Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

SQUARE D 8910 Series Type DPA Non-Reversing Definite Purpose Contactor - Non-Reversing Definite Purpose Contactors
SQUARE DNon-Reversing Definite Purpose Contactors

SQUARE D 8910 Series Type DPA Non-Reversing Definite Purpose Contactor

SQUARE D Definite Purpose Magnetic Contactor seri 8910 Series Type DPA adalah kontaktor non-reversing 3 kutub yang dirancang khusus untuk aplikasi HVACR. Kontaktor ini memiliki rating arus 40 A, tegangan maksimum…

SKU 3G-OTH-42785

Merek
SQUARE D
Item
8910 Series Type DPA Non-Reversing Definite Purpose Contactor
Kategori
Non-Reversing Definite Purpose Contactors
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

SQUARE D
Manufacturer Part Number
8910DPA43V02Y181
Series
8910 Series Type DPA
Type
40 A, Non-Reversing
AC
120V
Phase
Three
Coil Voltage
110/120V AC
Contactor Style
HVACR Definite Purpose Contactor
Main Pole Contact Form
3NO
Maximum Voltage Rating
600V AC
Terminal Connection Type
Quick-Disconnect Terminals

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

SQUARE D Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

SQUARE D Definite Purpose Magnetic Contactor seri 8910 Series Type DPA adalah kontaktor non-reversing 3 kutub yang dirancang khusus untuk aplikasi HVACR. Kontaktor ini memiliki rating arus 40 A, tegangan maksimum 600V AC, dan koil 110/120V AC. Dengan konfigurasi kontak utama 3NO dan terminal quick-disconnect, produk ini cocok untuk sistem kontrol pembakar industri dan peralatan ketel uap tiga fasa.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi SQUARE D 8910DPA43V02Y181?

SQUARE D 8910DPA43V02Y181 adalah definite purpose magnetic contactor 3 kutub, non-reversing, dengan rating arus 40 A, tegangan maksimum 600V AC, dan koil 110/120V AC. Kontaktor ini memiliki konfigurasi kontak utama 3NO dan terminal quick-disconnect, cocok untuk aplikasi HVACR.

Untuk apa kontaktor SQUARE D 8910DPA43V02Y181 digunakan?

Kontaktor SQUARE D 8910DPA43V02Y181 digunakan untuk mengontrol beban listrik tiga fasa pada sistem HVACR, seperti kompresor, kipas, dan pompa. Produk ini juga umum dipakai pada panel kontrol pembakar industri dan ketel uap.

Di mana beli SQUARE D 8910DPA43V02Y181 di Indonesia?

Anda dapat membeli SQUARE D 8910DPA43V02Y181 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Bagaimana cara memilih kontaktor SQUARE D yang tepat?

Pilih kontaktor SQUARE D berdasarkan rating arus (40 A), tegangan koil (110/120V AC), dan jumlah kutub (3). Pastikan kontaktor non-reversing sesuai untuk aplikasi Anda. Untuk sistem tiga fasa, seri 8910 Type DPA dengan tegangan maksimum 600V AC adalah pilihan yang tepat.

Digunakan dalam

Aplikasi umum untuk SQUARE D
Commercial building electrical panels — Square D QO series plug-in circuit breakers for branch circuit protection
Industrial motor control centers — Square D QOB series bolt-on breakers in NQOD panelboards
Heating equipment installations — Square D QOU series unit-mount breakers for overcurrent protection
Outdoor electrical distribution — Square D L-Frame enclosures housing LAL/LHL breakers for 400 A service
Indoor facility power distribution — Square D Q-Frame enclosures with QBL/QDL breakers for 225 A circuits
Retrofit and replacement in existing Square D load centers — QO series breakers for 120/240V AC systems

