Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

WILKINS 114UFMX1UF-700XL Potable Water Dual Check Backflow Preventer - Potable Water Dual Check Backflow Preventers
WILKINSPotable Water Dual Check Backflow Preventers

WILKINS 114UFMX1UF-700XL Potable Water Dual Check Backflow Preventer

WILKINS Backflow Preventer tipe 700XL adalah potable water dual check backflow preventer yang dirancang untuk melindungi sistem air bersih dari kontaminasi balik. Produk ini memiliki koneksi FNPT x FNPT, material…

SKU 3G-OTH-437193

Juga terdaftar sebagai: 114UFMX1UF700XL · 114UFMX1UF 700XL

Merek
WILKINS
Item
114UFMX1UF-700XL Potable Water Dual Check Backflow Preventer
Kategori
Potable Water Dual Check Backflow Preventers
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

WILKINS
Manufacturer Part Number
114UFMX1UF-700XL
Type
FNPT x FNPT, Bronze, Delrin
Pipe Size
1 1/4 in
Flow Rate
70 gpm
Connection Type
FNPT x FNPT

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

WILKINS Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

WILKINS Backflow Preventer tipe 700XL adalah potable water dual check backflow preventer yang dirancang untuk melindungi sistem air bersih dari kontaminasi balik. Produk ini memiliki koneksi FNPT x FNPT, material bronze dan Delrin, dengan ukuran pipa 1 1/4 in dan flow rate 70 gpm. Cocok untuk aplikasi perpipaan industri dan komersial di Indonesia yang memerlukan perlindungan backflow andal.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi WILKINS Backflow Preventer 700XL?

WILKINS Backflow Preventer 700XL berfungsi sebagai dual check backflow preventer untuk mencegah aliran balik air kotor ke sistem air bersih (potable water). Produk ini menggunakan dua katup periksa internal untuk memberikan perlindungan ganda, ideal untuk instalasi perpipaan di gedung, pabrik, atau fasilitas komersial.

Apa spesifikasi teknis WILKINS 700XL?

Spesifikasi WILKINS 700XL meliputi: tipe FNPT x FNPT, material bronze dan Delrin, ukuran pipa 1 1/4 in, flow rate 70 gpm, dan nomor part pabrikan 114UFMX1UF-700XL. Produk ini dirancang untuk sistem air bersih dan memenuhi standar industri untuk pencegahan backflow.

Di mana beli WILKINS Backflow Preventer 700XL di Indonesia?

Anda dapat membeli WILKINS Backflow Preventer 700XL melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai sehingga Anda bisa mendapatkan produk original dengan mudah. Hubungi kami untuk minta penawaran.

Bagaimana cara memilih WILKINS Backflow Preventer yang tepat?

Pilih WILKINS Backflow Preventer berdasarkan ukuran pipa dan flow rate yang dibutuhkan. Untuk model 700XL, ukuran pipa 1 1/4 in dan flow rate 70 gpm cocok untuk aplikasi komersial ringan hingga menengah. Pastikan koneksi FNPT x FNPT sesuai dengan sistem perpipaan Anda. Konsultasikan dengan teknisi untuk instalasi yang benar.

Digunakan dalam

Aplikasi umum untuk WILKINS
Commercial water distribution — WILKINS 600XL series pressure reducing valves for regulating supply pressure in multi-story buildings.
Irrigation systems — WILKINS 975XL2 backflow preventers to protect potable water from contamination in agricultural setups.
Industrial process control — WILKINS 375ST reduced pressure principle backflow preventers for cross-connection control in manufacturing plants.
Municipal water treatment — WILKINS low-lead pressure regulators like the 1-600XL3DU for compliance with potable water standards.
HVAC systems — WILKINS 112-NR3XLDULU regulators for maintaining consistent water pressure in heating and cooling loops.
Fire protection systems — WILKINS backflow preventers for backflow prevention in sprinkler and standpipe systems.

WILKINS Produk

3G Electric memasok WILKINS potable water dual check backflow preventers. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
WILKINS Backflow Preventer: 700XL, 1 in Pipe Size, FNPT x FNPT, 40 gpm Flow Rate, 4.5 in Overall Lg (MPN 1UFMX34UF-700XL)
WILKINS
WILKINS Backflow Preventer: 700XL, 1 in Pipe Size, FNPT x FNPT, 40 gpm Flow Rate, 4.5 in Overall Lg (MPN 1UFMX34UF-700XL)
WILKINS Dual Check Valve: 700XL, 3/4 in Pipe Size, FNPT x FNPT, 25 gpm Flow Rate, 4.5 in Overall Lg (MPN 34UFX34F-700XL)
WILKINS
WILKINS Dual Check Valve: 700XL, 3/4 in Pipe Size, FNPT x FNPT, 25 gpm Flow Rate, 4.5 in Overall Lg (MPN 34UFX34F-700XL)
WILKINS Dual Check Valve: 705, 1 in Pipe Size, FNPT x FNPT, 40 gpm Flow Rate, 4.5 in Overall Lg, NPT (MPN 1UFMX1F-705)
WILKINS
WILKINS Dual Check Valve: 705, 1 in Pipe Size, FNPT x FNPT, 40 gpm Flow Rate, 4.5 in Overall Lg, NPT (MPN 1UFMX1F-705)
This dual check backflow preventer is designed for carbonated water lines in commercial food service applications. It features 3/8 inch FNPT x FNPT connections, a flow rate of 2.2 gpm, and an overall length of 1 inch. The device helps protect potable water supplies from backflow contamination
WILKINS
This dual check backflow preventer is designed for carbonated water lines in commercial food service applications. It features 3/8 inch FNPT x FNPT connections, a flow rate of 2.2 gpm, and an overall length of 1 inch. The device helps protect potable water supplies from backflow contamination

