The TJERNLUND HSJ is a pipe-mount exhaust draft inducer designed for natural-gas water heaters. It operates on 115V AC, draws 1.26 A, and includes a fan proving switch. This unit is cETL Listed.

SKU 3G-OTH-75239

Merek
TJERNLUND
Item
Induced Draft Blower: For Boilers/Water Heaters, For 4 in Pipe, 110 cfm @ 0.0 in SP
Kategori
Pipe-Mount Exhaust Draft Inducers
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyur
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Spesifikasi Teknis

TJERNLUND
Manufacturer Part Number
HSJ
Type
For 4 in Pipe, 110 cfm @ 0.0 in SP
AC
115V
Current
1.26 A
Includes
Fan Proving Switch
Standards
cETL Listed
Application
Water Heaters
For Fuel Type
Natural Gas
Nominal Voltage
115V AC
Nameplate Voltage
115V AC
Lihat Lembar Spesifikasi Lengkap

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

TJERNLUND Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

The TJERNLUND HSJ is a pipe-mount exhaust draft inducer designed for natural-gas water heaters. It operates on 115V AC, draws 1.26 A, and includes a fan proving switch. This unit is cETL Listed.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

What is the TJERNLUND HSJ induced draft blower used for?

The TJERNLUND HSJ is a pipe-mount exhaust draft inducer used to improve venting in natural-gas water heaters. It mounts directly on 4-inch pipe and includes a fan proving switch for safety. This cETL Listed unit operates on 115V AC and draws 1.26 A.

What are the specifications of the TJERNLUND HSJ?

The TJERNLUND HSJ is a 115V AC induced draft blower rated at 1.26 A, delivering 110 cfm at 0.0 in SP. It is designed for 4-inch pipe, natural gas, and includes a fan proving switch. The unit is cETL Listed and manufactured by TJERNLUND.

Where to buy the TJERNLUND HSJ induced draft blower worldwide?

3G Electric supplies the TJERNLUND HSJ induced draft blower to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery. Contact us to order this cETL Listed, 115V AC draft inducer for your natural-gas water heater application.

How to install the TJERNLUND HSJ draft inducer?

Install the TJERNLUND HSJ by mounting it directly on a 4-inch vent pipe from the water heater. Ensure the fan proving switch is wired per local codes and the 115V AC supply is properly grounded. Always follow the manufacturer's instructions and consult a qualified technician for gas appliance venting.

Digunakan dalam

Aplikasi umum untuk TJERNLUND
Residential furnace venting — TJERNLUND GPAK1 pipe-mount draft inducer for natural gas furnaces with 4 in pipe
Oil heating exhaust — TJERNLUND RT750 roof-mount draft inducer for furnaces and oil heating, 8 in to 10 in pipe
LP water heater venting — TJERNLUND HS2 pipe-mount draft inducer with UC1 control for water heaters using LP fuel
Radon mitigation — TJERNLUND PVC4 inline duct fan for 4 in PVC ductwork, 80 cfm max, 115V AC
Vent termination — TJERNLUND VH1-6 wall cap vent hood for 6 in aluminum duct, with screen
Draft monitoring — TJERNLUND PS2501 adjustable air pressure switch for HVAC systems, 0.05 to 12 in wc range

TJERNLUND Produk

3G Electric memasok TJERNLUND pipe-mount exhaust draft inducers. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Lainnya dari TJERNLUND

