Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

SIEMENS 3RB31334WB0 IEC Electronic Overload Relay - IEC Electronic Overload Relays
SiemensIEC Electronic Overload Relays

SIEMENS 3RB31334WB0 IEC Electronic Overload Relay

Siemens Overload Relay 3RB31334WB0 adalah relay proteksi elektronik 3 kutub dengan frame size S2 yang dirancang untuk melindungi motor listrik dari beban lebih. Relay ini memiliki konfigurasi kontak bantu 1NO/1NC dan…

SKU 3G-OTH-44975

Merek
Siemens
Item
3RB31334WB0 IEC Electronic Overload Relay
Kategori
IEC Electronic Overload Relays
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Siemens
Manufacturer Part Number
3RB31334WB0
Frame Size
S2
Compatible Contactors
Frame Size S2
Auxiliary Contact Form
1NO/1NC
Maximum Voltage Rating
690V AC
Phase Loss Sensitivity
No
Thermal Units Required
Not Applicable to Electronic Type Overload Relays
Terminal Connection Type
Screw Terminals
Compatible Contactor Series
SIRIUS

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Siemens Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Siemens Overload Relay 3RB31334WB0 adalah relay proteksi elektronik 3 kutub dengan frame size S2 yang dirancang untuk melindungi motor listrik dari beban lebih. Relay ini memiliki konfigurasi kontak bantu 1NO/1NC dan rating tegangan maksimum 690V AC, serta kompatibel dengan kontaktor seri SIRIUS frame size S2. Dengan terminal sambungan tipe sekrup, relay ini ideal untuk aplikasi industri yang membutuhkan perlindungan motor presisi tanpa memerlukan thermal unit.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi Siemens Overload Relay 3RB31334WB0?

Siemens Overload Relay 3RB31334WB0 berfungsi sebagai relay proteksi elektronik untuk melindungi motor listrik 3 fasa dari kondisi beban lebih. Relay ini memiliki frame size S2, kontak bantu 1NO/1NC, dan rating tegangan maksimum 690V AC. Tidak memerlukan thermal unit karena menggunakan teknologi proteksi elektronik.

Apa spesifikasi Siemens Overload Relay 3RB31334WB0?

Spesifikasi Siemens Overload Relay 3RB31334WB0 meliputi: frame size S2, 3 poles, auxiliary contact form 1NO/1NC, maximum voltage rating 690V AC, terminal connection type screw terminals, kompatibel dengan kontaktor seri SIRIUS frame size S2, dan tidak memerlukan thermal units.

Di mana beli Siemens Overload Relay 3RB31334WB0 di Indonesia?

Anda dapat membeli Siemens Overload Relay 3RB31334WB0 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan kepabeanan untuk memastikan produk sampai ke lokasi Anda dengan aman.

Apakah Siemens Overload Relay 3RB31334WB0 kompatibel dengan kontaktor tertentu?

Ya, Siemens Overload Relay 3RB31334WB0 kompatibel dengan kontaktor seri SIRIUS frame size S2. Relay ini memiliki frame size S2 dan terminal sambungan tipe sekrup, sehingga memudahkan pemasangan pada panel kontrol motor industri.

Digunakan dalam

Aplikasi umum untuk Siemens
District cooling plants — LME73 + RWF55 for condenser-water modulation
Inflight catering and food-processing steam boilers — LMG22 with SQN90 air-fuel cross-damper
Hospital steam-plant redundancy — LME41 with QRA2 UV flame detection for dual-fuel boilers
Semiconductor fab process heat — LME23 and SKP55 gas valves on hot-oil heater skids
Container-terminal reefer-deck heating — LMG22 retrofit onto legacy burner racks

