Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

REICHERT Refractometer: Specific Gravity (Urine), +/-0.005 SG (Urine), Auto, Digital - Digital Handheld Refractometers
REICHERTDigital Handheld Refractometers

REICHERT Refractometer: Specific Gravity (Urine), +/-0.005 SG (Urine), Auto, Digital

REICHERT Refractometer Digital Handheld untuk pengukuran Specific Gravity (Urine) adalah alat ukur presisi yang dirancang khusus untuk analisis urin di laboratorium klinis dan industri. Dengan spesifikasi akurasi…

SKU 3G-OTH-417018

Merek
REICHERT
Item
Refractometer: Specific Gravity
Kategori
Digital Handheld Refractometers
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyur
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Spesifikasi Teknis

REICHERT
Manufacturer Part Number
13940019
Type
+/-0.005 SG (Urine), Auto, Digital
RI
1.04
Lihat Lembar Spesifikasi Lengkap

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

REICHERT Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

REICHERT Refractometer Digital Handheld untuk pengukuran Specific Gravity (Urine) adalah alat ukur presisi yang dirancang khusus untuk analisis urin di laboratorium klinis dan industri. Dengan spesifikasi akurasi +/-0.005 SG (Urine) dan rentang indeks bias (RI) 1.04 hingga 1 RI, alat ini menawarkan pengukuran otomatis yang cepat dan andal. Sebagai bagian dari peralatan laboratorium berkualitas, REICHERT memastikan hasil yang konsisten untuk kebutuhan pengujian Anda.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi REICHERT Refractometer Specific Gravity (Urine)?

REICHERT Refractometer Digital Handheld ini memiliki spesifikasi akurasi +/-0.005 SG (Urine) dengan rentang indeks bias (RI) 1.04 hingga 1 RI. Tipe pengukuran adalah otomatis (Auto) dan digital, sehingga memudahkan pembacaan hasil tanpa interpretasi manual.

Untuk apa REICHERT Refractometer Specific Gravity (Urine) digunakan?

Alat ini digunakan untuk mengukur Specific Gravity (berat jenis) urin secara digital dan otomatis. Pengukuran ini penting dalam analisis urin untuk mendeteksi konsentrasi zat terlarut, membantu diagnosis kondisi seperti dehidrasi atau gangguan ginjal di laboratorium klinis.

Bagaimana cara memilih REICHERT Refractometer yang tepat?

Pilih REICHERT Refractometer berdasarkan parameter yang ingin diukur, seperti Specific Gravity (Urine) dengan akurasi +/-0.005 SG. Pastikan rentang RI (1.04 hingga 1 RI) sesuai dengan kebutuhan sampel Anda. Model digital otomatis ini ideal untuk laboratorium yang membutuhkan hasil cepat dan presisi.

Di mana beli REICHERT Refractometer Specific Gravity (Urine) di Indonesia?

Anda dapat membeli REICHERT Refractometer Digital Handheld ini melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda dengan aman.

Digunakan dalam

Aplikasi umum untuk REICHERT
Automotive service — REICHERT digital refractometer (model 13940017) for brake fluid boiling point testing
HVAC maintenance — REICHERT analog refractometer (model 137584L0) for ethylene glycol concentration in cooling systems
Food processing — REICHERT digital refractometer (model 13940027) for propylene glycol measurement in food-grade antifreeze
Pharmaceutical lab — REICHERT darkfield colony counter (model 13332700) for microbial colony enumeration
Chemical processing — REICHERT digital refractometer (model 13940024) for ethylene glycol freeze point monitoring
Water treatment — REICHERT digital refractometer (model 13940020) for sodium chloride specific gravity in brine solutions

REICHERT Produk

3G Electric memasok REICHERT digital handheld refractometers. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Lainnya dari REICHERT

