The Siemens Cell QRB1B-D042B20B is a photoresistor-based burner control for oil burner flame monitoring in small power burners, supplied with two-wire thermoplastic cable and bracket mounting (21 mm or 36 mm hole…

EXW Singapore
Collect or forward from our office
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Common specifications

Siemens
Shared across the range — Model vary by variant (see table below).
cable type
Two-wire thermoplastic
application
Oil burner flame monitoring for small power burners
sensor type
Photoresistor (flame sensor)
target audience
OEM integration
mounting options
Bracket mounting (with or without soft plastic sleeve)
iso certifications
ISO 9001:2000, ISO 14001:1996
reference document
CC1N7714fr, dated 08.2003
compliance standards
89/336/CEE (EMC Directive)
maintenance cleaning
Clean cloth only (do not use burner sprays)
response sensitivity
Normal or elevated
certification numbers
00739, 38233
compatible control units
LAL..., LOA..., LMO... safety control units
flame detection spectrum
Visible spectrum (yellow oil flame)
cable routing requirement
Separate from other cables, especially ignition cables
signal measurement method
Probe current measurement (microamperes)
bracket hole spacing options
21 mm, 36 mm
maintenance personnel requirement
Qualified personnel only
installation personnel requirement
Qualified personnel only
commissioning personnel requirement
Qualified personnel only
protection against mechanical damage
Not to be returned to service after drop or impact

From the manufacturer's datasheet

Siemens
Sensing Element
Photoresistor (photorésistance)
Flame Type
Yellow flame oil burners
Compatible Safety Controls
LAL..., LOA..., LMO...
Cable Length Options
18/20, 28/30, 33/35, 48/50, 58/60, 68/70, 78/80, 148/150 cm (with/without sleeve
Stripped Cable Length
25, 40, or 70 mm depending on version
Sensitivity Options
Normal (black housing) or high (red housing)
Housing Length
Standard 50 mm or 65 mm
Cable End Termination
Without insulation or with ferrule
Features
  • Small photoresistor flame detector for oil burners
  • Monitors visible spectrum of oil flames
  • Available with or without soft plastic sleeve
  • Mounting via flange, collar, or sleeve
  • Guide groove and cam ensure correct orientation
  • Signal measured via probe current
Typical applications
Monitoring yellow flames in oil burnersUsed with LAL..., LOA..., and LMO... safety controlsFor OEMs integrating QRB... sensors in their products
Do not open, modify, or intervene on the device; disconnect from mains before any work.
After a drop or impact, do not reuse the sensor as safety functions may be impaired even without visible damage.
Select a size

Showing 20 / 20 variants — scroll the table for more

Part No (MPN)—3G SKU3G-CBM-05785ModelQRB1A-A068B70B
Part No (MPN)—3G SKU3G-CBM-05786ModelQRB1B-D042B20B
Part No (MPN)—3G SKU3G-CBM-05787ModelQRB1B-A048B70B
Part No (MPN)—3G SKU3G-CBM-05788ModelQRB1B-C036B40A
Part No (MPN)—3G SKU3G-CBM-05789ModelQRB1B-A068B70B
Part No (MPN)—3G SKU3G-CBM-05790ModelQRB1A-A150B70A
Part No (MPN)—3G SKU3G-CBM-05791ModelQRB3(1)
Part No (MPN)—3G SKU3G-CBM-05792ModelQRC1A1.101C27
Part No (MPN)—3G SKU3G-CBM-05793ModelRAR9
Part No (MPN)—3G SKU3G-CBM-05796ModelQRB4A-B036B40B
Part No (MPN)—3G SKU3G-CBM-05797ModelQRB4B-B036A25
Part No (MPN)—3G SKU3G-CBM-05798ModelQRB4B-B036B40B
Part No (MPN)—3G SKU3G-CBM-05799ModelQRB4B-B050B70
Part No (MPN)—3G SKU3G-CBM-05800ModelQRB4B-B050B70A
Part No (MPN)—3G SKU3G-CBM-05802ModelQRB4B-B025B40B
Part No (MPN)—3G SKU3G-CBM-05803ModelQRB4B-B036B40
Part No (MPN)—3G SKU3G-CBM-05804ModelQRB4A-B036A25
Part No (MPN)—3G SKU3G-CBM-05805ModelQRB4A-B050B70A
Part No (MPN)—3G SKU3G-CBM-05806ModelQRB4A-B070B70B
Part No (MPN)—3G SKU3G-CBM-05807ModelQRI2B2-B180B
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Ask a question

Minta Penawaran

Ajukan pertanyaan

Pertanyaan yang Sering Diajukan

What is the sensing element of the QRB1...B?

It is a photoresistor (photorésistance) that monitors the visible spectrum of oil flames.

What are the available cable lengths?

Available lengths (with/without sleeve) are 18/20, 28/30, 33/35, 48/50, 58/60, 68/70, 78/80, and 148/150 cm.

How is the flame signal measured?

The flame signal is measured by the probe current (μA) generated by the photoresistor under light incidence.

Ulasan pelanggan

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first

Siemens Produk

3G Electric memasok Siemens burner controls. We supply genuine products and their technical documentation.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas →Transformator Pengapian →Kontrol Pembakar →Suku Cadang →Semua Produk →

Lainnya dari Siemens

Lihat semua Siemens suku cadang →
Base for LOA LGB LGA (AGK11)
Siemens
Base for LOA LGB LGA (AGK11)
Base for LAL (AGM41)
Siemens
Base for LAL (AGM41)
Relay LGK 16 335A17 110V
Siemens
Relay LGK 16 335A17 110V
Relay LME 21 230C2
Siemens
Relay LME 21 230C2
Cell QRA 2M
Siemens
Cell QRA 2M
Siemens
Siemens
Mounting for QRB1 (A)
Siemens
Siemens
Flange for QRB1 (A)
Relay LMO 64 301.C2
Siemens
Relay LMO 64 301.C2