Allanson AHVPS-714-40-MV High Voltage Power Supply

Allanson 3G-OTH-02988 adalah High Voltage Power Supply yang dirancang khusus untuk sistem pembersih udara elektrostatik (electrostatic air cleaner). Catu daya bertegangan tinggi ini memiliki input voltage 120V-240V…

SKU 3G-OTH-02988

Juga terdaftar sebagai: AHVPS71440MV · AHVPS 714 40 MV

Merek
Allanson
Item
AHVPS-714-40-MV High Voltage Power Supply
Kategori
High Voltage Power Supplies
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Allanson
Dimensions
12"x15"x6"
Input Voltage
120V-240V
Construction Type
Nema 4 Enclosure
Max Output Current mA
40mA
Max Output Power Wattage
500W
Input Current @ 120V/240V
4A/2A
Max Output Voltage Ionizer/Collector
14/7KVDC

Konten Lembar Data

[{"filename":"3G-OTH-02988-High-Voltage-Power-Supply-Spec-Manual-v5.pdf","text":"3G-OTH-02988\n 14kV/40mA High Voltage Power Supply for Electrostatic Air Cleaner\n Specifications and Operating Manual\n\n\n\n 1. General\n The HV Power Supply must be mounted indoors, protected from weather\nElements, in a location easily accessible by operating service personnel.\n\nThe HV Power Supply is equipped with universal input; power factor corrected (PFC) AC/DC power\nsupply and can operate from 120VAC or 220VAC power lines.\nThe maximum current draw is 6 Amp from 120 VAC line and 3Amp from 220VAC line.\nUse these numbers to select proper wire gage as per applicable standards.\n\nThe block diagram of HV Power Supply is shown in Fig.1.\nIt comprises 4 assemblies:\n\n • Control/Power Board\n • HV Transformer\n • HV Multiplier\n • Display Module\n\n\n The PFC AC/DC Power Supply produces 450V DC, which powers the Resonant Power Converter.\nThe Resonant Power Converter drives the step up Power Transformer, which center tap output winding\nsupplies up to 1.5KV RMS to the HV Multiplier. The HV Multiplier has two outputs:\n\nIonizing Voltage – Labeled as 14kV\nCollector Voltage – Labeled as 7kV\n\nThe Display Module monitors and displays crucial operating parameters and error codes and controls\nstatus LEDs. The HV adjust potentiometer is located below display panel.\n\n\n\n\n 1\n\f AIR CLEANER HV POWER SUPPLY\n WIRING\n\n\n\n 4 N2 4\n RESONANT 3 3\n J6 2 2\n POWER 1 1\n CONVERTER N1\n N3 HV TRANSFORMER\n 2 2\n J7 1 1\n\n 2 FAST CLAMP 2\n J8 1 1\n\n\n 10\n DIRTY CELL 9\n 8 CONTROL / POWER BOARD\n FAULT\n 7\n 6\n HV ON\n 5 J2\n 4\n POWER ON\n 3 I MON HV GND\n 2 1 1\n REMOTE INTERLOCK J9 2 2\n 1\n\n 1 V MON 1\n J10 2 2\n ENCLOSURE\n INTERLOCK\n J1 HV MULTIPLIER\n PFC AC/DC\n POWER 7 kV\n SUPPLY\n AC LINE 3\n INPUT NEUTRAL 2\n J3\n J3\n GND 1 14 kV\n\n\n\n\n DISPLAY\n\n\n\n\n Min. Max.\n HV ADJUST\n\n\n\nFig.1 HV Supply wiring diagram\n\n\n\n\n 2\n\f 2. Field wiring connections\n\nWARNING - RISK OF ELECTRIC SHOCK\n\nThese instructions are for qualified personnel only. To reduce the risk of electric shock, do not perform\nany servicing other than contained in the instructions unless you are qualified to do so. All wiring must\nbe installed according to national, state and local codes.\n\nDO NOT MODIFY ENCLOSURE.\n\nModifications of this enclosure would void warranty. Pre-punched knockouts have been provided for\nconduit attachment.\n\n\nFOR INDOOR USE ONLY.\n\nThis is NEMA 1 rated enclosure intended for indoor use only to provide degree of protection against contact with\nenclosed power supply.\n\n\n\nThe HV Power Supply requires the following field connections:\n\n\n 1. AC line connection (J3, highlighted in green)\n 2. HV Connection (7kV and 14kV terminal studs, highlighted in red)\n 3. Monitoring/ Diagnostic connection (J2, highlighted in green)\n\nThe Monitoring/Diagnostic connections are optional and HV Power Supply will operate normally if they\nare not connected.