Lainnya dari WILKINS

Lihat semua WILKINS suku cadang
This WILKINS dual check backflow preventer is designed for potable water systems to prevent reverse flow from cross-connections. It features a 1 in pipe size with FNPT x FNPT connections and NPT threads. The valve has a flow rate of 40 gpm and an overall length of 4.5 in. Typical applications include commercial and residential plumbing where backflow protection is required
WILKINS
This WILKINS dual check backflow preventer is designed for potable water systems to prevent reverse flow from cross-connections. It features a 1 in pipe size with FNPT x FNPT connections and NPT threads. The valve has a flow rate of 40 gpm and an overall length of 4.5 in. Typical applications include commercial and residential plumbing where backflow protection is required
This WILKINS dual check backflow preventer is designed for potable water systems to prevent reverse flow and protect drinking water supplies. It features 1 in FNPT x FNPT connections, a flow rate of 40 gpm, and an overall length of 4.5 in. Suitable for use in residential and commercial plumbing applications where backflow prevention is required
WILKINS
This WILKINS dual check backflow preventer is designed for potable water systems to prevent reverse flow and protect drinking water supplies. It features 1 in FNPT x FNPT connections, a flow rate of 40 gpm, and an overall length of 4.5 in. Suitable for use in residential and commercial plumbing applications where backflow prevention is required
This WILKINS dual check backflow preventer is designed for potable water systems to prevent reverse flow contamination. It features 1-inch MNPT x FNPT connections, a flow rate of 40 gpm, and an overall length of 4.5 inches. Suitable for residential and light commercial water supply lines
WILKINS
This WILKINS dual check backflow preventer is designed for potable water systems to prevent reverse flow contamination. It features 1-inch MNPT x FNPT connections, a flow rate of 40 gpm, and an overall length of 4.5 inches. Suitable for residential and light commercial water supply lines
The WILKINS 700XL is a potable water dual check backflow preventer with 1-inch FNPT x FNPT connections and a flow rate of 40 gpm. It is used in residential or commercial water lines to prevent backflow contamination caused by pressure changes. Overall length is 1 inch
WILKINS
The WILKINS 700XL is a potable water dual check backflow preventer with 1-inch FNPT x FNPT connections and a flow rate of 40 gpm. It is used in residential or commercial water lines to prevent backflow contamination caused by pressure changes. Overall length is 1 inch
The WILKINS 700XL is a 1-inch dual check backflow preventer with FNPT x MNPT connections and a 40 gpm flow rate. It is designed for potable water systems to prevent backflow contamination in residential and commercial plumbing, irrigation, and boiler feed applications
WILKINS
The WILKINS 700XL is a 1-inch dual check backflow preventer with FNPT x MNPT connections and a 40 gpm flow rate. It is designed for potable water systems to prevent backflow contamination in residential and commercial plumbing, irrigation, and boiler feed applications
This WILKINS dual check backflow preventer is designed for potable water systems to prevent reverse flow. It features 3/4 in FNPT x FNPT connections, a flow rate of 25 gpm, and an overall length of 4.5 in. Suitable for use in residential and commercial plumbing applications such as irrigation and boiler feed lines
WILKINS
This WILKINS dual check backflow preventer is designed for potable water systems to prevent reverse flow. It features 3/4 in FNPT x FNPT connections, a flow rate of 25 gpm, and an overall length of 4.5 in. Suitable for use in residential and commercial plumbing applications such as irrigation and boiler feed lines
WILKINS Dual Check Valve: 700XL, 3/4 in Pipe Size, MNPT x FNPT, 25 gpm Flow Rate, 4.5 in Overall Lg (MPN 34MX34UF-700XL)
WILKINS
WILKINS Dual Check Valve: 700XL, 3/4 in Pipe Size, MNPT x FNPT, 25 gpm Flow Rate, 4.5 in Overall Lg (MPN 34MX34UF-700XL)
WILKINS Backflow Preventer: 700XLFP, 1 in Pipe Size, FNPT x FNPT, 52 gpm Flow Rate, Bronze, Delrin (MPN 1UFX1F-700XLFP)
WILKINS
WILKINS Backflow Preventer: 700XLFP, 1 in Pipe Size, FNPT x FNPT, 52 gpm Flow Rate, Bronze, Delrin (MPN 1UFX1F-700XLFP)