TACO Low Water Cutoff LFA1203S-1 adalah kontrol pengaman ketel uap dan air panas yang dirancang untuk mematikan pembakar secara otomatis saat level air turun di bawah batas aman. Dengan spesifikasi AC 120V, tipe SPDT…

SKU 3G-OTH-68343

Juga terdaftar sebagai: LFA1203S1 · LFA1203S 1

Merek
TACO
Item
LFA1203S-1 Low-Water Cut-Off Control
Kategori
Low-Water Cut-Off Controls
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

TACO
Manufacturer Part Number
LFA1203S-1
Type
SPDT, Auto Reset, Foam Compensating
AC
120V
Reset Type
Automatic
NEMA Rating
1
Switch Type
SPDT
Compensates for Foam
Yes
Test Button Included
Yes

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

TACO Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

TACO Low Water Cutoff LFA1203S-1 adalah kontrol pengaman ketel uap dan air panas yang dirancang untuk mematikan pembakar secara otomatis saat level air turun di bawah batas aman. Dengan spesifikasi AC 120V, tipe SPDT dengan reset otomatis, dan fitur kompensasi busa (foam compensating), produk ini memastikan perlindungan optimal pada sistem ketel uap Anda. Dilengkapi tombol uji (test button) dan rating NEMA 1, kontrol ini cocok untuk aplikasi pembakar industri dan peralatan pembakaran di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi TACO Low Water Cutoff LFA1203S-1?

TACO Low Water Cutoff LFA1203S-1 berfungsi sebagai pengaman otomatis pada ketel uap dan air panas. Saat level air turun, kontrol ini akan mematikan pembakar untuk mencegah kerusakan akibat kekurangan air. Produk ini memiliki tipe SPDT dengan reset otomatis dan fitur kompensasi busa, serta dilengkapi tombol uji untuk verasi fungsi.

Apa spesifikasi TACO LFA1203S-1?

Spesifikasi TACO LFA1203S-1 meliputi tegangan AC 120V, tipe SPDT dengan reset otomatis, kompensasi busa (foam compensating), tombol uji (test button) terintegrasi, dan rating NEMA 1. Produk ini dirancang khusus untuk aplikasi ketel uap dan air panas, memastikan keandalan dalam sistem pembakaran industri.

Di mana beli TACO Low Water Cutoff LFA1203S-1 di Indonesia?

Anda dapat membeli TACO Low Water Cutoff LFA1203S-1 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai, sehingga Anda dapat menerima suku cadang pembakar ini dengan mudah. Hubungi kami untuk minta penawaran.

Bagaimana cara memilih low water cutoff yang tepat untuk ketel uap?

Pilih low water cutoff yang sesuai dengan tegangan sistem Anda, seperti TACO LFA1203S-1 yang bertegangan AC 120V. Pastikan tipe switch SPDT dengan reset otomatis dan fitur kompensasi busa jika diperlukan. Produk ini juga dilengkapi tombol uji untuk memudahkan pengecekan rutin pada peralatan pembakaran Anda.

Digunakan dalam

Aplikasi umum untuk TACO
Hydronic heating systems — TACO 007 series circulator pumps for residential boiler water circulation.
Commercial HVAC — TACO 2400-60-3P inline pump for chilled water loops in large buildings.
Industrial process cooling — TACO 1630EAE10132096 pump for high-flow (110 gpm) cooling applications.
Zone control in radiant floor heating — TACO V075T2G2ZA024Q4A2 zone valve for regulating flow to individual zones.
Pump replacement and maintenance — TACO 007-045RP cartridge assembly for servicing existing 007 series pumps.
Piping connections in hydronic systems — TACO 110-251F-1 flange for joining pumps to pipework.