\n\n 2.1 AC line connections\n\nAll primary wiring should be permanently installed in conduit. Under no circumstances should\nextension cords be used to connect the source of the electrical supply to the equipment.\nHV Power Supply unit must be grounded to structural steel or earth ground.\n\n - Remove ~ 100mm of conduit and strip off 10mm of wire insulation\n - Put the AC line conduit through the knockout Labeled AC In.\n - Install the 3 pin plug and connect Line, Neutral and GND wires as shown in Fig.1\n - Plug the 3 pin plug to terminal header J3\n - Secure the conduit entry.\n\n\n\n 3\n\f 2.2 HV Connections\n\nHigh voltage cable is supplied to connect the ionizer and collector sections of the electrostatic\nCells to the ionizer and collector terminals in the power supply. The red cable is used for the ionizer, and\nthe blue cable is used for the collector.\n\nThe high voltage cables should be installed in separate metallic\nconduits, such as EMT or rigid conduit. Under no circumstances should the high voltage cable be\nspliced or terminated at locations other than the power supply\nor electrostatic collectors.\n\nKnockouts for the conduits that carry the high voltage cables are located on the top and side of the\npower pack. The ends of the high voltage cable should not be terminated until the\nconduit is installed and the cable is pulled. Terminate the cables at the power pack by stripping off 3/8”\nof insulation and installing a ring terminal. Securely attach the red cable\nto the Ionizer “14kV” stud on the HV Multiplier Module, and the blue\ncable to the Collector “7kV” stud.\n\n 2.3 Monitoring/ Diagnostic connections\n\n\n - Remove ~ 150mm of conduit and strip off 10mm of insulation\n - Put the conduit through the knockout Labeled “Status Monitor”\n - Install the 10 pin plug and connect all monitoring lines as shown in Fig.1\n - Plug the 10 pin plug to terminal header J2\n - Secure the conduit entry\n\nIf Monitoring/Diagnostic connections are not used install jumper shorting terminals 1, 2 (Remote\nInterlock) these terminals must be closed to power up the unit.\n\n\n\n\n 2.4 MODBUS Communication port RS-485\nThe HV power supply has a RS-485 communication port Modbus for remote control, set up, and\ndiagnostic.\n\n\n 3. Start - up\n\nRemote Interlock, Enclosure Interlock and Power On/Off switch must be closed for\nthe HV Power Supply to turn On.\nCheck load cells specifications and number of cells connected before adjusting the HV.\n 4\n\f 1. Close the enclosure cover and make sure that locking screw is fully engaged otherwise enclosure\n interlock contacts may not be closed.\n 2. Turn the HV Adjust potentiometer to the minimum (fully CCW position)\n 3. Turn Power switch On. Power On Green LED and HV On Blue LED should turn On. Fault and Dirty\n Cell LEDs should stay Off. If Fault LED comes on follow instruction in Service/troubleshooting\n manual.\n 4. Adjust slowly HV by turning the potentiometer clockwise until output current reaches required\n level.\n\nOutput current adjustment is based on the type and number of load cells connected to the HV supply.\nTypical settings are 1mA per cubic foot of load cell.\nFor example: if 10 3 cubic feet load cells are connected to the power supply the total load is 30 cubic\nfeet and the HV should be set to provide 30mA current to the load.\nCheck load cells specifications and number of cells connected before adjusting the HV.\n\n\n\n\nPlease refer also to Owner Manual of the Electrostatic Kitchen Exhaust\nair Pollution Control System.\n\n\n\n\n 5"}]