Lihat semua TJERNLUND suku cadang
Induced Draft Blower: For Boilers/Water Heaters, For 10 in to 14 in Pipe, 115V AC (MPN HS5). Key specifications — Manufacturer Part Number: HS5; Brand: TJERNLUND; Current: 12.6 A; Application: Boilers; Includes: Fan Proving Switch; For Fuel Type: LP; Nameplate Voltage: 115V AC; Nominal Voltage: 115V AC.
TJERNLUND
Induced Draft Blower: For Boilers/Water Heaters, For 10 in to 14 in Pipe, 115V AC (MPN HS5). Key specifications — Manufacturer Part Number: HS5; Brand: TJERNLUND; Current: 12.6 A; Application: Boilers; Includes: Fan Proving Switch; For Fuel Type: LP; Nameplate Voltage: 115V AC; Nominal Voltage: 115V AC.
Power Venter: For Oil Heating, For 4 in Pipe, 180,000 BtuH Max Heater BTU Input for Gas Appliance (MPN SS2). Key specifications — Manufacturer Part Number: SS2; Brand: TJERNLUND; Current: 2.3 A; Application: Oil Heating; Includes: Power Vent System; Standards: ETL Listed; For Fuel Type: Natural Gas; Nameplate Voltage: 115V AC.
TJERNLUND
Power Venter: For Oil Heating, For 4 in Pipe, 180,000 BtuH Max Heater BTU Input for Gas Appliance (MPN SS2). Key specifications — Manufacturer Part Number: SS2; Brand: TJERNLUND; Current: 2.3 A; Application: Oil Heating; Includes: Power Vent System; Standards: ETL Listed; For Fuel Type: Natural Gas; Nameplate Voltage: 115V AC.
Draft Inducer: For Boilers/Furnaces/Water Heaters, For 5 in to 8 in Pipe, 115V AC (MPN D-3). Key specifications — Manufacturer Part Number: D-3; Brand: TJERNLUND; Current: 0.96 A; Application: Furnaces; For Fuel Type: Oil; Frequency: 60 Hz; Nameplate Voltage: 115V AC; Nominal Voltage: 115V AC.
TJERNLUND
Draft Inducer: For Boilers/Furnaces/Water Heaters, For 5 in to 8 in Pipe, 115V AC (MPN D-3). Key specifications — Manufacturer Part Number: D-3; Brand: TJERNLUND; Current: 0.96 A; Application: Furnaces; For Fuel Type: Oil; Frequency: 60 Hz; Nameplate Voltage: 115V AC; Nominal Voltage: 115V AC.
Power Venter: For Oil Heating, For 6 in Pipe, 160,000 BtuH Max Heater BTU Input for Gas Appliance (MPN SS1). Key specifications — Manufacturer Part Number: SS1; Brand: TJERNLUND; Current: 2.8 A; Application: Oil Heating; Includes: Power Vent System; Standards: ETL Listed; For Fuel Type: LP; Nameplate Voltage: 115V AC.
TJERNLUND
Power Venter: For Oil Heating, For 6 in Pipe, 160,000 BtuH Max Heater BTU Input for Gas Appliance (MPN SS1). Key specifications — Manufacturer Part Number: SS1; Brand: TJERNLUND; Current: 2.8 A; Application: Oil Heating; Includes: Power Vent System; Standards: ETL Listed; For Fuel Type: LP; Nameplate Voltage: 115V AC.
Induced Draft Blower: For Boilers/Water Heaters, For 8 in to 12 in Pipe, 115V AC (MPN HS4). Key specifications — Manufacturer Part Number: HS4; Brand: TJERNLUND; Current: 5.8 A; Application: Boilers; Includes: Fan Proving Switch; For Fuel Type: LP; Nameplate Voltage: 115V AC; Nominal Voltage: 115V AC.
TJERNLUND
Induced Draft Blower: For Boilers/Water Heaters, For 8 in to 12 in Pipe, 115V AC (MPN HS4). Key specifications — Manufacturer Part Number: HS4; Brand: TJERNLUND; Current: 5.8 A; Application: Boilers; Includes: Fan Proving Switch; For Fuel Type: LP; Nameplate Voltage: 115V AC; Nominal Voltage: 115V AC.
Induced Draft Blower: For Boilers/Water Heaters, For 8 in to 10 in Pipe, 115V AC (MPN HS3). Key specifications — Manufacturer Part Number: HS3; Brand: TJERNLUND; Current: 2.57 A; Application: Water Heaters; Includes: Fan Proving Switch; Standards: ETL Listed; For Fuel Type: Natural Gas; Nameplate Voltage: 115V AC.
TJERNLUND
Induced Draft Blower: For Boilers/Water Heaters, For 8 in to 10 in Pipe, 115V AC (MPN HS3). Key specifications — Manufacturer Part Number: HS3; Brand: TJERNLUND; Current: 2.57 A; Application: Water Heaters; Includes: Fan Proving Switch; Standards: ETL Listed; For Fuel Type: Natural Gas; Nameplate Voltage: 115V AC.
Draft Inducer: For Boilers/Furnaces/Water Heaters, For 3 in to 6 in Pipe, 115V AC (MPN DJ-3). Key specifications — Manufacturer Part Number: DJ-3; Brand: TJERNLUND; Current: 0.43 A; Application: Boilers; For Fuel Type: Coal; Frequency: 60 Hz; Nameplate Voltage: 115V AC; Nominal Voltage: 115V AC.
TJERNLUND
Draft Inducer: For Boilers/Furnaces/Water Heaters, For 3 in to 6 in Pipe, 115V AC (MPN DJ-3). Key specifications — Manufacturer Part Number: DJ-3; Brand: TJERNLUND; Current: 0.43 A; Application: Boilers; For Fuel Type: Coal; Frequency: 60 Hz; Nameplate Voltage: 115V AC; Nominal Voltage: 115V AC.
Draft Inducer: For Boilers/Furnaces/Water Heaters, For 8 in to 12 in Pipe, 115V AC, Fastening Band. Key specifications — Manufacturer Part Number: I; Brand: TJERNLUND; Current: 5.4 A; Application: Boilers; Includes: Fastening Band; For Fuel Type: Oil; Frequency: 60 Hz; Nameplate Voltage: 115V AC.
TJERNLUND
Draft Inducer: For Boilers/Furnaces/Water Heaters, For 8 in to 12 in Pipe, 115V AC, Fastening Band. Key specifications — Manufacturer Part Number: I; Brand: TJERNLUND; Current: 5.4 A; Application: Boilers; Includes: Fastening Band; For Fuel Type: Oil; Frequency: 60 Hz; Nameplate Voltage: 115V AC.