Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

VICTOR Flowmeter Regulator - Flowmeter Regulators
VICTORFlowmeter Regulators

VICTOR Flowmeter Regulator

VICTOR Flowmeter dengan inlet 1/2 in NPT F dan outlet 1/4 in NPT M adalah flowmeter regulator yang dirancang khusus untuk gas Carbon Dioxide (CO₂) dengan kapasitas 100 scfh. Produk ini ideal untuk aplikasi pengelasan…

SKU 3G-OTH-358187

Juga terdaftar sebagai: 07992198 · 0799 2198

Merek
VICTOR
Item
Flowmeter Regulator
Kategori
Flowmeter Regulators
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

VICTOR
Manufacturer Part Number
0799-2198
Type
1/4 in NPT M Outlet, 100 scfh (Carbon Dioxide)
Inlet Connection
1/2 in NPT F
Outlet Connection
1/4 in NPT M
Compatible Gas Type
Carbon Dioxide

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

VICTOR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

VICTOR Flowmeter dengan inlet 1/2 in NPT F dan outlet 1/4 in NPT M adalah flowmeter regulator yang dirancang khusus untuk gas Carbon Dioxide (CO₂) dengan kapasitas 100 scfh. Produk ini ideal untuk aplikasi pengelasan dan pemotongan industri yang memerlukan pengaturan aliran CO₂ secara presisi. Sebagai bagian dari rangkaian peralatan pembakaran, flowmeter ini memastikan pasokan gas yang stabil dan akurat untuk proses produksi Anda.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa VICTOR Flowmeter 1/2 in NPT F digunakan?

VICTOR Flowmeter dengan inlet 1/2 in NPT F dan outlet 1/4 in NPT M digunakan untuk mengukur dan mengatur aliran gas Carbon Dioxide (CO₂) hingga 100 scfh. Produk ini cocok untuk aplikasi pengelasan, pemotongan, atau proses industri yang memerlukan kontrol aliran CO₂ yang presisi.

Apa spesifikasi VICTOR Flowmeter 0799-2198?

Spesifikasi VICTOR Flowmeter model 0799-2198 meliputi: inlet 1/2 in NPT F, outlet 1/4 in NPT M, kompatibel dengan gas Carbon Dioxide, dan kapasitas aliran 100 scfh. Produk ini dirancang untuk memberikan pengukuran aliran yang akurat dalam sistem gas CO₂.

Di mana beli VICTOR Flowmeter 1/2 in NPT F di Indonesia?

Anda dapat membeli VICTOR Flowmeter 1/2 in NPT F di Indonesia melalui 3G Electric, distributor resmi yang menyediakan produk ini. Kami menangani logistik dan bea cukai untuk pengiriman ke seluruh Indonesia, sehingga Anda dapat menerima produk dengan mudah dan cepat.

Bagaimana cara memilih flowmeter regulator yang tepat untuk CO₂?

Untuk memilih flowmeter regulator yang tepat untuk CO₂, pastikan produk kompatibel dengan gas Carbon Dioxide, seperti VICTOR Flowmeter 0799-2198. Periksa ukuran inlet (1/2 in NPT F) dan outlet (1/4 in NPT M) serta kapasitas aliran (100 scfh) sesuai kebutuhan aplikasi Anda.

Digunakan dalam

Aplikasi umum untuk VICTOR
Metal fabrication shops — VICTOR 1-GPP Series cutting tips for propylene-fueled handheld torch cutting of steel plate.
Pipeline maintenance — VICTOR single-stage fuel gas regulator (MPN 0781-0589) for controlling propane supply to heating nozzles.
Industrial heating applications — VICTOR MFN Series heating nozzle (MPN 0323-0304) for preheating metal before welding or bending.
Gas distribution systems — VICTOR flashback arrestor set (MPN 0656-0001) installed on torch handles to prevent flashback in oxygen-fuel setups.
Carbon dioxide shielding gas systems — VICTOR single-stage regulator (MPN 0781-3615) for regulating CO2 flow in welding operations.
Scrap metal cutting — VICTOR 55 Series heating nozzle (MPN 0323-0326) used with propane for heavy-duty heating and cutting applications.