Siemens Produk

3G Electric memasok Siemens iec electronic overload relays. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
IEC electronic overload relay for motor protection against overcurrent. Three poles with one normally open and one normally closed auxiliary contact. Rated for 690V AC, with screw terminals. Compatible with SIRIUS contactors of Frame Size S0. No thermal units required
Siemens
IEC electronic overload relay for motor protection against overcurrent. Three poles with one normally open and one normally closed auxiliary contact. Rated for 690V AC, with screw terminals. Compatible with SIRIUS contactors of Frame Size S0. No thermal units required
IEC electronic overload relay for motor protection in industrial automation. Three poles, frame size S00, with 1 normally open and 1 normally closed auxiliary contact. Rated for 690V AC, screw terminal connection. Compatible with SIRIUS contactors of frame size S00; no thermal units required
Siemens
IEC electronic overload relay for motor protection in industrial automation. Three poles, frame size S00, with 1 normally open and 1 normally closed auxiliary contact. Rated for 690V AC, screw terminal connection. Compatible with SIRIUS contactors of frame size S00; no thermal units required
IEC electronic overload relay for motor protection, 3-pole, with 1 normally open and 1 normally closed auxiliary contact. Rated for 1000V AC, with screw terminals. Compatible with SIRIUS contactors of Frame Size S6. No thermal units required; no phase loss sensitivity
Siemens
IEC electronic overload relay for motor protection, 3-pole, with 1 normally open and 1 normally closed auxiliary contact. Rated for 1000V AC, with screw terminals. Compatible with SIRIUS contactors of Frame Size S6. No thermal units required; no phase loss sensitivity
IEC electronic overload relay for motor protection against overload and phase imbalance. Rated 1 A to 4 A, 690 V AC, with 1 normally open and 1 normally closed auxiliary contact. Designed for frame size S00 contactors, with screw terminal connections. Suitable for industrial motor control applications requiring electronic overload protection
Siemens
IEC electronic overload relay for motor protection against overload and phase imbalance. Rated 1 A to 4 A, 690 V AC, with 1 normally open and 1 normally closed auxiliary contact. Designed for frame size S00 contactors, with screw terminal connections. Suitable for industrial motor control applications requiring electronic overload protection
IEC electronic overload relay for motor protection against overload and phase imbalance. Three-pole design with 10 A to 40 A adjustment range, 1NO/1NC auxiliary contacts, and screw terminals. Rated for 690V AC maximum. Compatible with SIRIUS contactors of Frame Size S0. No phase loss sensitivity; no thermal units required
Siemens
IEC electronic overload relay for motor protection against overload and phase imbalance. Three-pole design with 10 A to 40 A adjustment range, 1NO/1NC auxiliary contacts, and screw terminals. Rated for 690V AC maximum. Compatible with SIRIUS contactors of Frame Size S0. No phase loss sensitivity; no thermal units required
IEC electronic overload relay for motor protection in industrial control panels. Three-pole device with screw terminals, rated 690V AC, adjustable current range 3 A to 12 A. Features 1NO/1NC auxiliary contacts and is compatible with SIRIUS contactors of frame size S00. No thermal units required
Siemens
IEC electronic overload relay for motor protection in industrial control panels. Three-pole device with screw terminals, rated 690V AC, adjustable current range 3 A to 12 A. Features 1NO/1NC auxiliary contacts and is compatible with SIRIUS contactors of frame size S00. No thermal units required

