Allanson AHVPS-714-06-MV-PCB High Voltage Power Supply

Allanson 3G-OTH-02986 adalah catu daya tegangan tinggi (high voltage power supply) yang dirancang khusus untuk sistem pembersih udara elektrostatik (electrostatic air cleaner). Dengan input universal 120V-240V, unit…

SKU 3G-OTH-02986

Juga terdaftar sebagai: AHVPS71406MVPCB · AHVPS 714 06 MV PCB

Merek
Allanson
Item
AHVPS-714-06-MV-PCB High Voltage Power Supply
Kategori
High Voltage Power Supplies
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Allanson
Dimensions
8"x10"x4"
Input Voltage
120V-240V
Construction Type
PCB
Max Output Current mA
6mA
Max Output Power Wattage
100W
Input Current @ 120V/240V
0.85A/0.42A
Max Output Voltage Ionizer/Collector
14/7KVDC

Konten Lembar Data

[{"filename":"AHVPS714-06-MV-PCB-specs-and-manual-Rev-6-June-27-2022.pdf","text":"Rev. 5 June 27/2022\n\n 14kV / 6mA High Voltage Power Supply for Electrostatic\n Air Cleaner\n\n Specifications and operating manual\n\n Cat # AHVPS714-06-MV-PCB\n\n 1. Overview\n\nThe 14kVDC/6mA HV power supply is an OEM product and comes without AC\npower ON/OFF switch and safety interlocks. It is system integrator responsibility\nto assure that all national, state and local electrical safety codes are followed.\n\n 1.1 Principle of operation\n\nThe block diagram of HV Power Supply is shown in Fig. 1\n\nThe HV Power supply has built in universal input, power factor corrected AC/DC power\nconverter, which produces 450VDC for the resonant DC/DC HV power converter. The\nResonant Power Converter drives the HV step up transformer, which delivers up to\n1.5kV RMS to the HV multiplier. The 4 stage HV multiplier produces up to 14kVDC at\nthe output (Ionizer) and 7kVDC at the output of second stage (collector).\n\nThis PS has capabilities to deliver up to 6mA DC current at 14KVDC to 2 X 24” Linear\ncells. Max input current on 120V is 0.85A\n\nThe resonant power converter is over voltage, over current, overpower protected\nincluding continuous output short circuit condition.\n\nOperating HV and output current limit are set manually however Intelligent Controller\nhas the capability to perform the following functions:\n\n 1. Monitors HV and output current\n\n 2. Maintain the best performance and minimize load cell arcing\n\n 3. Reports HV converter status using LED Lamps and optional serial messages on\n RS-485 port or Modbus.\n Operating HV, Current, number of hours of operation, error codes can be\n monitored on optional RS-485 output or Modus output terminals.\n 1 Rev. 6\n 06/27/2022\n\f Additional HV and current can be monitored on scaled down analog output.\n\n I Monitor – 100mV per 1mA\n\n V monitor – 100mV per 1KV\n\n 4. Keeps track of operating hours\n\n 5. Connect to Remote LED diagnostic PCB.\n\nStatus LED functionality and simplified flowchart are shown in Appendix A.\n\n\n\n Universal Input\n 120 - 240 VAC\n\n N L GND\n\n\n\n J30\n HV POWER FACTOR\n REMOTE J17 CORRECTOR POWER TRANSFORMER\n ON/OFF MODULE\n\n Remote\n LED J6\n Panel 14kV\n J1 7kV\n HV HV MULTIPLIER\n GOOD\n RELAY\n POWER\n CONVERTER\n &\n CURRENT\n RV3 CONTROLLER\n LIMIT\n ADJUST\n\n HIGH\n VOLTAGE RV4\n ADJUST\n\n\n V MONITOR J13 CURRENT FEEDBACK\n\n VOLTAGE FEEDBACK\n I MONITOR\n\n\n\n\n INTELLIGENT\n CONTROLLER\n\n J2 J12\n\n\n BURN IN RS-485\n\n\n\n\nFig.1 HV Power Supply Block Diagram\n 2 Rev. 6\n 06/27/2022\n\f2.0 Modes of operation\n\nStandby Mode (HV converter is OFF, Microcontroller – MCU is ON)\nHV Converter ON Mode\n Voltage Source Mode\n Current Source Mode\n Burn-in Mode\n\n\n2.1 Standby Mode\n\n2.2 In Standby Mode the main supply is On (J30) and powers microcontroller (MCU)\n circuit. The MCU reports the power supply status on serial port. J12 open (Run\n signal is not received) -- Standby Mode\n\n\n\n2.2 HV Converter ON Mode\n\n\nVoltage source Mode\n\nIn Voltage Source Mode the HVPS maintains the preset voltage while current is\ndetermined by the load. If current does not exceed the max limit of 6mA the HVPS will\nmaintain the preset HV.\nVoltage mode example settings: The HV was set to 12kV and current limit was set to\nthe maximum value of 6mA. After connecting the clean load cell, the HVPS was\noperating at 12kV with current floating around 6mA. With the same settings and dirty\nload cell connected, the HVPS was still operating at 12kV, but the load current dropped\nto 5mA.\n\nCurrent Source Mode\n\nIn Current Source Mode the HVPS maintains the preset current while voltage is\ndetermined by the load. If output voltage does not exceed the max limit of 14kV the\nHVPS will maintain the preset current.