Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Watts LF8A Lead-Free Hose Bibb Vacuum Breaker, Female GHT x Male GHT - Lead-Free Hose Bibb Vacuum Breakers
WattsLead-Free Hose Bibb Vacuum Breakers

Watts LF8A Lead-Free Hose Bibb Vacuum Breaker, Female GHT x Male GHT

WATTS Atmospheric Vacuum Breaker tipe LF8A adalah katup pencegah aliran balik (back-siphonage) yang dirancang khusus untuk media air dengan rentang suhu 33°F hingga 180°F. Produk ini memiliki koneksi Female GHT x…

SKU 3G-OTH-439342

Merek
Watts
Item
LF8A Lead-Free Hose Bibb Vacuum Breaker, Female GHT x Male GHT
Kategori
Lead-Free Hose Bibb Vacuum Breakers
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Watts
Manufacturer Part Number
LF8A
Type
For Water Media, 33°F – 180°F, Female, GHT
For Media
Water
Standards
ANSI A112.1.3 (ASSE 1011)
Drain Type
Manual
Body Material
Copper Silicon Alloy
Seal Material
Rubber
Connection Type
Female GHT x Male GHT
Protection Type
Back-Siphonage
Freeze Protection
Yes
Security Mechanism
Non-Removable
Vacuum Breaker Style
Hose Bib Vacuum Breaker
Hazard Protection Level
High Health Hazard
Connection Type - Side 1
GHT
Connection Type - Side 2
GHT
Includes Atmospheric Vent
No Atmospheric Vent
Includes Drain Capability
Manual Drain
Connection Gender - Side 1
Female
Connection Gender - Side 2
Male
Includes Freeze Protection
Freeze Protection Included

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Watts Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

WATTS Atmospheric Vacuum Breaker tipe LF8A adalah katup pencegah aliran balik (back-siphonage) yang dirancang khusus untuk media air dengan rentang suhu 33°F hingga 180°F. Produk ini memiliki koneksi Female GHT x Male GHT, bodi dari Copper Silicon Alloy, dan segel karet. Sesuai standar ANSI A112.1.3 (ASSE 1011), alat ini memberikan perlindungan terhadap bahaya kesehatan tingkat tinggi (High Health Hazard) dan dilengkapi perlindungan beku (Freeze Protection) serta drain manual. Cocok untuk aplikasi sambungan selang air di lingkungan industri dan komersial di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa WATTS Atmospheric Vacuum Breaker LF8A digunakan?

WATTS LF8A adalah Hose Bibb Vacuum Breaker yang berfungsi mencegah back-siphonage pada sistem air. Produk ini melindungi pasokan air dari kontaminasi balik akibat tekanan negatif, khususnya pada sambungan selang (GHT). Dengan perlindungan High Health Hazard, alat ini cocok untuk aplikasi industri yang memerlukan keamanan air bersih.

Apa spesifikasi teknis WATTS LF8A?

Spesifikasi WATTS LF8A meliputi: media air, suhu operasi 33°F – 180°F, koneksi Female GHT x Male GHT, bodi Copper Silicon Alloy, segel karet, drain manual, perlindungan beku (Freeze Protection), dan mekanisme non-removable. Produk ini memenuhi standar ANSI A112.1.3 (ASSE 1011) untuk perlindungan back-siphonage.

Di mana beli WATTS LF8A di Indonesia?

Anda dapat membeli WATTS LF8A melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan kepabeanan untuk memastikan produk sampai ke lokasi Anda. Hubungi kami untuk minta penawaran.

Bagaimana cara memilih vacuum breaker yang tepat untuk sistem air industri?

Pilih vacuum breaker berdasarkan media (air), suhu operasi, jenis koneksi (GHT), dan tingkat bahaya. WATTS LF8A dengan perlindungan High Health Hazard dan sertifikasi ANSI A112.1.3 cocok untuk aplikasi back-siphonage. Pastikan juga ada perlindungan beku jika digunakan di area dengan suhu rendah.