Lainnya dari Siemens

Lihat semua Siemens suku cadang
IEC electronic overload relay for motor protection against overcurrent and phase loss. Two-pole design with 1 normally open and 1 normally closed auxiliary contact. Rated for 690V AC, with screw terminals. Compatible with Frame Size A contactors and Class 48 overload relays. Thermal units not required
Siemens
IEC electronic overload relay for motor protection against overcurrent and phase loss. Two-pole design with 1 normally open and 1 normally closed auxiliary contact. Rated for 690V AC, with screw terminals. Compatible with Frame Size A contactors and Class 48 overload relays. Thermal units not required
IEC electronic overload relay for motor protection in industrial control panels. Three-pole device with screw terminals, rated 1 A to 4 A and 690V AC. Features 1 normally open and 1 normally closed auxiliary contact. Compatible with SIRIUS contactors of frame size S0
Siemens
IEC electronic overload relay for motor protection in industrial control panels. Three-pole device with screw terminals, rated 1 A to 4 A and 690V AC. Features 1 normally open and 1 normally closed auxiliary contact. Compatible with SIRIUS contactors of frame size S0
IEC electronic overload relay for motor protection, 3-pole, Frame Size S2, with screw terminals. Current setting range 12 A to 50 A, maximum voltage 690V AC. Auxiliary contact form 1NO/1NC. Compatible with SIRIUS contactors of same frame size. No thermal units required
Siemens
IEC electronic overload relay for motor protection, 3-pole, Frame Size S2, with screw terminals. Current setting range 12 A to 50 A, maximum voltage 690V AC. Auxiliary contact form 1NO/1NC. Compatible with SIRIUS contactors of same frame size. No thermal units required
IEC electronic overload relay for motor protection against overcurrent and phase loss. Three-pole unit with screw terminals, rated 13–52 A and 690V AC. Auxiliary contact form 1NO/1NC. Designed for use with Frame Size B contactors and Class 14 starters in industrial motor control applications
Siemens
IEC electronic overload relay for motor protection against overcurrent and phase loss. Three-pole unit with screw terminals, rated 13–52 A and 690V AC. Auxiliary contact form 1NO/1NC. Designed for use with Frame Size B contactors and Class 14 starters in industrial motor control applications
IEC electronic overload relay for motor protection, 3 poles, adjustable current range 0.32 A to 1.25 A. Frame size S00 with screw terminals, auxiliary contacts 1NO/1NC, rated up to 690 V AC. No thermal units required; compatible with SIRIUS contactors of frame size S00
Siemens
IEC electronic overload relay for motor protection, 3 poles, adjustable current range 0.32 A to 1.25 A. Frame size S00 with screw terminals, auxiliary contacts 1NO/1NC, rated up to 690 V AC. No thermal units required; compatible with SIRIUS contactors of frame size S00
IEC electronic overload relay for motor protection against overcurrent and phase loss. Features 2 poles, 1 normally open and 1 normally closed auxiliary contact, and a maximum voltage rating of 690V AC. Designed for use with Frame Size A1 contactors from the Class 48 series, with screw terminal connections. Thermal units are not required for this electronic type
Siemens
IEC electronic overload relay for motor protection against overcurrent and phase loss. Features 2 poles, 1 normally open and 1 normally closed auxiliary contact, and a maximum voltage rating of 690V AC. Designed for use with Frame Size A1 contactors from the Class 48 series, with screw terminal connections. Thermal units are not required for this electronic type
IEC electronic overload relay with screw terminals, rated 0.25 A to 1 A, 690V AC maximum. Provides motor protection against overcurrent and phase loss. Designed for use with Frame Size A contactors in Class 48 series
Siemens
IEC electronic overload relay with screw terminals, rated 0.25 A to 1 A, 690V AC maximum. Provides motor protection against overcurrent and phase loss. Designed for use with Frame Size A contactors in Class 48 series
IEC electronic overload relay for motor protection against overcurrent conditions. Three-pole unit with frame size S0, current setting range 6 A to 25 A, and auxiliary contact configuration 1NO/1NC. Screw terminal connections, rated for maximum 690V AC. Compatible with SIRIUS contactors of frame size S0. No phase loss sensitivity; no thermal units required
Siemens
IEC electronic overload relay for motor protection against overcurrent conditions. Three-pole unit with frame size S0, current setting range 6 A to 25 A, and auxiliary contact configuration 1NO/1NC. Screw terminal connections, rated for maximum 690V AC. Compatible with SIRIUS contactors of frame size S0. No phase loss sensitivity; no thermal units required