SQUARE D Produk

3G Electric memasok SQUARE D non-reversing definite purpose contactors. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Three-pole, three-phase definite purpose contactor with 3NO main pole contact form. Rated 30 A at 480V AC, with 440/480V AC coil voltage and maximum 600V AC. Quick-disconnect terminals. Used for switching HVACR loads such as compressors, condenser fans, and heating equipment
SQUARE D
Three-pole, three-phase definite purpose contactor with 3NO main pole contact form. Rated 30 A at 480V AC, with 440/480V AC coil voltage and maximum 600V AC. Quick-disconnect terminals. Used for switching HVACR loads such as compressors, condenser fans, and heating equipment
Three-phase, 4-pole definite purpose contactor with 4 normally open main poles. Rated 30 A, 600V AC maximum. Coil voltage 110/120V AC. Terminals are quick-disconnect type. Suitable for switching HVACR loads such as compressors, condenser fans, and other three-phase equipment in commercial and industrial systems
SQUARE D
Three-phase, 4-pole definite purpose contactor with 4 normally open main poles. Rated 30 A, 600V AC maximum. Coil voltage 110/120V AC. Terminals are quick-disconnect type. Suitable for switching HVACR loads such as compressors, condenser fans, and other three-phase equipment in commercial and industrial systems
This SQUARE D definite purpose contactor is a 2-pole, non-reversing device with a 2NO main pole contact form. It is rated for 30 A and features a 110/120V AC coil with a maximum voltage rating of 600V AC. The contactor uses quick-disconnect terminals and is designed for single-phase HVACR applications such as controlling compressors and fan motors in air conditioning, refrigeration, and heating systems
SQUARE D
This SQUARE D definite purpose contactor is a 2-pole, non-reversing device with a 2NO main pole contact form. It is rated for 30 A and features a 110/120V AC coil with a maximum voltage rating of 600V AC. The contactor uses quick-disconnect terminals and is designed for single-phase HVACR applications such as controlling compressors and fan motors in air conditioning, refrigeration, and heating systems
Three-phase non-reversing definite purpose contactor rated 90 A at 480V AC. Features 3 normally open main poles, 440/480V AC coil voltage, and quick-disconnect terminals. Suitable for switching HVACR equipment and industrial three-phase loads such as compressors, fans, and pumps
SQUARE D
Three-phase non-reversing definite purpose contactor rated 90 A at 480V AC. Features 3 normally open main poles, 440/480V AC coil voltage, and quick-disconnect terminals. Suitable for switching HVACR equipment and industrial three-phase loads such as compressors, fans, and pumps
Three-pole, three-phase definite purpose contactor rated 50 A with 3NO main pole contact form. Coil voltage 110/120V AC, maximum voltage 600V AC. Box lug terminals. Suitable for switching motor loads in HVACR equipment such as compressors and condenser fans
SQUARE D
Three-pole, three-phase definite purpose contactor rated 50 A with 3NO main pole contact form. Coil voltage 110/120V AC, maximum voltage 600V AC. Box lug terminals. Suitable for switching motor loads in HVACR equipment such as compressors and condenser fans
Three-phase definite purpose contactor with 4 normally open poles, rated 30 A and 277V AC coil. Maximum voltage 600V AC. Screw clamp terminals. Suitable for HVACR equipment such as air conditioning, refrigeration, and heating systems
SQUARE D
Three-phase definite purpose contactor with 4 normally open poles, rated 30 A and 277V AC coil. Maximum voltage 600V AC. Screw clamp terminals. Suitable for HVACR equipment such as air conditioning, refrigeration, and heating systems

