Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Watts Dual Check with Atmospheric Vent: 9BD, 3/8 in Pipe Size, Flare x Flare - Carbonated Water Line Dual Check Backflow Preventers
WattsCarbonated Water Line Dual Check Backflow Preventers

Watts Dual Check with Atmospheric Vent: 9BD, 3/8 in Pipe Size, Flare x Flare

WATTS Dual Check with Atmospheric Vent model 9BD adalah alat pencegah aliran balik (backflow preventer) khusus untuk saluran air berkarbonasi. Produk ini memiliki koneksi Flare x Flare dengan ukuran pipa 3/8 inci dan…

SKU 3G-OTH-428546

Merek
Watts
Item
Dual Check with Atmospheric Vent: 9BD, 3/8 in Pipe Size, Flare x Flare
Kategori
Carbonated Water Line Dual Check Backflow Preventers
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Watts
Manufacturer Part Number
9BD
Type
Flare x Flare, 9BD
Pipe Size
3/8 in
Flow Rate
2.5 gpm
Connection Type
Flare x Flare

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Watts Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

WATTS Dual Check with Atmospheric Vent model 9BD adalah alat pencegah aliran balik (backflow preventer) khusus untuk saluran air berkarbonasi. Produk ini memiliki koneksi Flare x Flare dengan ukuran pipa 3/8 inci dan mampu menangani laju aliran hingga 2.5 gpm. Dirancang untuk melindungi sistem perpipaan dari kontaminasi akibat tekanan balik, unit ini merupakan solusi andal untuk aplikasi minuman dan industri makanan-minuman di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi WATTS Dual Check with Atmospheric Vent 9BD?

WATTS Dual Check with Atmospheric Vent 9BD berfungsi sebagai pencegah aliran balik pada saluran air berkarbonasi. Dengan koneksi Flare x Flare dan ukuran pipa 3/8 inci, alat ini memastikan air berkarbonasi tidak mengalir kembali ke sistem perpipaan utama, menjaga kebersihan dan keamanan pasokan air.

Apa spesifikasi teknis WATTS 9BD?

Spesifikasi WATTS 9BD meliputi tipe Flare x Flare, ukuran pipa 3/8 inci, laju aliran maksimum 2.5 gpm, dan nomor komponen 9BD. Produk ini dirancang khusus untuk saluran air berkarbonasi dan menggunakan mekanisme dual check dengan ventilasi atmosfer.

Di mana beli WATTS 9BD di Indonesia?

Anda dapat membeli WATTS 9BD melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai sehingga Anda menerima produk dengan aman dan tepat waktu. Hubungi kami untuk minta penawaran.

Bagaimana cara memilih WATTS 9BD yang tepat?

Pastikan Anda memilih WATTS 9BD dengan koneksi Flare x Flare dan ukuran pipa 3/8 inci sesuai kebutuhan saluran air berkarbonasi Anda. Periksa laju aliran maksimum 2.5 gpm agar sesuai dengan kapasitas sistem. Jika ragu, konsultasikan dengan teknisi atau hubungi 3G Electric untuk bantuan.

Digunakan dalam

Aplikasi umum untuk Watts
Industrial burner gas safety systems — Watts HF2000 filters with GF-series seal kits maintain clean, regulated gas supply to burner pilot and main flame controls
Commercial heating and boiler installations — Modular filter assemblies support preventive maintenance and component replacement without full system shutdown
Process gas delivery pipelines — DN25 through DN125 filter bodies accommodate varying flow rates and inlet pressures across manufacturing and chemical processes
Gas pressure regulation benches — Multi-stage Watts filter platforms integrate with pressure reducers and safety shutoff valves in test and calibration environments
Equipment retrofit and upgrade projects — Available connection sizes and seal kits enable adaptation of newer Watts components into legacy gas control systems
Planned maintenance and spare-parts inventory — Filter seal kits allow facilities to stock consumables in advance, reducing downtime during scheduled gas system servicing