Digunakan dalam

Aplikasi umum untuk Watts
Industrial burner gas safety systems — Watts HF2000 filters with GF-series seal kits maintain clean, regulated gas supply to burner pilot and main flame controls
Commercial heating and boiler installations — Modular filter assemblies support preventive maintenance and component replacement without full system shutdown
Process gas delivery pipelines — DN25 through DN125 filter bodies accommodate varying flow rates and inlet pressures across manufacturing and chemical processes
Gas pressure regulation benches — Multi-stage Watts filter platforms integrate with pressure reducers and safety shutoff valves in test and calibration environments
Equipment retrofit and upgrade projects — Available connection sizes and seal kits enable adaptation of newer Watts components into legacy gas control systems
Planned maintenance and spare-parts inventory — Filter seal kits allow facilities to stock consumables in advance, reducing downtime during scheduled gas system servicing

Watts Produk

3G Electric memasok Watts lead-free hose bibb vacuum breakers. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Hose bibb vacuum breaker for back-siphonage protection against high health hazards in water systems. Chrome-plated brass body with rubber seals, female GHT x male GHT connections, manual drain, and freeze protection. Includes break-away set screw security mechanism. Temperature range 33°F to 180°F. UPC listed
Watts
Hose bibb vacuum breaker for back-siphonage protection against high health hazards in water systems. Chrome-plated brass body with rubber seals, female GHT x male GHT connections, manual drain, and freeze protection. Includes break-away set screw security mechanism. Temperature range 33°F to 180°F. UPC listed
Brass hose bibb vacuum breaker with female GHT inlet and male GHT outlet. Provides back-siphonage protection for high health hazard water applications. Features manual drain, freeze protection, and a break-away set screw for security. Rated for water media from 33°F to 180°F. UPC listed
Watts
Brass hose bibb vacuum breaker with female GHT inlet and male GHT outlet. Provides back-siphonage protection for high health hazard water applications. Features manual drain, freeze protection, and a break-away set screw for security. Rated for water media from 33°F to 180°F. UPC listed
Hose bibb vacuum breaker with brass body and rubber seal. Provides back-siphonage protection for water systems, rated for high health hazard. Features manual drain and freeze protection. Connections: Female GHT x Male GHT. Temperature range: 33°F to 180°F. Complies with ANSI A112.1.3 (ASSE 1011)
Watts
Hose bibb vacuum breaker with brass body and rubber seal. Provides back-siphonage protection for water systems, rated for high health hazard. Features manual drain and freeze protection. Connections: Female GHT x Male GHT. Temperature range: 33°F to 180°F. Complies with ANSI A112.1.3 (ASSE 1011)
Brass hose bibb vacuum breaker with female GHT inlet and male GHT outlet. Provides back-siphonage protection for high health hazard water systems. Includes manual drain and freeze protection. Temperature range 33°F – 180°F. Certified to UPC standards
Watts
Brass hose bibb vacuum breaker with female GHT inlet and male GHT outlet. Provides back-siphonage protection for high health hazard water systems. Includes manual drain and freeze protection. Temperature range 33°F – 180°F. Certified to UPC standards
Brass hose bibb vacuum breaker with female GHT inlet and male GHT outlet. Provides back-siphonage protection for high health hazard applications. Includes manual drain and freeze protection. Temperature range 33°F to 180°F. Meets ANSI A112.1.3 (ASSE 1011)
Watts
Brass hose bibb vacuum breaker with female GHT inlet and male GHT outlet. Provides back-siphonage protection for high health hazard applications. Includes manual drain and freeze protection. Temperature range 33°F to 180°F. Meets ANSI A112.1.3 (ASSE 1011)
Brass hose bibb vacuum breaker with female GHT inlet and male GHT outlet. Provides back-siphonage protection for high health hazard water systems. Includes manual drain, freeze protection, and break-away set screw. Rated for water media from 33°F to 180°F. UPC certified
Watts
Brass hose bibb vacuum breaker with female GHT inlet and male GHT outlet. Provides back-siphonage protection for high health hazard water systems. Includes manual drain, freeze protection, and break-away set screw. Rated for water media from 33°F to 180°F. UPC certified

