Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

Pembakar industri FBR GAS X4/2CE adalah gas burner dua tahap (2 stages) yang dirancang untuk aplikasi ketel uap dan oven industri. Dengan daya termal maksimal 232 kW dan daya minimal 64 kW, burner ini memiliki…

SKU 3G-FBR-00498

Juga terdaftar sebagai: 00270031 · 002700 31 · 002700-31

Merek
FBR
Item
variant_2
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
19 kg
stage
2 stages
fuel type
Gas
nozzle mm
160
fan motor w
200
power kw max
232
power kw min
64
ip protection
IP 40
noisiness dba
66-69
gas consumption
6.4/11.6-23.2
electrical supply
1
power supply info
50Hz
current absorption a
1.35
thermal power mcal h
55/100-200
nominal electric power w
226
max combustion air temp c
60

Konten Lembar Data

GAS BURNERS TWO STAGES SK071055_B_en GAS BURNERS TWO STAGES GAS X1/2CE - GAS X2/2CE - GAS X3/2CE - GAS X4/2CE - GAS X5/2CE Gas burners two stages with: aluminum body, fan at high pressurisation and combustion head with adjustment at high efficiency and high flame stability and protection cover with noise reduction plate. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled, electrically linked and tested; complete of two stages working valve with flow adjustment, safety valve, minimum gas pressure switch and stabiliser filter of gas pressure. Versions F with cover of protection in steel and specific features for the application on industrial ovens and bakery ovens. Complete of connector plug / socket 7 poles, flange and gasket for installation on generator. Fig. 1 GAS X4/2CE GAS X1/2CE - GAS X2/2CE - GAS X3/2CE - GAS X4/2CE - GAS X5/2CE GAS BURNERS TWO STAGES SK071055_B_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS X1/2CE - GAS X2/2CE MODEL GAS X1/2CE GAS X2/2CE Thermal power min. - max. * [Mcal/h] 15.5/20-50 21/35-80 Thermal power min. - max. * [kW] 18/23.2-58.1 24.4/40.7-93 Gas flow G20 (NATURAL GAS) min. - max. * [Nm³/h] 1.8/2.3-5.8 2.5/4.1-9.4 Gas flow G31 (L.P.G.) min. - max. * [Nm³/h] 0.7/0.9-2.3 0.9/1.6-3.6 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) / I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 Min. pressure gas train D1/2"-S NATURAL GAS/L.P.G. ** [mbar] 14/31 - Min. pressure gas train D3/4"-S NATURAL GAS/L.P.G. ** [mbar] - 14/28 Max. pressure at the entry of valves (Pe. max) [mbar] 60 360 Nominal electric power [W] 110 130 Fan motor [W] 75 75 Nominal motor current absorption [A] 0.55 0.55 Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 IP 40 Noisiness *** min. - max. [dB(A)] 60-61 61-62 Burner weight **** [kg] 11 11.5 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - method of control Class 3 - The tollerance of the measured pressure can be taken equal to ± 1 [dB(A)]). **** For burner with cover in steel (F) add 3 kg to the weight. [mbar] 3 GAS X1/2 GAS X2/2 2 1 0 -1 0 50 100 [kW] 0 50 100 [Mcal/h] Fig. 2 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS X1/2CE - GAS X2/2CE - GAS X3/2CE - GAS X4/2CE - GAS X5/2CE GAS BURNERS TWO STAGES SK071055_B_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS X3/2CE - GAS X4/2CE MODEL GAS X3/2CE GAS X4/2CE Thermal power min. - max. * [Mcal/h] 30/60-150 55/100-200 Thermal power min. - max. * [kW] 34.9/69.8-174 64/116-232 Gas flow G20 (NATURAL GAS) min. - max. * [Nm³/h] 3.5/7-17.4 6.4/11.6-23.2 Gas flow G31 (L.P.G.) min. - max. * [Nm³/h] 1.3/2.7-6.5 2.5/4.5-9 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) / I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 Min. pressure gas train D1"-S NATURAL GAS/L.P.G. ** [mbar] 14/31 14/21 Min. pressure gas train D1"1/4-S NATURAL GAS/L.P.G. ** [mbar] 11/30 11/19 Min. pressure gas train D1"1/2-S NATURAL GAS/L.P.G. ** [mbar] 10/28 8/17 Max. pressure at the entry of valves (Pe. max) [mbar] 360 360 Nominal electric power [W] 200 226 Fan motor [W] 110 200 Nominal motor current absorption [A] 0.77 1.35 Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 IP 40 Noisiness *** min. - max. [dB(A)] 66-69 66-69 Burner weight **** [kg] 16 19 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - method of control Class 3 - The tollerance of the measured pressure can be taken equal to ± 1 [dB(A)]). **** For burner with cover in steel (F) add 3 kg to the weight. [PEDU] 6 5 4 3 2 GAS X3/2 GAS X4/2 1 0 -1 0 50 100 150 200 250 [ kW ] 0 50 100 150 200 [Mcal/h] Fig. 3 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS X1/2CE - GAS X2/2CE - GAS X3/2CE - GAS X4/2CE - GAS X5/2CE GAS BURNERS TWO STAGES SK071055_B_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS X5/2CE MODEL GAS X5/2CE Thermal power min. - max. * [Mcal/h] 70/130-300 Thermal power min. - max. * [kW] 81.4/151-349 Gas flow G20 (NATURAL GAS) min. - max. * [Nm³/h] 8.2/15.2-35 Gas flow G31 (L.P.G.) min. - max. * [Nm³/h] 3.2/5.8-13.5 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) / I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Min. pressure gas train D1"-S NATURAL GAS/L.P.G. ** [mbar] 27/33 Min. pressure gas train D1"1/4-S NATURAL GAS/L.P.G. ** [mbar] 16/25 Min. pressure gas train D1"1/2-S NATURAL GAS/L.P.G. ** [mbar] 15/12 Max. pressure at the entry of valves (Pe. max) [mbar] 360 Nominal electric power [W]…