Watts Produk

3G Electric memasok Watts carbonated water line dual check backflow preventers. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
WATTS Dual Check w Atmospheric Vent: 912HP, 3/4 in Pipe Size, FNPT x MNPT, 22 gpm Flow Rate, Brass (MPN 912-HP 3/4")
Watts
WATTS Dual Check w Atmospheric Vent: 912HP, 3/4 in Pipe Size, FNPT x MNPT, 22 gpm Flow Rate, Brass (MPN 912-HP 3/4")
WATTS Dual Check Vacuum Breaker: LFN9-CD, 3/4 in Pipe Size, FGHT x MGHT, 5 gpm Flow Rate, Brass, GHT (MPN LFN9CD)
Watts
WATTS Dual Check Vacuum Breaker: LFN9-CD, 3/4 in Pipe Size, FGHT x MGHT, 5 gpm Flow Rate, Brass, GHT (MPN LFN9CD)
WATTS Dual Check w Atmospheric Vent: 9D, 1/2 in Pipe Size, FNPT x FNPT, 18.7 gpm Flow Rate, Brass (MPN 9D-M3-1/2")
Watts
WATTS Dual Check w Atmospheric Vent: 9D, 1/2 in Pipe Size, FNPT x FNPT, 18.7 gpm Flow Rate, Brass (MPN 9D-M3-1/2")
WATTS Dual Check w Atmospheric Vent: 9D, 3/4 in Pipe Size, FNPT x FNPT, 18.7 gpm Flow Rate, Brass (MPN 9D-M2-3/4")
Watts
WATTS Dual Check w Atmospheric Vent: 9D, 3/4 in Pipe Size, FNPT x FNPT, 18.7 gpm Flow Rate, Brass (MPN 9D-M2-3/4")

Lainnya dari Watts

Lihat semua Watts suku cadang
WATTS Dual Check Valve: SD-3, 3/8 in Pipe Size, FNPT x MNPT, 2.5 gpm Flow Rate, 4.5 in Overall Lg (MPN SD3-MF 3/8")
Watts
WATTS Dual Check Valve: SD-3, 3/8 in Pipe Size, FNPT x MNPT, 2.5 gpm Flow Rate, 4.5 in Overall Lg (MPN SD3-MF 3/8")
WATTS Backflow Preventer: SD-3, 3/8 in Pipe Size, FNPT x FNPT, 2.5 gpm Flow Rate, 3 in Overall Lg (MPN 3/8 SD3-FN)
Watts
WATTS Backflow Preventer: SD-3, 3/8 in Pipe Size, FNPT x FNPT, 2.5 gpm Flow Rate, 3 in Overall Lg (MPN 3/8 SD3-FN)
WATTS Dual Check Valve: SD-2, 3/8 in Pipe Size, Flare x Flare, 2.5 gpm Flow Rate, 3 in Overall Lg (MPN SD2-MF 3/8")
Watts
WATTS Dual Check Valve: SD-2, 3/8 in Pipe Size, Flare x Flare, 2.5 gpm Flow Rate, 3 in Overall Lg (MPN SD2-MF 3/8")
WATTS Dual Check with Atmospheric Vent: 9BD, 3/8 in Pipe Size, MNPT x MNPT, 2.5 gpm Flow Rate, Male
Watts
WATTS Dual Check with Atmospheric Vent: 9BD, 3/8 in Pipe Size, MNPT x MNPT, 2.5 gpm Flow Rate, Male
WATTS Backflow Preventer: SD-2, 3/8 in Pipe Size, FNPT x FNPT, 2.5 gpm Flow Rate, 3 in Overall Lg (MPN 3/8 SD2-FN)
Watts
WATTS Backflow Preventer: SD-2, 3/8 in Pipe Size, FNPT x FNPT, 2.5 gpm Flow Rate, 3 in Overall Lg (MPN 3/8 SD2-FN)
WATTS Backflow Preventer: SD-3, 3/8 in Pipe Size, MNPT x MNPT, 2.5 gpm Flow Rate, 3 in Overall Lg (MPN 3/8 SD3-MN)
Watts
WATTS Backflow Preventer: SD-3, 3/8 in Pipe Size, MNPT x MNPT, 2.5 gpm Flow Rate, 3 in Overall Lg (MPN 3/8 SD3-MN)
WATTS Dual Check with Atmospheric Vent: 9BD, 1/4 in Pipe Size, MNPT x MNPT, 2.5 gpm Flow Rate, Male
Watts
WATTS Dual Check with Atmospheric Vent: 9BD, 1/4 in Pipe Size, MNPT x MNPT, 2.5 gpm Flow Rate, Male
WATTS Backflow Preventer: SD-2, 3/8 in Pipe Size, MNPT x MNPT, 2.5 gpm Flow Rate, 3 in Overall Lg (MPN 3/8 SD2-MN)
Watts
WATTS Backflow Preventer: SD-2, 3/8 in Pipe Size, MNPT x MNPT, 2.5 gpm Flow Rate, 3 in Overall Lg (MPN 3/8 SD2-MN)