Lainnya dari Watts

Lihat semua Watts suku cadang
Hose bibb vacuum breaker for back-siphonage protection against high health hazards in water systems. Features manual drain, freeze protection, and non-removable security mechanism. Body is chrome-plated copper silicon alloy with rubber seal. Connections: Female GHT x Male GHT. Temperature range 33°F – 180°F. Complies with ANSI A112.1.3 (ASSE 1011)
Watts
Hose bibb vacuum breaker for back-siphonage protection against high health hazards in water systems. Features manual drain, freeze protection, and non-removable security mechanism. Body is chrome-plated copper silicon alloy with rubber seal. Connections: Female GHT x Male GHT. Temperature range 33°F – 180°F. Complies with ANSI A112.1.3 (ASSE 1011)
Lead-free hose bibb vacuum breaker for water media, with female GHT x male GHT connections. Brass body, silicone seal, manual drain, and freeze protection. Break-away set screw for security. IAPMO listed for high health hazard back-siphonage protection. Suitable for outdoor hose connections in irrigation and faucet applications
Watts
Lead-free hose bibb vacuum breaker for water media, with female GHT x male GHT connections. Brass body, silicone seal, manual drain, and freeze protection. Break-away set screw for security. IAPMO listed for high health hazard back-siphonage protection. Suitable for outdoor hose connections in irrigation and faucet applications
This lead-free hose bibb vacuum breaker from Watts prevents back-siphonage in potable water systems. Constructed with a brass body and rubber seals, it features female GHT x male GHT connections, manual drain capability, and freeze protection. Suitable for outdoor hose connections and irrigation systems, it is certified to NSF/ANSI 372 for high health hazard protection
Watts
This lead-free hose bibb vacuum breaker from Watts prevents back-siphonage in potable water systems. Constructed with a brass body and rubber seals, it features female GHT x male GHT connections, manual drain capability, and freeze protection. Suitable for outdoor hose connections and irrigation systems, it is certified to NSF/ANSI 372 for high health hazard protection
This hose bibb vacuum breaker prevents back-siphonage of contaminated water into potable supply lines. It features a reinforced thermoplastic body, rubber seals, manual drain, set screw security, and freeze protection. Rated for water media from 33°F to 180°F, it provides high health hazard protection per IAPMO standards. Typical applications include outdoor hose connections and irrigation systems
Watts
This hose bibb vacuum breaker prevents back-siphonage of contaminated water into potable supply lines. It features a reinforced thermoplastic body, rubber seals, manual drain, set screw security, and freeze protection. Rated for water media from 33°F to 180°F, it provides high health hazard protection per IAPMO standards. Typical applications include outdoor hose connections and irrigation systems
Brass-bodied hose bibb vacuum breaker for back-siphonage protection against high health hazards in water systems. Features female GHT inlet and male GHT outlet, manual drain, freeze protection, and a break-away set screw. Complies with NSF/ANSI 372 for lead-free requirements. Suitable for outdoor hose connections to prevent backflow into potable water
Watts
Brass-bodied hose bibb vacuum breaker for back-siphonage protection against high health hazards in water systems. Features female GHT inlet and male GHT outlet, manual drain, freeze protection, and a break-away set screw. Complies with NSF/ANSI 372 for lead-free requirements. Suitable for outdoor hose connections to prevent backflow into potable water
This lead-free hose bibb vacuum breaker prevents back-siphonage of contaminated water into potable water lines. Constructed with a brass body and silicone seals, it features female GHT x male GHT connections, a manual drain, and freeze protection. Certified to cCSAus B64.2 for high health hazard applications, it includes a break-away set screw for security. Suitable for outdoor hose connections and other water media applications within 33°F to 180°F
Watts
This lead-free hose bibb vacuum breaker prevents back-siphonage of contaminated water into potable water lines. Constructed with a brass body and silicone seals, it features female GHT x male GHT connections, a manual drain, and freeze protection. Certified to cCSAus B64.2 for high health hazard applications, it includes a break-away set screw for security. Suitable for outdoor hose connections and other water media applications within 33°F to 180°F