Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

FBR GM X4 adalah pembakar dual fuel gas/light-oil single stage yang dirancang untuk aplikasi industri berat seperti ketel uap dan tungku pemanas. Dengan rentang daya termal 99,5–199,5 Mcal/h (116–232 kW), konsumsi…

SKU 3G-FBR-00164

Juga terdaftar sebagai: 00412931 · 004129 31 · 004129-31

Merek
FBR
Item
variant_2
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
19 kg
stage
Single stage
fuel type
Dual fuel gas/light oil
nozzle mm
160
fan motor w
200
power kw max
232
power kw min
116
ip protection
IP 40
noisiness dba
67-68
power kcal max
200
power kcal min
100
gas consumption
11,6-23,2
electrical supply
1
power supply info
1/N~230V-50Hz
thermal power mcal h
99,5-199,5
nominal electric power w
250
max combustion air temp c
60

Konten Lembar Data

DUAL FUEL GAS/LIGHT-OIL BURNERS AT SINGLE SK073501_A_en STAGE DUAL FUEL GAS/LIGHT-OIL BURNERS AT SINGLE STAGE GM X0 - GM X1 - GM X3 - GM X4 Dual fuel gas/light-oil burners at single stage. They are composed by: aluminium frame, fan at high pressurisation, protection cover with noise reduction plate and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled and tested; complete of single-stage working valve with flow adjustment, safety valve, minimum gas pressure switch. Complete of plug/socket 7 poles, flange and gasket for installation on generator. Complete of nozzle, flexible pipes and line filter. Fig. 1 GM X4 GM X0 - GM X1 - GM X3 - GM X4 DUAL FUEL GAS/LIGHT-OIL BURNERS AT SINGLE SK073501_A_en STAGE TECHNICAL DATA AND OPERATING RANGE DIAGRAM GM X0 - GM X1 - GM X3 - GM X4 MODEL GM X0 GM X1 GM X3 GM X4 Thermal power min. - max. * [Mcal/h] 19-29 24,5-60 49.5-129,5 99,5-199,5 Thermal power min. - max. * [kW] 22,6-34,3 29-69,8 58.1-151 116-232 Gas flow G20 (NATURAL GAS) min. - max. * [Nm³/h] 2,3-3,4 2,9-7 5.8-15.2 11,6-23,2 Gas flow G31 (L.P.G.) min. - max. * [Nm³/h] 0,9-1,3 1,1-2,7 2.2-5.9 4,5-9 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R)B/I3B/P,I3+,I3P,I3B,I3R Minimum pressure gas train D1/2" - S NATURAL GAS/LPG ** [mbar] 10/20 28/33 - - Minimum pressure gas train D1" - S NATURAL GAS/LPG ** [mbar] - - 21/30 18/33 Maximum pressure at the entry of valves (Pe. max) 60mbar SIT; 360mbar DUNGS LIGHT-OIL flow min. - max. * [kg/h] 2-3 2,5-6 5-13 10-20 Fuel: LIGHT-OIL 1,5°E at 20°C= 6,2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) one stage Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 60 60 Nominal electric power [W] 150 150 200 250 Fan motor [W] 100 100 150 200 Nominal absorption fan motor [A] 0,72 0,72 1,1 1,35 Power supply: 1/N~230V-50Hz Electric protection degree: IP 40 IP 40 IP 40 IP 40 Noisiness *** min. - max. [dB(A)] 56-58 57-59 65-66 67-68 Burner weight [kg] 16 17 18 19 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). [mbar] 4.8 4.4 4.0 3.6 3.2 2.8 2.4 2.0 1.6 1.2 0.8 0.4 GM X0 GM X1 GM X3 GM X4 0 -0.4 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 [kW] 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 [Mcal/h] Fig. 2 X = Thermal power Y = pressure in combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GM X0 - GM X1 - GM X3 - GM X4 DUAL FUEL GAS/LIGHT-OIL BURNERS AT SINGLE SK073501_A_en STAGE DIMENSIONS [MM] Fig. 3 Dimensions: GM X0 - GM X1 - GM X3 - GM X4 MODEL A B C D E F G H P S R1 R2 R3 R4 RD GM X0 - D1/2" - S 15 162 175 90 43 305 210 65 150 150 133 200 254 240 Rp 1/2 GM X1 - D1/2" - S 15 162 175 90 43 305 210 65 150 150 133 200 254 240 Rp 1/2 GM X3 - D1" - S 16 185 195 108 54 340 248 70 190 150 168 280 337 291 Rp 1 GM X4 - D1" - S 20 185 195 125 78 368 248 70 200 200 173 280 337 319 Rp 1 BOILER PLATE Fig. 4 Boiler plate MODEL L min L* L max M N min N* N max GM X0 mm 130 150 170 M8 100 110 130 GM X1 mm 130 150 170 M8 100 110 130 GM X3 mm 150 170 170 M8 120 130 140 GM X4 mm 170 205 226 M10 130 140 160 *: Suggested dimension of connection between burner and generator. FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** GM X0 mm 90 150 GM X1 mm 90 150 GM X3 mm 130 250 GM X4 mm 160 280 ** For different flame lengths, please contact our Technical-Sales Department. GM X0 - GM X1 - GM X3 - GM X4 DUAL FUEL GAS/LIGHT-OIL BURNERS AT SINGLE SK073501_A_en STAGE PRODUCT SPECIFICATION SHORT DESCRIPTION Dual fuel gas/light-oil burners at single stage. DETAILED SPECIFICATION Dual fuel gas/light-oil burners at single stage, composed by: • Aluminium frame; • Fan at high pressurisation; • Combustion head with adjustment at high performance and elevated flame stability equipped with blast tube and flame disc; • Flange and insulating gasket for fixing at boiler; • Single-phase power supply; • Manual switch for the fuel selection gas/light-oil; • Safety air pressure switch to stop the burner in lock-out in case of failed or anomalous fan operation; • Models GM X0 - GM X1 with gas train with one-block valve class B; • Models GM X3 - GM X4 with gas train with safety valve class A, adjustment 1st stage valve class A; • UV probe for flame detection; • IP 40 electric protection level. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2014/68/EU Directive M.D.; • 97/23/CE Directive P.E.D.; • 2009/142/CE Directive GAS; • Reference rules: EN676 (gas) - EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible pipes; • Line filter; • Isomart gasket; • Nozzle; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise protection; • Antivibration couplings; • Handle gas taps. The illustrations and data here…