\nCurrent Mode example settings. The current limit was set to 6mA and HV to 14kV. After\nconnecting the clean load cell, the HVPS was operating at 6mA current and HV floating\naround 12kV. With the same settings and dirty load cell connected, the HVPS\nwas operating with 6mA current, but HV increased to 12.5kV to maintain 6mA current.\n\n\n\n 3 Rev. 6\n 06/27/2022\n\fBurn-In Mode.\n\nThe Burn-in Mode is invoked by the pushbutton momentary switch SW1 located on the\nPCB or by shorting terminals of connector J2 located next to the pushbutton switch or\nterminating two wires to external momentary push button.\n\nIn normal operation the HVPS is exposed to occasional overload conditions caused by\narcing in the load cells. The HVPS monitors the rate and duration of overload conditions\nand shut down if overload condition persists.\n\nNew load cells may be contaminated with remnants of machining process and may\ncause excessively high rate of arcing for first few hours of operation which may cause\nthe HVPS to shut down prematurely. To prevent this unnecessary shutdown the Burn In\nmode was introduced.\n\nWhen Burn In mode is activated (by pressing the Burn In ON/OFF switch), red LED will\nbe blinking until burning process is completed or terminated, the HVPS will not shut\ndown in response to persistent overload condition for 3 hours period.\nIn Burn-In mode the protection algorithm, which monitors rate and duration of overloads\nand shuts down the HVPS if overload persists is suspended for 3 hours.\nThe Burn In mode can be terminated before 3-hour timer expires by pressing the Burn\nIn ON/OFF switch.\nDuring Burn In cycle the display alternates between standard Voltage and Current\nreadings\nand Burn In cycle message.\n\n\n 3.0 Installation and safety\n\n The HV Power Supply must be mounted indoors, protected from weather\n\nElements, in a location easily accessible by operating service personnel.\n\nThe HV Power Supply is equipped with universal input; power factor corrected (PFC)\nAC/DC power supply and can operate from 120VAC or 240VAC power lines.\nThe maximum current draw is 0.85 Amp from 120 VAC line and 0.42 Amp from 240VAC\nline. Use these numbers to select proper wire gage as per applicable standards.\n\nThe connection diagram of HV Power Supply is shown in Fig.2 All connections are\nmade to terminals on the Main Board.\n\nThe HV Multiplier has two outputs:\n\nIonizing Voltage – Labeled as 14kVDC\n\n 4 Rev. 6\n 06/27/2022\n\fCollector Voltage – Labeled as 7kVDC\n\nThe HV and current adjustment trim pots, Dry Contact (J17) terminal block, AC power\ninput (J30), HV Good Relay (J1) and RS-485 serial port (J12) are located at the outside\npart of the Main Board.\nStatus LEDs are placed on the remote panel connected to RJ45 type connector (J6).\n\n\n\n\n 4.0 Field wiring connections\n\n\nThese instructions are for qualified personnel only. To reduce the risk of electric\nshock, do not perform any servicing other than contained in the instructions\nunless you are qualified to do so. All wiring must be installed according to\nnational, state and local codes.\n\nThe HV Power Supply requires the following field connections shown in Fig.2\n\n 1. AC line connection (main input) including safety GND (J3, highlighted in green)\n 2. HV Connection to cells (7kV and 14kV terminal studs, highlighted in red)\n 3. HV Relay status contacts (J1, highlighted in green)\n 4. RS-485 / Modbus communication port (J12, highlighted in green)\n 5. HV GND from the cells to be connected to ground terminal on the enclosure which\n is connected to the aluminum plate and PCB board ( AC GND connection point) -\n connection point is located at the PCB corner which provide connection to\n mounting chassis by mounting screw.\n 6. Remote start ON/OFF terminals J17 highlighted in green (To turn HV converter\n ON - dry contact closure is needed)\n 7. Remote diagnostic LED panel connected to RJ45 type connector J6 on the Main\n Board (highlighted in green)\n 8. Remote momentary push button located on front face of enclosure (burn in\n function ) connected via two wires to J2 (highlighted in green)\n 9. Optional Voltage and current Monitor (J13)\n\n\n\n\n 5 Rev. 6\n 06/27/2022\n\f Air cleaner 14 kV HV power supply\n Connections, indicators and controls\n\n\n\n HV\n 2\n GOOD\n 1 J1\n RELAY\n RESONANT\n POWER HV TRANSFORMER\n CONVERTER\n\n LED\nPANEL J6\n\n RV3\n\n\n Min. Max.\n HV ADJUST HV ON\n RV5 HV GND\n\n\n Min. Max.\n CURRENT\n LIMIT\n ADJUST\n HV MULTIPLIER\n 7 kV\n POWER ON\n\n\n FAULT 14 kV\n\n HV\n GOOD INTELLIGENT\n CONTROLLER PFC AC/DC\n V MONITOR 1 J 13 POWER\n 2 J 30\n GND 3 J 16 SUPPLY\n I MONITOR 4 GND 3\n 2\n 1 J 12\n 3 NEUTRAL 2\n GND 2\n A B J 17\n 1 2\n 1 LINE 1\n BURN IN\n SWITCH HV AC\n RS-485 REMOTE INPUT\n PORT ON/OFF\n\n\n\n\nFig.2 Connections, Indicators and Controls\n\n\n\n…

