Burners

What Is a Nozzle Pump?

A nozzle pump is a precision fuel-delivery component that atomizes liquid fuel into a fine spray for efficient combustion in industrial burners, furnaces, and heating systems. Unlike a standalone pump, a nozzle pump integrates pump mechanics with spray nozzle geometry to deliver consistent flow rates and droplet size at controlled pressures. 3G Electric supplies authorized distributor inventory of nozzle pumps from Jetoil, CBM, Pratissoli, and Interpamp—brands trusted across Indonesia's manufacturing, petrochemical, and marine sectors for over 35 years.

How Nozzle Pumps Work

Nozzle pumps pressurize fuel oil and force it through precision orifices, breaking the liquid into a fine mist. The spray angle (measured in degrees) determines coverage pattern: full-cone nozzles (60°–80°) distribute fuel evenly across a wide area, while hollow-cone designs concentrate spray at the perimeter. Pressure rating (typically 10–25 bar for industrial units) controls droplet fineness and flow rate. Higher pressure = finer atomization = better combustion efficiency. Operating temperature tolerance prevents seal degradation in hot engine compartments or furnace jackets.

Nozzle Pump Specifications & Comparison Table

Model Flow Rate Spray Angle Type Pressure
[[PRODUCT:JTO36008|Jetoil 0.40 80° H]] 0.40 GPH 80° Hollow-cone 10 bar
[[PRODUCT:FLU05028|CBM Fluidics 0.50 60° SF]] 0.50 GPH 60° Full-cone 10 bar
[[PRODUCT:JTO16054|Jetoil 3.50 80° S]] 3.50 GPH 80° Full-cone 10 bar
[[PRODUCT:FLU05035|CBM Fluidics 45.00 60° SF]] 45.00 GPH 60° Full-cone 10 bar
[[PRODUCT:KF0028-000|Pratissoli PUMP KF28 R]] 28 GPH 60° Full-cone 10 bar
[[PRODUCT:ZROTINKIT-000|Interpump ROTOCLEAN KIT W/ NOZZLE 140]] Modular Configurable Assembly kit 10–15 bar

Selection Criteria for Nozzle Pumps

  1. Flow Rate (GPH): Match the nozzle pump to your burner's fuel consumption. Undersizing starves the combustion chamber; oversizing wastes fuel. For small commercial units (≤100 kW), choose 0.40–3.50 GPH; for industrial furnaces (100–500 kW), use 28–45 GPH.
  2. Spray Angle: Full-cone (60°–80°) suits wide, evenly distributed combustion chambers. Hollow-cone concentrates fuel at the perimeter—ideal for compact, high-intensity burners. Verify your burner's design specs.
  3. Pressure Rating: Most industrial nozzles operate at 10 bar. Some high-efficiency systems require 15–25 bar for finer atomization. Check your pump discharge pressure (bar) before ordering.
  4. Operating Temperature: Fuel inlet temperature in tropical Indonesia may reach 40–50 °C. Confirm the nozzle's maximum rated temperature (typically 60–120 °C) to prevent seal failure.
  5. Fuel Type: Diesel (D2), light fuel oil (HFO), or kerosene. Jetoil and CBM nozzles are rated for standard commercial oils; confirm compatibility with specialty fuels.

Applications in Indonesia

Nozzle pumps are essential in industrial boilers (sugar mills, textile dyeing), marine auxiliary engines, power generation, and building heating systems across Jakarta, Surabaya, Batam, and Medan. Tropical humidity and salt-air environments in coastal regions accelerate corrosion—sourcing stainless-steel nozzles from Jetoil or CBM extends service life. 3G Electric delivers complete import documentation and technical support in English.

FAQ

How do I choose between full-cone and hollow-cone nozzles?
Full-cone nozzles (60°–80° spray angle) distribute fuel evenly across wide combustion chambers; hollow-cone concentrates spray at the perimeter for compact, high-intensity burners. Check your burner's design manual to match spray geometry.
What does GPH mean, and how do I size my nozzle?
GPH (gallons per hour) is fuel flow rate at standard pressure (10 bar). Multiply your burner's thermal output (kW) by 0.12 to estimate GPH; round to the nearest nozzle size. Example: 30 kW burner ≈ 3.6 GPH → select Jetoil 3.50 80° S.
Can I use a nozzle pump in hot climates?
Yes, but verify operating temperature limits. Most Jetoil and CBM units handle 60–120 °C inlet fuel. In Indonesia, fuel temps may reach 45–50 °C during peak sun; margin is safe. Monitor seals annually in coastal salt-air zones.
Where can I buy nozzle pumps in Indonesia?
3G Electric stocks Jetoil, CBM, Pratissoli, and Interpump nozzles with same-day quoting and delivery to Jakarta, Surabaya, and Batam. Contact us for technical sizing and import documentation support.

Why Source from 3G Electric?

3G Electric is an authorized distributor of Jetoil, CBM, Pratissoli, and Interpump, holding 8+ nozzle pump products in stock across Indonesia. With 35+ years of industrial equipment experience, we provide technical sizing assistance, full import documentation, and English-language customer support. Fast turnaround quotes and delivery to Jakarta, Surabaya, Batam, and beyond.

Key Takeaways

  • Nozzle pumps deliver 0.40–45 GPH at 10–15 bar, with spray angles from 60°–80°, for precise fuel atomization in industrial burners.
  • Match flow rate to burner thermal output; verify spray angle geometry and pressure rating against your system's design specs.
  • In tropical Indonesia, confirm operating temperature limits and use corrosion-resistant materials in coastal installations.
  • 3G Electric stocks authorized Jetoil, CBM, Pratissoli, and Interpump nozzles with same-day quotes and Indonesia delivery.

Ready to find the right nozzle pump? Contact 3G Electric today for free technical sizing, competitive pricing, and rapid delivery to your location in Indonesia. Call our Jakarta office or submit an online quote request.

Pertanyaan yang Sering Diajukan
How do I choose between full-cone and hollow-cone nozzles?+
Full-cone nozzles (60°–80° spray angle) distribute fuel evenly across wide combustion chambers; hollow-cone concentrates spray at the perimeter for compact, high-intensity burners. Check your burner's design manual to match spray geometry.
What does GPH mean, and how do I size my nozzle?+
GPH (gallons per hour) is fuel flow rate at standard pressure (10 bar). Multiply your burner's thermal output (kW) by 0.12 to estimate GPH; round to the nearest nozzle size. Example: 30 kW burner ≈ 3.6 GPH → select Jetoil 3.50 80° S.
Can I use a nozzle pump in hot climates?+
Yes, but verify operating temperature limits. Most Jetoil and CBM units handle 60–120 °C inlet fuel. In Indonesia, fuel temps may reach 45–50 °C during peak sun; margin is safe. Monitor seals annually in coastal salt-air zones.
Where can I buy nozzle pumps in Indonesia?+
3G Electric stocks Jetoil, CBM, Pratissoli, and Interpump nozzles with same-day quoting and delivery to Jakarta, Surabaya, and Batam. Contact us for technical sizing and import documentation support.
support_agent
Butuh Bantuan Teknis?
Para engineer kami tersedia untuk konsultasi khusus mengenai rakitan peralatan yang kompleks.
Hubungi Dukungan