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

FBR GM X4 adalah pembakar dual fuel gas/light-oil single stage yang dirancang untuk aplikasi industri berat seperti ketel uap dan tungku pemanas. Dengan rentang daya termal 99,5–199,5 Mcal/h (116–232 kW), konsumsi gas 11,6–23,2 Nm³/h, dan perlindungan IP 40, unit ini cocok untuk sistem yang membutuhkan fleksibilitas bahan bakar dan keandalan tinggi. Dilengkapi katup kerja single stage, katup pengaman, dan pressure switch gas minimum, FBR GM X4 siap diintegrasikan ke berbagai sistem pembakaran industri.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi teknis FBR GM X4?

FBR GM X4 memiliki daya termal 99,5–199,5 Mcal/h (116–232 kW), konsumsi gas 11,6–23,2 Nm³/h, dan konsumsi light-oil 10–20 kg/h. Unit ini beroperasi pada 1/N~230V-50Hz dengan daya listrik nominal 250 W, perlindungan IP 40, dan tingkat kebisingan 67–68 dBA. Berat total 19 kg dengan diameter nozzle 160 mm.

Untuk apa FBR GM X4 digunakan?

FBR GM X4 digunakan sebagai pembakar dual fuel gas/light-oil single stage untuk ketel uap, tungku industri, dan sistem pemanas thermal oil. Cocok untuk aplikasi yang memerlukan peralihan bahan bakar antara gas alam (G20) dan LPG (G31) atau light-oil tanpa mengubah konfigurasi utama.

Apa perbedaan FBR GM X4 dengan model GM X0, GM X1, dan GM X3?

FBR GM X4 memiliki kapasitas tertinggi dalam seri GM X, dengan daya termal 99,5–199,5 Mcal/h (116–232 kW), sedangkan GM X0 hanya 19–29 Mcal/h (22,6–34,3 kW). GM X4 juga menggunakan gas train D1" dengan tekanan minimum gas 18/33 mbar, lebih besar dibanding GM X0 dan GM X1 yang menggunakan D1/2".

Di mana beli FBR GM X4 di Indonesia?

Anda dapat membeli FBR GM X4 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai sehingga produk tiba di lokasi Anda dalam kondisi siap pakai. Hubungi tim kami untuk minta penawaran dan informasi ketersediaan.

Bagaimana cara memilih antara bahan bakar gas dan light-oil pada FBR GM X4?

FBR GM X4 dirancang sebagai dual fuel, artinya dapat beroperasi dengan gas alam (G20), LPG (G31), atau light-oil 1,5°E. Pemilihan bahan bakar dilakukan melalui pengaturan pada panel kontrol dan katup gas train. Pastikan tekanan gas masuk sesuai spesifikasi: minimum 18 mbar untuk gas alam dan 33 mbar untuk LPG pada gas train D1".

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
GM X4 TC | Variant: variant_2 | Subgroup: Burner
FBR
GM X4 TC | Variant: variant_2 | Subgroup: Burner
X GM X1 TL | Variant: variant_2 | Subgroup: Burner
FBR
X GM X1 TL | Variant: variant_2 | Subgroup: Burner
GM X0 TL | Variant: variant_2 | Subgroup: Burner
FBR
GM X0 TL | Variant: variant_2 | Subgroup: Burner
X GM X3 TL | Variant: variant_2 | Subgroup: Burner
FBR
X GM X3 TL | Variant: variant_2 | Subgroup: Burner
X GM X1 TC | Variant: variant_2 | Subgroup: Burner
FBR
X GM X1 TC | Variant: variant_2 | Subgroup: Burner
X GM X0 TC | Variant: variant_2 | Subgroup: Burner
FBR
X GM X0 TC | Variant: variant_2 | Subgroup: Burner

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL