Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

WILKINS 1-975XL2 Reduced Pressure Zone Backflow Preventer - Zurn RPZ Backflow Preventers
WILKINSZurn RPZ Backflow Preventers

WILKINS 1-975XL2 Reduced Pressure Zone Backflow Preventer

WILKINS 975XL2 adalah Reduced Pressure Zone Backflow Preventer (RPZ) yang dirancang untuk melindungi sistem air bersih dari kontaminasi balik. Produk ini hadir dalam konfigurasi standar dengan material bronze, ukuran…

SKU 3G-OTH-440420

Juga terdaftar sebagai: 1975XL2 · 1 975XL2

Merek
WILKINS
Item
1-975XL2 Reduced Pressure Zone Backflow Preventer
Kategori
Zurn RPZ Backflow Preventers
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

WILKINS
Manufacturer Part Number
1-975XL2
Type
Std Configuration, Bronze
Pipe Size
1 in
Connection Type
FNPT
Shut-Off Valve Type
Ball Valve

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

WILKINS Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

WILKINS 975XL2 adalah Reduced Pressure Zone Backflow Preventer (RPZ) yang dirancang untuk melindungi sistem air bersih dari kontaminasi balik. Produk ini hadir dalam konfigurasi standar dengan material bronze, ukuran pipa 1 in, dan koneksi FNPT. Dilengkapi dengan katup penutup tipe ball valve, WILKINS 975XL2 merupakan pilihan andal untuk aplikasi komersial dan industri di Indonesia, termasuk untuk sistem ketel uap dan peralatan pembakaran.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi WILKINS 975XL2 Reduced Pressure Zone Backflow Preventer?

WILKINS 975XL2 berfungsi mencegah aliran balik air yang terkontaminasi ke dalam sistem air bersih. Produk ini menggunakan prinsip reduced pressure zone untuk menjaga tekanan air tetap aman. Cocok untuk instalasi pipa 1 in dengan koneksi FNPT.

Apa spesifikasi teknis WILKINS 975XL2?

Spesifikasi WILKINS 975XL2 meliputi: tipe konfigurasi standar, material bronze, ukuran pipa 1 in, koneksi FNPT, dan katup penutup tipe ball valve. Nomor komponen pabrikan adalah 1-975XL2.

Di mana beli WILKINS 975XL2 di Indonesia?

Anda dapat membeli WILKINS 975XL2 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Bagaimana cara memilih WILKINS 975XL2 yang tepat?

Pastikan ukuran pipa Anda 1 in dan koneksi yang dibutuhkan adalah FNPT. WILKINS 975XL2 tersedia dalam konfigurasi standar dengan material bronze dan katup ball valve. Periksa juga kebutuhan tekanan sistem Anda untuk memastikan kesesuaian.

Digunakan dalam

Aplikasi umum untuk WILKINS
Commercial water distribution — WILKINS 600XL series pressure reducing valves for regulating supply pressure in multi-story buildings.
Irrigation systems — WILKINS 975XL2 backflow preventers to protect potable water from contamination in agricultural setups.
Industrial process control — WILKINS 375ST reduced pressure principle backflow preventers for cross-connection control in manufacturing plants.
Municipal water treatment — WILKINS low-lead pressure regulators like the 1-600XL3DU for compliance with potable water standards.
HVAC systems — WILKINS 112-NR3XLDULU regulators for maintaining consistent water pressure in heating and cooling loops.
Fire protection systems — WILKINS backflow preventers for backflow prevention in sprinkler and standpipe systems.

WILKINS Produk

3G Electric memasok WILKINS zurn rpz backflow preventers. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Reduced pressure zone backflow preventer with bronze body and FNPT connections. Equipped with ball valve shut-off. Used in commercial, industrial, and municipal water systems to protect potable water from backflow contamination
WILKINS
Reduced pressure zone backflow preventer with bronze body and FNPT connections. Equipped with ball valve shut-off. Used in commercial, industrial, and municipal water systems to protect potable water from backflow contamination
Reduced pressure zone backflow preventer in standard configuration. Bronze body with female NPT connections and ball valve shut-offs. Used in water supply systems to prevent backflow from high-hazard cross-connections
WILKINS
Reduced pressure zone backflow preventer in standard configuration. Bronze body with female NPT connections and ball valve shut-offs. Used in water supply systems to prevent backflow from high-hazard cross-connections
Reduced pressure zone backflow preventer in standard configuration. Constructed of bronze with female NPT connections and ball valve shut-off. Used to protect potable water supplies from cross-connection contamination in commercial, industrial, and irrigation systems
WILKINS
Reduced pressure zone backflow preventer in standard configuration. Constructed of bronze with female NPT connections and ball valve shut-off. Used to protect potable water supplies from cross-connection contamination in commercial, industrial, and irrigation systems
The WILKINS 975XL2 is a reduced pressure zone backflow preventer in standard configuration. Constructed of bronze with female NPT connections, it includes ball valve shut-off valves. This assembly is used in water supply systems to prevent backflow from cross-connections
WILKINS
The WILKINS 975XL2 is a reduced pressure zone backflow preventer in standard configuration. Constructed of bronze with female NPT connections, it includes ball valve shut-off valves. This assembly is used in water supply systems to prevent backflow from cross-connections
Reduced pressure zone backflow preventer with bronze body and FNPT connections. Standard configuration with ball valve shut-off. Used in water systems to prevent backflow in high-hazard cross-connections such as irrigation, fire sprinkler, or boiler feed lines
WILKINS
Reduced pressure zone backflow preventer with bronze body and FNPT connections. Standard configuration with ball valve shut-off. Used in water systems to prevent backflow in high-hazard cross-connections such as irrigation, fire sprinkler, or boiler feed lines
Reduced pressure zone backflow preventer in standard configuration. Bronze body with 1-inch female NPT connections and ball valve shut-off. Used to protect potable water supplies from contamination due to backflow or backsiphonage in commercial, industrial, and municipal water systems
WILKINS
Reduced pressure zone backflow preventer in standard configuration. Bronze body with 1-inch female NPT connections and ball valve shut-off. Used to protect potable water supplies from contamination due to backflow or backsiphonage in commercial, industrial, and municipal water systems