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Allanson Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Allanson 3G-OTH-02988 adalah High Voltage Power Supply yang dirancang khusus untuk sistem pembersih udara elektrostatik (electrostatic air cleaner). Catu daya bertegangan tinggi ini memiliki input voltage 120V-240V dengan daya output maksimum 500W dan arus output maksimum 40mA. Dilengkapi dengan Nema 4 Enclosure, unit ini menghasilkan tegangan ionizer 14KVDC dan tegangan collector 7KVDC, menjadikannya pilihan andal untuk aplikasi pengendalian udara di lingkungan industri.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi Allanson AHVPS-714-40-MV?

Allanson AHVPS-714-40-MV berfungsi sebagai catu daya tegangan tinggi untuk electrostatic air cleaner. Unit ini menyuplai tegangan ionizer 14KVDC dan tegangan collector 7KVDC dengan arus output maksimum 40mA, sehingga mampu mengionisasi partikel udara dan mengumpulkannya pada pelat collector untuk membersihkan udara.

Apa spesifikasi input dan output Allanson AHVPS-714-40-MV?

Spesifikasi input: tegangan 120V-240V dengan arus input 4A pada 120V dan 2A pada 240V. Spesifikasi output: tegangan ionizer 14KVDC, tegangan collector 7KVDC, arus output maksimum 40mA, dan daya output maksimum 500W. Unit ini dilengkapi Nema 4 Enclosure dengan dimensi 12"x15"x6".

Di mana beli Allanson AHVPS-714-40-MV di Indonesia?

Anda dapat membeli Allanson AHVPS-714-40-MV melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan kepabeanan untuk memastikan produk sampai ke lokasi Anda dengan aman. Hubungi kami untuk minta penawaran.

Bagaimana cara memasang Allanson AHVPS-714-40-MV?

Pemasangan harus dilakukan oleh personel berkualifikasi. Unit harus dipasang di dalam ruangan, terlindung dari cuaca, dan mudah diakses. Pastikan kabel sesuai dengan arus input maksimum 6A pada 120VAC atau 3A pada 220VAC. Ikuti diagram pengkabelan pada manual untuk menghubungkan remote interlock, enclosure interlock, dan output tegangan tinggi.

Apa kelebihan Allanson AHVPS-714-40-MV dibanding power supply lain?

Allanson AHVPS-714-40-MV memiliki universal input dengan power factor corrected (PFC) AC/DC power supply yang dapat beroperasi pada 120VAC atau 220VAC. Dilengkapi Nema 4 Enclosure untuk perlindungan debu dan air, serta display module yang memonitor parameter operasi dan kode error. Tegangan output ionizer 14KVDC dan collector 7KVDC dirancang khusus untuk electrostatic air cleaner.

Digunakan dalam

Aplikasi umum untuk Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Produk

3G Electric memasok Allanson high voltage power supplies. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson GTO-C-42 High Voltage Cable
Allanson
Allanson GTO-C-42 High Voltage Cable
Allanson GTO-C-18 High Voltage Cable
Allanson
Allanson GTO-C-18 High Voltage Cable
Allanson
Allanson
Allanson 2742-500 Ignition Transformer
Beckett: Allanson Transformer CAT 1092 TYPE F
Allanson
Beckett: Allanson Transformer CAT 1092 TYPE F
Beckett: Allanson Transformer T92 (120v)
Allanson
Beckett: Allanson Transformer T92 (120v)
Allanson 2744-252A Ferromagnetic Ignition Transformer
Allanson
Allanson 2744-252A Ferromagnetic Ignition Transformer

Lainnya dari Allanson

Lihat semua Allanson suku cadang
Allanson
Allanson
Allanson AHVPS-714-12-MV-PCB High Voltage Power Supply
Allanson
Allanson
Allanson AHVPS-714-40-MV-PCB High Voltage Power Supply
Allanson
Allanson
Allanson AHVPS-48-1-MV High Voltage Power Supply
Allanson
Allanson
Allanson AHVPS-714-06-MV-PCB High Voltage Power Supply