Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Supco Thermometer probe and infrared - HVAC Equipment
SupcoHVAC Equipment

Supco Thermometer probe and infrared

Supco EM90 adalah thermometer inframerah dan termokopel dua-dalam-satu yang dirancang untuk pengukuran suhu presisi pada peralatan HVAC dan sistem pembakaran industri. Alat ini menggabungkan sensor inframerah…

SKU 3G-CBM-01291

Juga terdaftar sebagai: COP 14016 · COP-14016

Merek
Supco
Item
Thermometer probe and infrared
Kategori
HVAC Equipment
UNSPSC
40101709 — Air handling unit
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Supco
type
Infrared thermometer with thermocouple meter
thermocouple
K-type
storage humidity
0 to 80% RH
storage temp range
-10°C to 60°C

Konten Lembar Data

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER Users Manual -1- ■.Introduction Thank you for purchasing the SUPCO infrared (IR) thermometer and thermocouple meter. Please take a few minutes to browse through this user manual before you begin to operate the meter to ensure that you are fully familiarized with how best to operate the meter as accurately and safely as possible. This meter combines two precision thermometers in one unit: a noncontact infra-red thermometer and a thermocouple thermometer. This meter can match standard type K-type thermocouple sensor. WARNING! Do not point laser directly at eye or reflective surfaces. 1.1 Precautions safety measures To get the best performance from this meter, please read this user's manual carefully and observe the detailed safety precautions. -2- 1.1.1 During use 1. After abrupt ambient temperature changes, allow instrument temperature to stabilize for 30 minutes before taking measurements. 2. Do not expose thermometer to excessive ambient temperatures. 3. Keep the thermometer clean. 1.1.2 Maintaining the product l Do not measure in a high temperature, high humidity locations. l When not using the instrument for a long time, please remove the battery and avoid storing in high temperature and high humidity. ■ Features 1. Display: 4 digit LCD Display 2. Resolution: 0.1℉/ 0.1℃ 1℉/ 1℃(thermocouple above 1000℃) -3- 3. Range: Infra-red: -58℉ to 572℉ (-50℃ to 300℃) Thermocouple: -328 ℉ to 2372 ℉ (-200 ℃ to 1300℃) 4. Accuracy: Infra-red: ± 5% for -58℉ to -4℉ (-50℃ to -20℃) ± (1.5% reading + 4 ℉ / 2℃) for -4℉ to 572℉ (-20℃ to 300℃) Thermocouple: ±(0.2%reading+2℉/1℃) for -328℉to -148℉(-200℃ to -100℃) ±(0.1% reading +0.7℃/1.4℉) for -148℉ to 2372℉(-100℃ to 1300℃) 5. Emissivity: 0.95 6. Field of view: 2:1 7. Laser power: Less than 1 mw 8. Response time: 0.5 second 9. Auto power off: 25 seconds (infrared) or 20 minutes (thermocouple) 10. Low battery indicator -4- 11. Operating environment: 32℉ to 122℉ (0℃ to 50℃); 0 to 90% RH 12. Storage environment: 14℉ to 140℉ (-10℃ to 60℃,0 to 80% RH 13. Dimensions: 4.76”(L) x 2.36”(W) x 1.18”(H) 121mm(L) x 60mm(W) x 30mm(H) 14. Weight: 6.35 oz (app.) 180 g (app.) 15. Accessories: K-type thermocouple wire (1) Lanyard (1) AAA Batteries (3). Users manual -5- ■Instrument Description 1. Sensor cover 2. Infra-red sensor 3. Thermocouple jack 4. LCD display UNIT MODE 5. Function key LASER TYPE ON/OFF SCAN /H Infrared temperature thermocouple meter l LCD Display -6- Symbol Designations: 1. Indicates Data Hold 2. Indicates the type of thermocouple 3. Indicates IR measurement 4. Emissivity 5. Measurement Display area 6. Measurement Display area 7. Average/ Maximum / minimum Indicator 8. Indicates laser pointer use 9. Indication back light ON 10.Temperature units 11.Low battery indicator ■ Operating instructions TYPE 1. Press the ON/OFF key to turn the unit on. Press the key again to shift the measurement mode between infrared or thermocouple. 2. While in Infra-red mode, press the LASER key to make IR measurements. Point the laser at the target -7- object and press the SCAN/H key for continuous temperature measurements. 3. In the thermocouple mode, press the SCAN/H key for data hold. Press the SCAN/H key again to return the measurement mode. ■ Function Keys 1. TYPE/ON/OFF Key ON/OFF: Press this key to turn the power ON and press the key again for more than 2 seconds to turn the power OFF. TYPE: Press this key to select infra-red or thermocouple mode. 2. key Turns back light on or off. 2. UNIT key Press this key to select temperature units (℉ or ℃) -8- 3. MODE key Press this key to select AVG, MAX or MIN mode. 4. LASER key Turns the laser on/ off for IR measurements. 