WOHLER Penetration Temperature Probe dengan tipe K termokopel presisi tinggi untuk aplikasi permukaan industri. Probe ini menawarkan akurasi ±0.3% dan rentang pengukuran suhu dari -35°C hingga 600°C (-32°F hingga…

SKU 3G-OTH-178954

Merek
WOHLER
Item
Type K Thermocouple for Surface Applications
Kategori
Thermocouples for Surface Applications
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

WOHLER
Manufacturer Part Number
6629
Type
±0.3% Accuracy, Type K
Accuracy
±0.3 %
Handle Type
Straight

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

WOHLER Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

WOHLER Penetration Temperature Probe dengan tipe K termokopel presisi tinggi untuk aplikasi permukaan industri. Probe ini menawarkan akurasi ±0.3% dan rentang pengukuran suhu dari -35°C hingga 600°C (-32°F hingga 1.202°F), ideal untuk pengukuran suhu pada permukaan ketel uap, pipa, atau komponen pembakar. Dengan gagang lurus (straight handle) dan nomor model 6629, probe ini merupakan alat ukur andal untuk teknisi pemeliharaan di sektor kelapa sawit, semen, dan pengolahan makanan. Cari termokopel tipe K untuk aplikasi permukaan? WOHLER 6629 adalah pilihan tepat.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi WOHLER Penetration Temperature Probe 6629?

WOHLER Penetration Temperature Probe 6629 adalah termokopel tipe K dengan akurasi ±0.3%. Rentang suhu -35°C hingga 600°C (-32°F hingga 1.202°F). Gagang lurus (straight handle) memudahkan pengukuran pada permukaan industri.

Untuk apa WOHLER probe penetrasi suhu digunakan?

Probe ini digunakan untuk mengukur suhu permukaan pada peralatan industri seperti ketel uap, pipa, dan komponen pembakar. Cocok untuk aplikasi pemeliharaan dan pengujian di pabrik kelapa sawit, semen, dan pengolahan makanan.

Di mana beli WOHLER 6629 di Indonesia?

Anda dapat membeli WOHLER Penetration Temperature Probe 6629 melalui 3G Electric. Kami adalah distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia, menangani logistik dan bea cukai untuk memastikan pengiriman tepat waktu.

Bagaimana cara memilih termokopel untuk aplikasi permukaan?

Pilih termokopel tipe K seperti WOHLER 6629 jika Anda memerlukan akurasi ±0.3% dan rentang suhu luas (-35°C hingga 600°C). Pastikan gagang lurus untuk akses mudah ke permukaan. Cocok untuk pengukuran pada ketel uap dan pipa industri.

Digunakan dalam

Aplikasi umum untuk WOHLER
Plumbing and drainage inspection — WOHLER VIS 200 pipe inspection camera system for locating blockages in 6-inch pipes
HVAC system diagnostics — WOHLER thermocouple thermometer MPN 6622 for measuring flue gas temperatures in boilers
Industrial process monitoring — WOHLER wall temperature probe MPN 4651 for checking pipe surface temperatures in gas applications
Environmental humidity assessment — WOHLER dew point indicator MPN 6808 for evaluating condensation risk in storage facilities
Sewer line maintenance — WOHLER VIS 350 PLUS with locator for mapping underground pipe defects up to 8 inches diameter
Quality control in manufacturing — WOHLER penetration temperature probe MPN 6629 for verifying material temperatures during processing

WOHLER Produk

3G Electric memasok WOHLER thermocouples for surface applications. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Type K thermocouple for gas applications with ±1°C accuracy and 5.1-inch probe length. Straight handle design. Suitable for surface temperature measurement on walls, flues, and exhaust systems in industrial heating and HVAC contexts
WOHLER
Type K thermocouple for gas applications with ±1°C accuracy and 5.1-inch probe length. Straight handle design. Suitable for surface temperature measurement on walls, flues, and exhaust systems in industrial heating and HVAC contexts
Thermocouple meter for Type K thermocouples, measuring from -328°F to 2,498°F with ±0.3% + 0.7°F accuracy. Features Min/Max temperature testing functions and cabled data output for remote monitoring. Suitable for industrial process temperature measurement, HVAC diagnostics, and laboratory testing
WOHLER
Thermocouple meter for Type K thermocouples, measuring from -328°F to 2,498°F with ±0.3% + 0.7°F accuracy. Features Min/Max temperature testing functions and cabled data output for remote monitoring. Suitable for industrial process temperature measurement, HVAC diagnostics, and laboratory testing
Thermocouple for gas applications with ±0.3% accuracy and a 5.1-inch probe length. Features a straight handle type. Suitable for temperature measurement in flue gas, HVAC, boiler, and combustion system diagnostics
WOHLER
Thermocouple for gas applications with ±0.3% accuracy and a 5.1-inch probe length. Features a straight handle type. Suitable for temperature measurement in flue gas, HVAC, boiler, and combustion system diagnostics
This handheld meter measures ambient temperature from 4°F to 140°F and relative humidity from 0% to 100%. It is used for spot-checking surface temperatures and air conditions in HVAC, facility maintenance, and industrial environments. Dimensions: 7 in x 2 in x 3 in. Battery not included
WOHLER
This handheld meter measures ambient temperature from 4°F to 140°F and relative humidity from 0% to 100%. It is used for spot-checking surface temperatures and air conditions in HVAC, facility maintenance, and industrial environments. Dimensions: 7 in x 2 in x 3 in. Battery not included
Type K thermocouple probe for surface temperature measurement on pipes, plates, or machinery. Features a plastic handle and 4.72-inch probe length. Accuracy ±0.5 °C + 0.3 % of reading from -40 to 500 °C. Suitable for HVAC, industrial maintenance, and quality control applications
TESTO
Type K thermocouple probe for surface temperature measurement on pipes, plates, or machinery. Features a plastic handle and 4.72-inch probe length. Accuracy ±0.5 °C + 0.3 % of reading from -40 to 500 °C. Suitable for HVAC, industrial maintenance, and quality control applications
This cabled instrument measures ambient temperature and dew point over a range of -40°F to 212°F. It is used to monitor condensation risk in compressed air systems, drying processes, and climate-controlled facilities. Dimensions: 4.8 in x 2.4 in x 1 in. Battery not included
WOHLER
This cabled instrument measures ambient temperature and dew point over a range of -40°F to 212°F. It is used to monitor condensation risk in compressed air systems, drying processes, and climate-controlled facilities. Dimensions: 4.8 in x 2.4 in x 1 in. Battery not included

Lainnya dari WOHLER

Lihat semua WOHLER suku cadang
Type K thermocouple for surface temperature measurement. Accuracy ±0.3%. PTFE cable length 3 ft 6 in. Maximum wire gauge 2.4 mm. Process mounting via hose clamp. Suitable for pipe, duct, and equipment surface monitoring
WOHLER
Type K thermocouple for surface temperature measurement. Accuracy ±0.3%. PTFE cable length 3 ft 6 in. Maximum wire gauge 2.4 mm. Process mounting via hose clamp. Suitable for pipe, duct, and equipment surface monitoring