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pembakar industri FBR GAS X4/2CE adalah gas burner dua tahap (2 stages) yang dirancang untuk aplikasi ketel uap dan oven industri. Dengan daya termal maksimal 232 kW dan daya minimal 64 kW, burner ini memiliki konsumsi gas 6,4/11,6–23,2 Nm³/h serta perlindungan IP 40. Dilengkapi fan bermotor 200 W, bodi aluminium, dan katup gas dua tahap, produk ini cocok untuk kebutuhan pembakaran gas alam atau LPG di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi FBR GAS X4/2CE gas burner?

FBR GAS X4/2CE adalah gas burner dua tahap dengan daya termal 64–232 kW, konsumsi gas 6,4/11,6–23,2 Nm³/h, nozzle 160 mm, dan berat 19 kg. Burner ini menggunakan catu daya 1 fase 50 Hz dengan arus 1,35 A dan perlindungan IP 40.

Untuk apa FBR GAS X4/2CE digunakan?

Burner ini digunakan pada ketel uap (boiler) dan oven industri, termasuk oven roti. Dengan sistem dua tahap, burner cocok untuk aplikasi yang memerlukan pengaturan daya termal antara 64 kW hingga 232 kW, serta mendukung bahan bakar gas alam atau LPG.

Bagaimana cara memilih FBR gas burner yang tepat?

Pilih berdasarkan daya termal yang dibutuhkan: FBR GAS X4/2CE memiliki rentang daya 64–232 kW. Pastikan tekanan gas minimum sesuai spesifikasi (untuk gas alam/LPG) dan perhatikan ukuran nozzle 160 mm serta suplai listrik 1 fase 50 Hz.

Di mana beli FBR GAS X4/2CE di Indonesia?

Anda dapat membeli FBR GAS X4/2CE melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
X GAS X4 CE TC | Variant: variant_2 | Subgroup: Burner
FBR
X GAS X4 CE TC | Variant: variant_2 | Subgroup: Burner
X GAS X4/2 CE TL | Variant: variant_2 | Subgroup: Burner
FBR
X GAS X4/2 CE TL | Variant: variant_2 | Subgroup: Burner
X GAS X4 CE TL | Variant: variant_2 | Subgroup: Burner
FBR
X GAS X4 CE TL | Variant: variant_2 | Subgroup: Burner
X GAS X4/2 CE TC | Variant: metano | Subgroup: Burner
FBR
X GAS X4/2 CE TC | Variant: metano | Subgroup: Burner
GAS X4 CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X4 CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS X4/2 CE-LX4 TL Cl. | Variant: variant_2 | Subgroup: Burner
FBR
GAS X4/2 CE-LX4 TL Cl. | Variant: variant_2 | Subgroup: Burner

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL