From the manufacturer's datasheet

Pactrol
Supply voltage
220 V +10% -15%, single phase
Frequency
50 Hz
Motor rating
220 V, 4 A
Ignition transformer rating
220 V, 2 A
Signaling rating
220 V, 2 A
Minimum cell illumination
15 Lux
Max ambient temperature (equipment)
50 °C
Max ambient temperature (cell)
70 °C
Features
  • Pre-ventilation time approx. 15 sec.
  • Pre-ignition time approx. 15 sec.
  • Delay between first and second stage approx. 30 sec.
  • Post-ignition time 2 sec.
  • Safety time 10 sec.
  • Power consumption in normal operation 6 VA
Typical applications
For two-stage burnersUsed with flame cell types 8208 or 8209
Use only in single-phase 220 V supply with +10% -15% tolerance.
Ensure minimum cell illumination of 15 Lux.
Select a size

Showing 14 / 14 variants — scroll the table for more

Part No (MPN)—3G SKU3G-CBM-05933Model310
Part No (MPN)—3G SKU3G-CBM-05934Model610
Part No (MPN)—3G SKU3G-CBM-05935Model803
Part No (MPN)—3G SKU3G-CBM-05936Model810
Part No (MPN)—3G SKU3G-CBM-05937Model23
Part No (MPN)—3G SKU3G-CBM-05938Model26
Part No (MPN)—3G SKU3G-CBM-05939Model28
Part No (MPN)—3G SKU3G-CBM-05940Model29
Part No (MPN)—3G SKU3G-CBM-05941Model41
Part No (MPN)—3G SKU3G-CBM-05942Model43
Part No (MPN)—3G SKU3G-CBM-05943Model45
Part No (MPN)—3G SKU3G-CBM-05944Model52
Part No (MPN)—3G SKU3G-CBM-05945Model55
Part No (MPN)—3G SKU3G-CBM-05948Model72
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Ask a question

Minta Penawaran

Ajukan pertanyaan

Pertanyaan yang Sering Diajukan

What is the safety time?

The safety time is 10 seconds.

What is the delay between first and second stage?

The delay is approximately 30 seconds.

What is the maximum ambient temperature for the cell?

The maximum ambient temperature for the cell is 70 °C.

Ulasan pelanggan

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first

Pactrol Produk

3G Electric memasok Pactrol burner controls. We supply genuine products and their technical documentation.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas →Transformator Pengapian →Kontrol Pembakar →Suku Cadang →Semua Produk →

Lainnya dari Pactrol

Lihat semua Pactrol suku cadang →
CSS01 12 housing ref 404700
Pactrol
CSS01 12 housing ref 404700
CSS01 24 housing ref 406700
Pactrol
CSS01 24 housing ref 406700
CSS 2 STV01 housing reference 429100/V01
Pactrol
CSS 2 STV01 housing reference 429100/V01
Pactrol
Pactrol
UVV cells Pactrol 110V reference 401600
Molex connector 7 pins
Pactrol
Molex connector 7 pins
CSS 2 RTV01 housing reference 429101/V01
Pactrol
CSS 2 RTV01 housing reference 429101/V01
Housing CSS01 12SJ (SP) V11 reference 404700 V11
Pactrol
Housing CSS01 12SJ (SP) V11 reference 404700 V11
CSS 2 PRTV01 box reference 429103/V01
Pactrol
CSS 2 PRTV01 box reference 429103/V01