VICTOR Produk

3G Electric memasok VICTOR flowmeter regulators. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
VICTOR
VICTOR
This VICTOR flowmeter is designed for carbon dioxide gas service, with a 1/4 in NPT male inlet and a 5/8"-18 female right-hand outlet. It provides a maximum flow capacity of 100 scfh for CO2. Typical applications include measuring and regulating CO2 flow in welding, cutting, and beverage carbonation systems
This flow gauge regulator from VICTOR features a CGA 580 inlet and a 5/8"-18 female right-hand outlet. It delivers up to 50 scfh for both Argon and Carbon Dioxide, suitable for controlling and measuring gas flow in welding and industrial gas applications
VICTOR
This flow gauge regulator from VICTOR features a CGA 580 inlet and a 5/8"-18 female right-hand outlet. It delivers up to 50 scfh for both Argon and Carbon Dioxide, suitable for controlling and measuring gas flow in welding and industrial gas applications
This flow gauge regulator from VICTOR is designed for use with Carbon Dioxide gas. It features a CGA 580 inlet connection and a 5/8"-18 female right-hand outlet, with flow capacities of 50 scfh for Argon and 38 scfh for Carbon Dioxide. Commonly used in welding and industrial gas applications to control and measure gas flow from a cylinder
VICTOR
This flow gauge regulator from VICTOR is designed for use with Carbon Dioxide gas. It features a CGA 580 inlet connection and a 5/8"-18 female right-hand outlet, with flow capacities of 50 scfh for Argon and 38 scfh for Carbon Dioxide. Commonly used in welding and industrial gas applications to control and measure gas flow from a cylinder
VICTOR
VICTOR
Flow gauge regulator for Carbon Dioxide with CGA 320 inlet and 5/8"-18 female right-hand outlet. Provides 50 scfh flow capacity for both Carbon Dioxide and Argon. Used to control and measure gas flow from cylinders in welding and industrial gas systems
This VICTOR flowmeter is designed for measuring and regulating the flow of carbon dioxide gas. It features a 1/4 in NPT M inlet connection and a 5/8"-18 F RH outlet connection. Commonly used in welding, beverage dispensing, and laboratory gas systems to provide accurate flow control for CO2 processes
VICTOR
This VICTOR flowmeter is designed for measuring and regulating the flow of carbon dioxide gas. It features a 1/4 in NPT M inlet connection and a 5/8"-18 F RH outlet connection. Commonly used in welding, beverage dispensing, and laboratory gas systems to provide accurate flow control for CO2 processes
This flow gauge regulator from VICTOR features a CGA 580 inlet and a 5/8"-18 F RH outlet. It is rated for 80 scfh with argon and 80 scfh with carbon dioxide. Used in welding and industrial gas systems to control and measure gas flow
VICTOR
This flow gauge regulator from VICTOR features a CGA 580 inlet and a 5/8"-18 F RH outlet. It is rated for 80 scfh with argon and 80 scfh with carbon dioxide. Used in welding and industrial gas systems to control and measure gas flow

Lainnya dari VICTOR

Lihat semua VICTOR suku cadang
This flowmeter regulator from VICTOR is designed for carbon dioxide gas service. It features a 1/2 in NPT female inlet and a 1/4 in NPT male outlet, with a flow capacity of 100 scfh. Commonly used in welding, beverage dispensing, and laboratory applications where precise flow control and measurement of CO2 is required
VICTOR
This flowmeter regulator from VICTOR is designed for carbon dioxide gas service. It features a 1/2 in NPT female inlet and a 1/4 in NPT male outlet, with a flow capacity of 100 scfh. Commonly used in welding, beverage dispensing, and laboratory applications where precise flow control and measurement of CO2 is required
Flowmeter regulator for carbon dioxide with CGA 320 inlet and 5/8"-18 female right-hand outlet. Used to control and measure CO2 flow from a cylinder in welding, beverage dispensing, and industrial gas applications
VICTOR
Flowmeter regulator for carbon dioxide with CGA 320 inlet and 5/8"-18 female right-hand outlet. Used to control and measure CO2 flow from a cylinder in welding, beverage dispensing, and industrial gas applications
This VICTOR flowmeter regulator combines pressure regulation and flow measurement for carbon dioxide gas. It features a CGA 580 inlet connection and a 5/8"-18 female right-hand outlet. Suitable for use in welding and other industrial gas applications where precise CO2 flow control is required
VICTOR
This VICTOR flowmeter regulator combines pressure regulation and flow measurement for carbon dioxide gas. It features a CGA 580 inlet connection and a 5/8"-18 female right-hand outlet. Suitable for use in welding and other industrial gas applications where precise CO2 flow control is required
This VICTOR flowmeter regulator is designed for use with Nitrogen gas. It features a CGA 580 inlet connection and a 5/8"-18 female right-hand outlet, with a flow capacity of 60 scfh. Commonly used in welding, heat treating, and laboratory gas supply applications to precisely control and measure gas flow
VICTOR
This VICTOR flowmeter regulator is designed for use with Nitrogen gas. It features a CGA 580 inlet connection and a 5/8"-18 female right-hand outlet, with a flow capacity of 60 scfh. Commonly used in welding, heat treating, and laboratory gas supply applications to precisely control and measure gas flow
This VICTOR flowmeter regulator is designed for use with argon gas. It features a CGA 580 inlet connection and a 5/8"-18 female right-hand outlet. The unit combines pressure regulation with a flowmeter to provide controlled gas delivery for welding and industrial processes
VICTOR
This VICTOR flowmeter regulator is designed for use with argon gas. It features a CGA 580 inlet connection and a 5/8"-18 female right-hand outlet. The unit combines pressure regulation with a flowmeter to provide controlled gas delivery for welding and industrial processes
This VICTOR flowmeter regulator is designed for use with carbon dioxide gas. It features a 1/2 in NPT female inlet and a 1/4 in NPT male outlet, with a flow capacity of 100 scfh. Typical applications include controlling and measuring CO2 flow in welding, beverage dispensing, or laboratory processes
VICTOR
This VICTOR flowmeter regulator is designed for use with carbon dioxide gas. It features a 1/2 in NPT female inlet and a 1/4 in NPT male outlet, with a flow capacity of 100 scfh. Typical applications include controlling and measuring CO2 flow in welding, beverage dispensing, or laboratory processes