TACO Produk

3G Electric memasok TACO low-water cut-off controls. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
This 1-inch CPVC electrically-actuated ball valve provides automated on/off flow control. The actuator includes thermal overload protection and operates on 24 to 265V AC/DC power. Suitable for corrosive fluid handling in industrial piping systems
HAYWARD FLOW CONTROL
This 1-inch CPVC electrically-actuated ball valve provides automated on/off flow control. The actuator includes thermal overload protection and operates on 24 to 265V AC/DC power. Suitable for corrosive fluid handling in industrial piping systems
HAYWARD FLOW CONTROL Electrically Actuated Two-Way Ball Valve: 2 in, PVC, 24 to 265V AC/DC, Straight (MPN ECPTBH120STV)
HAYWARD FLOW CONTROL
HAYWARD FLOW CONTROL Electrically Actuated Two-Way Ball Valve: 2 in, PVC, 24 to 265V AC/DC, Straight (MPN ECPTBH120STV)
This CPVC electrically-actuated two-way ball valve is suited for automated on/off flow control in corrosive fluid handling systems. It operates on 24 to 265V AC/DC power and includes a manual override for backup operation. The 2-inch valve body is constructed from CPVC for chemical resistance
HAYWARD FLOW CONTROL
This CPVC electrically-actuated two-way ball valve is suited for automated on/off flow control in corrosive fluid handling systems. It operates on 24 to 265V AC/DC power and includes a manual override for backup operation. The 2-inch valve body is constructed from CPVC for chemical resistance
This CPVC electrically-actuated ball valve is designed for automated on/off flow control in corrosive fluid handling systems. The valve body is constructed from CPVC, and the actuator includes a heater for reliable operation across a wide voltage range of 24 to 265V AC/DC. Suitable for applications such as chemical processing and water treatment where corrosion resistance and remote actuation are required
HAYWARD FLOW CONTROL
This CPVC electrically-actuated ball valve is designed for automated on/off flow control in corrosive fluid handling systems. The valve body is constructed from CPVC, and the actuator includes a heater for reliable operation across a wide voltage range of 24 to 265V AC/DC. Suitable for applications such as chemical processing and water treatment where corrosion resistance and remote actuation are required
This CPVC electrically-actuated ball valve is designed for automated on/off flow control in industrial piping systems. It features a 1 1/2 in two-way valve body and an actuator with thermal overload protection, operating on 24 to 265V AC/DC power. Suitable for applications requiring corrosion resistance
HAYWARD FLOW CONTROL
This CPVC electrically-actuated ball valve is designed for automated on/off flow control in industrial piping systems. It features a 1 1/2 in two-way valve body and an actuator with thermal overload protection, operating on 24 to 265V AC/DC power. Suitable for applications requiring corrosion resistance
This CPVC electrically-actuated two-way ball valve is used for automated on/off flow control in industrial piping systems. It operates on 24 to 265V AC/DC power and includes status indicator lights on the actuator. Suitable for corrosive fluid handling applications such as chemical processing, water treatment, and plating
HAYWARD FLOW CONTROL
This CPVC electrically-actuated two-way ball valve is used for automated on/off flow control in industrial piping systems. It operates on 24 to 265V AC/DC power and includes status indicator lights on the actuator. Suitable for corrosive fluid handling applications such as chemical processing, water treatment, and plating

Lainnya dari TACO

Lihat semua TACO suku cadang
Low-water cut-off control for steam and hot water boilers. Features a manual reset SPDT switch, NEMA 1 enclosure, and a test button. Compensates for foam to prevent false trips. Operates on 120V AC
TACO
Low-water cut-off control for steam and hot water boilers. Features a manual reset SPDT switch, NEMA 1 enclosure, and a test button. Compensates for foam to prevent false trips. Operates on 120V AC
Low-water cut-off control for steam and hot water boilers. Operates on 24V AC with SPDT switch type and automatic reset. Includes foam compensation to prevent false trips and a test button. NEMA 1 rated enclosure
TACO
Low-water cut-off control for steam and hot water boilers. Operates on 24V AC with SPDT switch type and automatic reset. Includes foam compensation to prevent false trips and a test button. NEMA 1 rated enclosure
Low-water cut-off control for steam and hot water boilers. Features manual reset SPDT switch, foam compensating function, and integrated test button. Operates on 24V AC with NEMA 1 enclosure. Automatically shuts down burner to prevent damage from low water conditions
TACO
Low-water cut-off control for steam and hot water boilers. Features manual reset SPDT switch, foam compensating function, and integrated test button. Operates on 24V AC with NEMA 1 enclosure. Automatically shuts down burner to prevent damage from low water conditions
Low-water cut-off control for residential boilers, automatically shuts off burner when water level drops to prevent dry-fire damage. Features SPDT switch, automatic reset, NEMA 1 enclosure, and test button. Operates on 24V AC and does not compensate for foam
TACO
Low-water cut-off control for residential boilers, automatically shuts off burner when water level drops to prevent dry-fire damage. Features SPDT switch, automatic reset, NEMA 1 enclosure, and test button. Operates on 24V AC and does not compensate for foam
This low-water cut-off control protects hot water boilers by shutting down the burner when water level drops. It features SPDT switch, automatic reset, and a test button. Operates on 24V AC with NEMA 1 rating. Does not compensate for foam
TACO
This low-water cut-off control protects hot water boilers by shutting down the burner when water level drops. It features SPDT switch, automatic reset, and a test button. Operates on 24V AC with NEMA 1 rating. Does not compensate for foam