Lainnya dari SQUARE D

Lihat semua SQUARE D suku cadang
This SQUARE D 8910 Series Type DPA definite purpose contactor is a non-reversing, single-phase device with 2 normally open main poles. Rated 60 A at 600V AC maximum, it features a 110/120V AC coil and quick-disconnect terminals. Suitable for switching motors, compressors, and other loads in HVACR and industrial equipment
SQUARE D
This SQUARE D 8910 Series Type DPA definite purpose contactor is a non-reversing, single-phase device with 2 normally open main poles. Rated 60 A at 600V AC maximum, it features a 110/120V AC coil and quick-disconnect terminals. Suitable for switching motors, compressors, and other loads in HVACR and industrial equipment
Three-pole, three-phase definite purpose contactor with 3NO main pole contact form. Rated 30 A with 110/120V AC coil and maximum voltage of 600V AC. Screw clamp terminals. Suitable for switching loads such as compressors and fan motors in HVACR systems
SQUARE D
Three-pole, three-phase definite purpose contactor with 3NO main pole contact form. Rated 30 A with 110/120V AC coil and maximum voltage of 600V AC. Screw clamp terminals. Suitable for switching loads such as compressors and fan motors in HVACR systems
This SQUARE D 8910 Series Type DP contactor is a 2-pole, non-reversing definite purpose contactor with a 2NO main pole contact form. It is rated for 30 A and single-phase operation, with a coil voltage of 220/208-240V AC and a maximum voltage rating of 600V AC. Screw clamp terminals provide secure connections. Typical applications include switching loads in HVACR equipment such as air conditioners, heat pumps, and refrigeration units
SQUARE D
This SQUARE D 8910 Series Type DP contactor is a 2-pole, non-reversing definite purpose contactor with a 2NO main pole contact form. It is rated for 30 A and single-phase operation, with a coil voltage of 220/208-240V AC and a maximum voltage rating of 600V AC. Screw clamp terminals provide secure connections. Typical applications include switching loads in HVACR equipment such as air conditioners, heat pumps, and refrigeration units
This SQUARE D definite purpose contactor is a non-reversing, single-phase device with two normally open main poles. It is rated for 30 A at a maximum voltage of 600V AC and features a 24V AC coil. The screw clamp terminals facilitate secure wiring connections. Typical applications include controlling motors in HVACR equipment such as compressors, fans, and pumps
SQUARE D
This SQUARE D definite purpose contactor is a non-reversing, single-phase device with two normally open main poles. It is rated for 30 A at a maximum voltage of 600V AC and features a 24V AC coil. The screw clamp terminals facilitate secure wiring connections. Typical applications include controlling motors in HVACR equipment such as compressors, fans, and pumps
Three-pole, non-reversing definite purpose contactor with 3NO main pole contact form. Rated 30 A, 600V AC maximum, with 24V AC coil and quick-disconnect terminals. Suitable for switching three-phase loads in HVACR equipment such as compressors and fan motors
SQUARE D
Three-pole, non-reversing definite purpose contactor with 3NO main pole contact form. Rated 30 A, 600V AC maximum, with 24V AC coil and quick-disconnect terminals. Suitable for switching three-phase loads in HVACR equipment such as compressors and fan motors
This SQUARE D definite purpose contactor is a non-reversing, 2-pole device with a 110/120V AC coil and 2 normally open main poles. Rated for 50 A at a maximum of 600V AC, it features box lug terminals for secure wiring. Typical applications include switching single-phase loads in HVACR equipment such as air conditioners and refrigeration units
SQUARE D
This SQUARE D definite purpose contactor is a non-reversing, 2-pole device with a 110/120V AC coil and 2 normally open main poles. Rated for 50 A at a maximum of 600V AC, it features box lug terminals for secure wiring. Typical applications include switching single-phase loads in HVACR equipment such as air conditioners and refrigeration units
Non-reversing definite purpose contactor with 4 normally open poles, rated 40 A at 277V AC coil voltage and 600V AC maximum. Three-phase design with quick-disconnect terminals. Suitable for switching loads in HVACR equipment such as compressors, fan motors, and refrigeration units
SQUARE D
Non-reversing definite purpose contactor with 4 normally open poles, rated 40 A at 277V AC coil voltage and 600V AC maximum. Three-phase design with quick-disconnect terminals. Suitable for switching loads in HVACR equipment such as compressors, fan motors, and refrigeration units
Three-pole, non-reversing definite purpose contactor with 3NO main pole contact form. Rated 50 A with 220/208-240V AC coil voltage and maximum voltage rating of 600V AC. Terminals are box lug type. Suitable for switching three-phase loads in HVACR equipment such as compressors, fan motors, and refrigeration units
SQUARE D
Three-pole, non-reversing definite purpose contactor with 3NO main pole contact form. Rated 50 A with 220/208-240V AC coil voltage and maximum voltage rating of 600V AC. Terminals are box lug type. Suitable for switching three-phase loads in HVACR equipment such as compressors, fan motors, and refrigeration units