SiemensElectronic Air Differential Pressure Sensors

Siemens Differential Pressure Sensor: 0.65 in wc to 0.65 in wc, ±0.40% Accuracy

The Siemens 590-781 is an electronic air differential pressure sensor with a range of 0.65 in wc to 0.65 in wc. It features a 4 to 20mA output, ±0.40% accuracy, a loop resistance of 100 ohms, and requires 0 to 10V DC…

SKU 3G-OTH-68516

Merek
Siemens
Item
Differential Pressure Sensor: 0.65 in wc to 0.65 in wc, ±0.40% Accuracy
Kategori
Electronic Air Differential Pressure Sensors
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyur
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Spesifikasi Teknis

Siemens
Manufacturer Part Number
590-781
Type
±0.40% Accuracy, 4 to 20mA
DC
0 to 10V
Output
4 to 20mA
Accuracy
±0.40%
Power Required
0 to 10V DC
Loop Resistance
100 ohms
Lihat Lembar Spesifikasi Lengkap

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Siemens Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

The Siemens 590-781 is an electronic air differential pressure sensor with a range of 0.65 in wc to 0.65 in wc. It features a 4 to 20mA output, ±0.40% accuracy, a loop resistance of 100 ohms, and requires 0 to 10V DC power.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

What is the Siemens 590-781 differential pressure sensor used for?

The Siemens 590-781 electronic air differential pressure sensor measures low air pressure differences in HVAC systems, clean rooms, and industrial ventilation. It outputs a 4 to 20mA signal with ±0.40% accuracy, enabling precise monitoring and control of air flow or filter status.

What are the specifications of the Siemens 590-781 differential pressure sensor?

The Siemens 590-781 has a range of 0.65 in wc to 0.65 in wc, ±0.40% accuracy, and outputs 4 to 20mA with a loop resistance of 100 ohms. It requires 0 to 10V DC power. This electronic sensor is designed for air differential pressure applications.

Where to buy the Siemens 590-781 differential pressure sensor worldwide?

3G Electric supplies the Siemens 590-781 differential pressure sensor to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this precision air pressure sensor.

How to install the Siemens 590-781 differential pressure sensor?

Mount the Siemens 590-781 in a dry location with the pressure ports oriented downward to prevent moisture ingress. Connect the 4 to 20mA output to a controller with a loop resistance of 100 ohms or less, and supply 0 to 10V DC power. Follow standard HVAC sensor installation practices.

Digunakan dalam

Aplikasi umum untuk Siemens
District cooling plants — LME73 + RWF55 for condenser-water modulation
Inflight catering and food-processing steam boilers — LMG22 with SQN90 air-fuel cross-damper
Hospital steam-plant redundancy — LME41 with QRA2 UV flame detection for dual-fuel boilers
Semiconductor fab process heat — LME23 and SKP55 gas valves on hot-oil heater skids
Container-terminal reefer-deck heating — LMG22 retrofit onto legacy burner racks

Siemens Produk

3G Electric memasok Siemens electronic air differential pressure sensors. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Produk serupa

