valve di Indonesia?

Anda dapat membeli PARKER Refrigerant Check Valve CV9P-14FS-14FS melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda dengan aman. Hubungi kami untuk minta penawaran.

Bagaimana cara memilih PARKER Refrigerant Check Valve yang tepat?

Untuk memilih PARKER Refrigerant Check Valve yang tepat, perhatikan spesifikasi seperti sambungan (7/8 in), material (tembaga), dan cut out (3 1/2 in) sesuai dengan sistem refrigerasi Anda. Pastikan katup beban pegas ini cocok dengan tekanan dan jenis refrigeran yang digunakan. Konsultasikan dengan teknisi atau hubungi 3G Electric untuk bantuan lebih lanjut.

Digunakan dalam

Aplikasi umum untuk Parker
Injection molding machine proportional directional control — Parker solenoid coils and proportional valve cartridges for mold-closing and hydraulic actuation circuits
Construction equipment hydraulic steering and boom control — Parker directional control valves with solenoid actuation for excavator and loader hydraulic systems
Industrial press forming systems — Parker pressure-relief and proportional directional valves for tonnage control and cycle sequencing
Material-handling conveyor systems — Parker proportional control valves with solenoid pilot stages for smooth load acceleration and deceleration
Tire-building machinery — Parker solenoid-actuated directional cartridges for synchronized multi-axis hydraulic positioning
Forestry and mobile equipment — Parker valve spools and solenoid assemblies rated for harsh-environment hydraulic circuits and mobile-duty pressure cycling

Parker Produk

3G Electric memasok Parker spring-loaded check valves. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
This Parker push-to-connect ball valve is designed for use in HVAC and refrigeration systems to control refrigerant flow. It features a 7/8" male push-to-connect fitting, an access port for service, and is A2L compatible. Rated for 870 psi, it has no relief port
Parker
This Parker push-to-connect ball valve is designed for use in HVAC and refrigeration systems to control refrigerant flow. It features a 7/8" male push-to-connect fitting, an access port for service, and is A2L compatible. Rated for 870 psi, it has no relief port
This Parker refrigerant ball valve features a 1/2 in sweat connection with copper connection material for brazing into copper tubing. It is rated for a maximum pressure of 750 psi and an operating temperature range of -40°F to 250°F. The valve includes a 1/4"-20 UNC bottom mounting thread for secure installation. Suitable for isolating or controlling refrigerant flow in HVAC and refrigeration systems
Parker
This Parker refrigerant ball valve features a 1/2 in sweat connection with copper connection material for brazing into copper tubing. It is rated for a maximum pressure of 750 psi and an operating temperature range of -40°F to 250°F. The valve includes a 1/4"-20 UNC bottom mounting thread for secure installation. Suitable for isolating or controlling refrigerant flow in HVAC and refrigeration systems
This Parker refrigerant ball valve features a 3/8 in sweat connection with copper connection material. Rated for a maximum pressure of 750 psi and an operating temperature range of -40°F to 250°F, it includes a 1/4"-20 UNC bottom mounting thread. Used for isolating or controlling refrigerant flow in HVAC and refrigeration systems, it provides service access and line shutoff
Parker
This Parker refrigerant ball valve features a 3/8 in sweat connection with copper connection material. Rated for a maximum pressure of 750 psi and an operating temperature range of -40°F to 250°F, it includes a 1/4"-20 UNC bottom mounting thread. Used for isolating or controlling refrigerant flow in HVAC and refrigeration systems, it provides service access and line shutoff
3/8" male push-to-connect refrigeration ball valve with access port, no relief port. Rated 870 psi, A2L compatible. Used to isolate refrigerant flow in HVACR systems for servicing or repairs
Parker
3/8" male push-to-connect refrigeration ball valve with access port, no relief port. Rated 870 psi, A2L compatible. Used to isolate refrigerant flow in HVACR systems for servicing or repairs
This sweat connection service valve is used in HVAC and refrigeration systems to isolate refrigerant flow for maintenance or repair. It features a 5/8 in sweat connection, copper connection material, and a 1/4"-20 UNC bottom mounting thread. Rated for maximum 750 psi and operating temperature range -40°F to 250°F
Parker
This sweat connection service valve is used in HVAC and refrigeration systems to isolate refrigerant flow for maintenance or repair. It features a 5/8 in sweat connection, copper connection material, and a 1/4"-20 UNC bottom mounting thread. Rated for maximum 750 psi and operating temperature range -40°F to 250°F
This Parker ball valve features a 1/4 in male push-to-connect fitting for quick installation in refrigeration and HVAC systems. It includes an access port for service connections and is rated for 870 psi. The valve is A2L compatible, suitable for use with low-flammability refrigerants. No relief port is provided
Parker
This Parker ball valve features a 1/4 in male push-to-connect fitting for quick installation in refrigeration and HVAC systems. It includes an access port for service connections and is rated for 870 psi. The valve is A2L compatible, suitable for use with low-flammability refrigerants. No relief port is provided

Lainnya dari Parker

Lihat semua Parker suku cadang
Spring-loaded ball check valve constructed of copper with 1/2 in connections and a 2 7/8 in cut out. Designed for one-directional flow control in refrigerant systems, preventing backflow to protect compressors and components
Parker
Spring-loaded ball check valve constructed of copper with 1/2 in connections and a 2 7/8 in cut out. Designed for one-directional flow control in refrigerant systems, preventing backflow to protect compressors and components
This spring-loaded ball check valve is constructed of copper and features 5/8 in connections with a 3 1/2 in cut out. It is used in HVAC and refrigeration systems to prevent reverse flow of refrigerant, protecting compressors and other system components from backflow damage
Parker
This spring-loaded ball check valve is constructed of copper and features 5/8 in connections with a 3 1/2 in cut out. It is used in HVAC and refrigeration systems to prevent reverse flow of refrigerant, protecting compressors and other system components from backflow damage
Spring-loaded ball check valve with copper body and 1 1/8 in connections. Designed for refrigerant systems to prevent reverse flow in liquid, suction, or hot gas lines. Features a 4 in cut out for installation
Parker
Spring-loaded ball check valve with copper body and 1 1/8 in connections. Designed for refrigerant systems to prevent reverse flow in liquid, suction, or hot gas lines. Features a 4 in cut out for installation
Spring-loaded ball check valve with copper body. Prevents reverse flow in refrigerant piping systems. Features 3/8-inch connections and 3-inch cut-out. Suitable for HVAC and refrigeration applications
Parker
Spring-loaded ball check valve with copper body. Prevents reverse flow in refrigerant piping systems. Features 3/8-inch connections and 3-inch cut-out. Suitable for HVAC and refrigeration applications