Lihat semua REICHERT suku cadang
REICHERT Refractometer: Ethylene Glycol/Ethylene Glycol Boiling Point/Ethylene Glycol Freeze Point (MPN 13940024). Key specifications — attr1073899: REICHERT; attr1079772: +/-0.2% EG; attr1136199: 0 % Brix; attr1079778: Automatic; attr1136198: 95 % Brix; attr1079777: 0.002; attr1108250: Ethylene Glycol Boiling Point.
REICHERT
REICHERT Refractometer: Ethylene Glycol/Ethylene Glycol Boiling Point/Ethylene Glycol Freeze Point (MPN 13940024). Key specifications — attr1073899: REICHERT; attr1079772: +/-0.2% EG; attr1136199: 0 % Brix; attr1079778: Automatic; attr1136198: 95 % Brix; attr1079777: 0.002; attr1108250: Ethylene Glycol Boiling Point.
REICHERT Refractometer: Glycerin/Glycerin Boiling Point/Glycerin Freeze Point, Auto, Digital (MPN 13940023). Key specifications — attr1073899: REICHERT; attr1079772: +/-0.6°C Glycerin Boiling Point; attr1136199: 0 % Brix; attr1079778: Automatic; attr1136198: 82 % Brix; attr1079777: 0.2% Glycerine; attr1108250: Glycerin.
REICHERT
REICHERT Refractometer: Glycerin/Glycerin Boiling Point/Glycerin Freeze Point, Auto, Digital (MPN 13940023). Key specifications — attr1073899: REICHERT; attr1079772: +/-0.6°C Glycerin Boiling Point; attr1136199: 0 % Brix; attr1079778: Automatic; attr1136198: 82 % Brix; attr1079777: 0.2% Glycerine; attr1108250: Glycerin.
REICHERT Refractometer: +/-0.2% PG/+/-1.0°F PG Boiling Point/+/-1.0°F PG Freeze Point Accuracy (MPN 13940026). Key specifications — attr1073899: REICHERT; attr1079772: +/-1.0°F PG Freeze Point; attr1079778: Automatic; attr1079777: 0.002; attr1108250: Propylene Glycol.
REICHERT
REICHERT Refractometer: +/-0.2% PG/+/-1.0°F PG Boiling Point/+/-1.0°F PG Freeze Point Accuracy (MPN 13940026). Key specifications — attr1073899: REICHERT; attr1079772: +/-1.0°F PG Freeze Point; attr1079778: Automatic; attr1079777: 0.002; attr1108250: Propylene Glycol.
REICHERT Refractometer: Auto, Digital, 3 7/8 in Overall Dp, 2 1/8 in Overall Wd, 1 in Overall Ht (MPN 13940014). Key specifications — attr1073899: REICHERT; attr1079772: +/- 0.003 SG (Battery Acid); attr1136199: 1 SG; attr1079778: Automatic; attr1136198: 1.463 SG; attr1079777: 0.005; attr1108250: Specific Gravity (Battery Acid).
REICHERT
REICHERT Refractometer: Auto, Digital, 3 7/8 in Overall Dp, 2 1/8 in Overall Wd, 1 in Overall Ht (MPN 13940014). Key specifications — attr1073899: REICHERT; attr1079772: +/- 0.003 SG (Battery Acid); attr1136199: 1 SG; attr1079778: Automatic; attr1136198: 1.463 SG; attr1079777: 0.005; attr1108250: Specific Gravity (Battery Acid).
REICHERT Refractometer: Sodium Chloride (NaCI)/Sodium Chloride Specifc Gravity, Auto, Digital (MPN 13940020). Key specifications — attr1073899: REICHERT; attr1079772: +/-0.002 Sodium Chloride SG; attr1079778: Automatic; attr1079777: 0.0075; attr1108250: Sodium Chloride Specifc Gravity.
REICHERT
REICHERT Refractometer: Sodium Chloride (NaCI)/Sodium Chloride Specifc Gravity, Auto, Digital (MPN 13940020). Key specifications — attr1073899: REICHERT; attr1079772: +/-0.002 Sodium Chloride SG; attr1079778: Automatic; attr1079777: 0.0075; attr1108250: Sodium Chloride Specifc Gravity.
REICHERT Refractometer: Brix/Refractive Index, +/-0.0002% RI/+/-0.2% Brix Accuracy, Auto, Digital (MPN 13940000). Key specifications — attr1073899: REICHERT; attr1079772: +/-0.2% Brix; attr1136199: 1.333 RI; attr1079778: Automatic; attr1136198: 1.447 RI; attr1079777: 0.0001 RI; attr1108250: Refractive Index.
REICHERT
REICHERT Refractometer: Brix/Refractive Index, +/-0.0002% RI/+/-0.2% Brix Accuracy, Auto, Digital (MPN 13940000). Key specifications — attr1073899: REICHERT; attr1079772: +/-0.2% Brix; attr1136199: 1.333 RI; attr1079778: Automatic; attr1136198: 1.447 RI; attr1079777: 0.0001 RI; attr1108250: Refractive Index.
REICHERT Refractometer: Glycerin/Glycerin Boiling Point/Glycerin Freeze Point, Auto, Digital (MPN 13940022). Key specifications — attr1073899: REICHERT; attr1079772: +/-1°F Glycerin Freeze Point; attr1079778: Automatic; attr1079777: 0.2% Glycerine; attr1108250: Glycerin Boiling Point.
REICHERT
REICHERT Refractometer: Glycerin/Glycerin Boiling Point/Glycerin Freeze Point, Auto, Digital (MPN 13940022). Key specifications — attr1073899: REICHERT; attr1079772: +/-1°F Glycerin Freeze Point; attr1079778: Automatic; attr1079777: 0.2% Glycerine; attr1108250: Glycerin Boiling Point.
REICHERT Refractometer: Ethylene Glycol/Ethylene Glycol Boiling Point/Ethylene Glycol Freeze Point (MPN 13940025). Key specifications — attr1073899: REICHERT; attr1079772: +/-0.2% EG; attr1136199: 0 % Brix; attr1079778: Automatic; attr1136198: 95 % Brix; attr1079777: 0.002; attr1108250: Ethylene Glycol Freeze Point.
REICHERT
REICHERT Refractometer: Ethylene Glycol/Ethylene Glycol Boiling Point/Ethylene Glycol Freeze Point (MPN 13940025). Key specifications — attr1073899: REICHERT; attr1079772: +/-0.2% EG; attr1136199: 0 % Brix; attr1079778: Automatic; attr1136198: 95 % Brix; attr1079777: 0.002; attr1108250: Ethylene Glycol Freeze Point.