Dicocokkan berdasarkan spesifikasi dan deskripsi
Siemens
Siemens
SIEMENS Room Pressure Monitor: +/- 0.25" WC (62.5 Pa), BACnet, Terminal Block, 2.17 in Display Size (MPN 547-203A). Key specifications — Manufacturer Part Number: 547-203A; Brand: SIEMENS; Accuracy: ±0.5% of Full Scale; Analog Outputs: SPDT Relay; Display Size: 2.17 in; Measurement Range: +/- 0.25" WC (62.5 Pa); Operating Humidity - Maximum: 95% RH (Non-Condensing); Operating Temperature Range: 32°F to 120°F.
Siemens
Siemens
SIEMENS Room Pressure Monitor: +/- 0.25" WC (62.5 Pa), P1, Terminal Block, 2.17 in Display Size (MPN 547-103A). Key specifications — Manufacturer Part Number: 547-103A; Brand: SIEMENS; Accuracy: ±0.5% of Full Scale; Analog Outputs: SPDT Relay; Display Size: 2.17 in; Measurement Range: +/- 0.25" WC (62.5 Pa); Operating Humidity - Maximum: 95% RH (Non-Condensing); Operating Temperature Range: 32°F to 120°F.
Siemens
Siemens
SIEMENS Room Pressure Monitor: +/- 0.25" WC (62.5 Pa), BACnet, Terminal Block, 2.17 in Display Size (MPN 547-323B). Key specifications — Manufacturer Part Number: 547-323B; Brand: SIEMENS; Accuracy: ±0.25% of Full Scale; Analog Inputs: 0 to 10 V DC; Analog Outputs: 0 to 10V DC (3-Wire); Display Size: 2.17 in; Measurement Range: +/- 0.25" WC (62.5 Pa); Operating Humidity - Maximum: 95% RH (Non-Condensing).
Siemens
Siemens
SIEMENS Room Pressure Monitor: +/- 0.10" WC (25 Pa), P1, Terminal Block, 2.17 in Display Size (MPN 547-312A). Key specifications — Manufacturer Part Number: 547-312A; Brand: SIEMENS; Accuracy: ±0.5% of Full Scale; Analog Inputs: 0 to 5 V DC; Analog Outputs: 4 to 20 mA (2-Wire); Display Size: 2.17 in; Measurement Range: +/- 0.10" WC (25 Pa); Operating Humidity - Maximum: 95% RH (Non-Condensing).
Siemens
Siemens
SIEMENS Room Pressure Monitor: +/- 0.25" WC (62.5 Pa), P1, Terminal Block, 2.17 in Display Size (MPN 547-313B). Key specifications — Manufacturer Part Number: 547-313B; Brand: SIEMENS; Accuracy: ±0.25% of Full Scale; Analog Inputs: 0 to 5 V DC; Analog Outputs: 0 to 5V DC (3-Wire); Display Size: 2.17 in; Measurement Range: +/- 0.25" WC (62.5 Pa); Operating Humidity - Maximum: 95% RH (Non-Condensing).
Siemens
Siemens
SIEMENS Room Pressure Monitor: +/- 0.25" WC (62.5 Pa), P1, Terminal Block, 2.17 in Display Size (MPN 547-103B). Key specifications — Manufacturer Part Number: 547-103B; Brand: SIEMENS; Accuracy: ±0.25% of Full Scale; Analog Outputs: SPDT Relay; Display Size: 2.17 in; Measurement Range: +/- 0.25" WC (62.5 Pa); Operating Humidity - Maximum: 95% RH (Non-Condensing); Operating Temperature Range: 32°F to 120°F.

Lainnya dari Siemens

Lihat semua Siemens suku cadang
Siemens
Siemens
Differential Pressure Sensor: -0.25 in wc to 0.25 in wc, ±1.00% Accuracy, 0 to 10V DC, 0 to 10V DC (MPN 590-510). Key specifications — Accuracy: ±1.00%; Output: 0 to 10V DC; Loop Resistance: 100 ohms; Power Required: 0 to 10V DC; Brand: SIEMENS.
Siemens
Siemens
Differential Pressure Sensor: 0.5 in wc to 0.65 in wc, ±0.40% Accuracy, 0 to 10V DC, 4 to 20mA (MPN 590-782). Key specifications — Accuracy: ±0.40%; Output: 4 to 20mA; Loop Resistance: 100 ohms; Power Required: 0 to 10V DC; Brand: SIEMENS.
Siemens
Siemens
Differential Pressure Sensor: 1 in wc to 1 in wc, ±0.40% Accuracy, 0 to 10V DC, 4 to 20mA, 100 ohms (MPN 590-780). Key specifications — Accuracy: ±0.40%; Output: 4 to 20mA; Loop Resistance: 100 ohms; Power Required: 0 to 10V DC; Brand: SIEMENS.