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Allanson Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Allanson 3G-OTH-02986 adalah catu daya tegangan tinggi (high voltage power supply) yang dirancang khusus untuk sistem pembersih udara elektrostatik (electrostatic air cleaner). Dengan input universal 120V-240V, unit ini menghasilkan output maksimum 14/7KVDC (Ionizer/Collector) dan arus output 6mA, serta daya maksimum 100W. Konstruksi PCB-nya berukuran 8"x10"x4", menjadikannya solusi OEM yang ringkas untuk integrator sistem yang membutuhkan suplai tegangan tinggi andal untuk aplikasi pengendalian polusi udara industri.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa Allanson AHVPS-714-06-MV-PCB digunakan?

Allanson AHVPS-714-06-MV-PCB adalah catu daya tegangan tinggi yang digunakan sebagai komponen OEM dalam pembersih udara elektrostatik (electrostatic air cleaner). Unit ini menyuplai tegangan output 14/7KVDC (Ionizer/Collector) dengan arus maksimum 6mA untuk mengionisasi partikel udara dan mengumpulkannya pada kolektor, sehingga efektif untuk aplikasi pengendalian polusi udara di lingkungan industri.

Apa spesifikasi teknis Allanson AHVPS-714-06-MV-PCB?

Spesifikasi teknis Allanson AHVPS-714-06-MV-PCB meliputi: input tegangan universal 120V-240V, input arus 0.85A pada 120V dan 0.42A pada 240V, output tegangan maksimum 14/7KVDC (Ionizer/Collector), arus output maksimum 6mA, daya output maksimum 100W, dan dimensi 8"x10"x4" dengan konstruksi PCB. Unit ini dilengkapi perlindungan over voltage, over current, overpower, dan hubung singkat output kontinu.

Bagaimana cara memilih Allanson AHVPS-714-06-MV-PCB yang tepat?

Pemilihan Allanson AHVPS-714-06-MV-PCB yang tepat bergantung pada kebutuhan sistem pembersih udara elektrostatik Anda. Pastikan tegangan input (120V-240V) sesuai dengan suplai listrik di lokasi, dan periksa kebutuhan output tegangan (14/7KVDC) serta arus (6mA) agar sesuai dengan beban sel linear yang digunakan. Unit ini dirancang untuk 2 x 24" sel linear, jadi pastikan konfigurasi sel Anda kompatibel.

Di mana beli Allanson AHVPS-714-06-MV-PCB di Indonesia?

Anda dapat membeli Allanson AHVPS-714-06-MV-PCB melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai sehingga Anda dapat menerima produk dengan mudah. Hubungi kami untuk minta penawaran dan informasi lebih lanjut mengenai ketersediaan produk ini.

Apakah Allanson AHVPS-714-06-MV-PCB memiliki perlindungan keamanan?

Ya, Allanson AHVPS-714-06-MV-PCB dilengkapi perlindungan over voltage, over current, overpower, dan kondisi hubung singkat output kontinu. Konverter daya resonan dirancang untuk melindungi sistem dari kerusakan akibat gangguan listrik. Namun, sebagai produk OEM, unit ini tidak dilengkapi sakelar ON/OFF dan interlock keselamatan; integrator sistem bertanggung jawab mematuhi kode keselamatan listrik nasional, negara bagian, dan lokal.

Digunakan dalam

Aplikasi umum untuk Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Produk

3G Electric memasok Allanson high voltage power supplies. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson GTO-C-18 High Voltage Cable
Allanson
Allanson GTO-C-18 High Voltage Cable
Allanson GTO-C-42 High Voltage Cable
Allanson
Allanson GTO-C-42 High Voltage Cable
Beckett: Allanson Transformer CAT 1092 TYPE F
Allanson
Beckett: Allanson Transformer CAT 1092 TYPE F
Allanson
Allanson
Allanson UVB264T6-2100-MV-PCB UVB248T6-2100-MV-PCB UV Ballast – Program Start
Allanson
Allanson
Allanson UVB248T6-2200-MV-PCB UV Ballast – Program Start
Allanson
Allanson
Allanson 2742-500 Ignition Transformer

Lainnya dari Allanson

Lihat semua Allanson suku cadang
Allanson
Allanson
Allanson AHVPS-714-40-MV High Voltage Power Supply
Allanson
Allanson
Allanson AHVPS-714-12-MV-PCB High Voltage Power Supply
Allanson
Allanson
Allanson AHVPS-714-40-MV-PCB High Voltage Power Supply
Allanson
Allanson
Allanson AHVPS-48-1-MV High Voltage Power Supply