Lainnya dari WILKINS

Lihat semua WILKINS suku cadang
The WILKINS 375 is a reduced pressure zone backflow preventer with a standard configuration. It features a glass-filled nylon body, flange connections, and ball valve shut-offs. This device is used in commercial, industrial, and municipal water systems to protect potable water from contamination due to backflow
WILKINS
The WILKINS 375 is a reduced pressure zone backflow preventer with a standard configuration. It features a glass-filled nylon body, flange connections, and ball valve shut-offs. This device is used in commercial, industrial, and municipal water systems to protect potable water from contamination due to backflow
Reduced pressure zone backflow preventer with bronze body and FNPT connections. Equipped with ball valve shut-off type. Used to protect potable water supplies from cross-connection contamination in commercial, industrial, and irrigation systems
WILKINS
Reduced pressure zone backflow preventer with bronze body and FNPT connections. Equipped with ball valve shut-off type. Used to protect potable water supplies from cross-connection contamination in commercial, industrial, and irrigation systems
WILKINS
WILKINS
Reduced pressure principle backflow preventer in standard configuration. Body constructed of 304L stainless steel with flange connections. Equipped with an outside stem and yoke (OSY) gate valve for shut-off. Used in commercial, industrial, and municipal water systems to protect potable water supplies from cross-connection contamination
Reduced pressure zone backflow preventer with glass-filled nylon body and female NPT connections. Standard configuration with ball valve shut-off. Used in commercial, industrial, and irrigation systems to protect potable water from cross-connection contamination
WILKINS
Reduced pressure zone backflow preventer with glass-filled nylon body and female NPT connections. Standard configuration with ball valve shut-off. Used in commercial, industrial, and irrigation systems to protect potable water from cross-connection contamination
Reduced pressure zone backflow preventer with flange connections and ball valve shut-off. Body constructed of glass-filled nylon in standard configuration. Used to protect potable water supplies from contamination in high-hazard cross-connection applications
WILKINS
Reduced pressure zone backflow preventer with flange connections and ball valve shut-off. Body constructed of glass-filled nylon in standard configuration. Used to protect potable water supplies from contamination in high-hazard cross-connection applications
This WILKINS 975XL reduced pressure zone backflow preventer is a standard configuration unit with a bronze body. It features 3/4 inch FNPT connections and a ball valve shut-off type. Designed to protect potable water supplies from contamination due to back-siphonage or back-pressure, it is suitable for high-hazard cross-connections in commercial, industrial, and municipal water systems
WILKINS
This WILKINS 975XL reduced pressure zone backflow preventer is a standard configuration unit with a bronze body. It features 3/4 inch FNPT connections and a ball valve shut-off type. Designed to protect potable water supplies from contamination due to back-siphonage or back-pressure, it is suitable for high-hazard cross-connections in commercial, industrial, and municipal water systems
Reduced pressure zone backflow preventer with bronze body, 2 in FNPT connections, and ball valve shut-offs. Used in commercial and industrial plumbing systems to protect potable water supplies from backflow contamination
WILKINS
Reduced pressure zone backflow preventer with bronze body, 2 in FNPT connections, and ball valve shut-offs. Used in commercial and industrial plumbing systems to protect potable water supplies from backflow contamination
This Zurn RPZ backflow preventer features a glass-filled nylon body with FNPT connections and a 1 in pipe size. It includes an integrated strainer and a ball valve shut-off type. Suitable for protecting potable water supplies in commercial, industrial, and irrigation systems where high-hazard cross-connections exist
WILKINS
This Zurn RPZ backflow preventer features a glass-filled nylon body with FNPT connections and a 1 in pipe size. It includes an integrated strainer and a ball valve shut-off type. Suitable for protecting potable water supplies in commercial, industrial, and irrigation systems where high-hazard cross-connections exist