5. SCAN/H key While in infra-red mode , press this key to take measurements. While in thermocouple mode,Press this key for Data Hold, a icon will be displayed on the LCD. Press the key once more to cancel the hold function. 7. Auto power off setting The instrument is factory set for Auto Power Off. The meter will power itself off after 25 seconds (IR) or 20 minutes (thermocouple) if no key is pressed. To cancel the auto power off function: press the LASER key whith power on until the LCD displays all icons and the back light is on. -9- ■ Emissivity and Field of View Emissivity: Emissivity is a term used to describe the energy emitting characteristics of a material. The higher the emissivity value a material has, the more infrared energy it will emit at a particular temperature. Most organic materials range in emissivity between 0.85 and 0.98. This thermometer has a fixed (non-adjustable) emissivity of 0.95. Measuring objects with an emissivity of less than 0.95 will result in a lower than actual temperature reading on the display. Be aware of this characteristic when measuring low emissivity objects (e.g. shiny, reflective metal objects). An effective solution is that using the black adhesive tape to cover the object surface, taking the measurement when the adhesive tape’s temperature is the same as the object. Field of View: The distance to spot ratio for this thermometer is 2:1. The ideal working range of the noncontact thermometer is between 25mm and - 10 - 250mm(1 and 10 inches). The field of view is a circular measurement area approximately equal to the distance from the target to the unit, divided by 2. To ensure accurate measurements, the measurement target must fill or exceed the field of view. ■Maintenance 1. CLEANING INSTRUCTIONS The meter may be wiped down with a wet sponge or cloth using a mild, water based detergent. NOTE: This unit is not designed for complete submersion or washing in water. 2. BATTERY REPLACEMENT Use the following procedure: When the battery voltage drops below proper operation range the symbol will appear on - 11 - the LCD display and the battery needs to be replaced. ∞ Press the battery cover towards the arrowhead to open the battery cover. ∞ Replace the battery with three new AAA (1.5V) batteries. ∞ Replace the battery cover. WARRANTY Sealed Unit Parts Co., Inc. warrants that it will repair or furnish without charge a similar product to replace any product which, within the specified warranty term after the date of sale by the Wholesaler, is proved to the satisfaction of Sealed Unit Parts Co., Inc. , to have been defective at the time it was sold. Said warranty is in effect only when said item is used in accordance with the instructions and recommendations of Sealed Unit Parts Co., Inc. - 12 - This warranty applies only to products which after shipment from the factory, have not been altered, changed, repaired, or treated in any manner whatsoever. This warranty to repair or replace is the only warranty either expressed, implied or statutory and is the only warranty being issued herein; Sealed Unit Parts Co., Inc.'s liability in connection with its products is expressly limited to the repair or replacement of defective parts. All other damages and warranties, statutory or otherwise, are being expressly excluded. No representative of Sealed Unit Parts Co., Inc. has authority to change this warranty in any manner whatsoever. No attempt to repair or promise to repair or improve any part covered by this warranty by any representative of this company shall be effective unless signed by a properly authorized officer of Sealed Unit Parts Co., Inc. - 13 -
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Supco Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Supco EM90 adalah thermometer inframerah dan termokopel dua-dalam-satu yang dirancang untuk pengukuran suhu presisi pada peralatan HVAC dan sistem pembakaran industri. Alat ini menggabungkan sensor inframerah non-kontak dengan rentang -50°C hingga 300°C dan input termokopel tipe-K yang mampu membaca hingga 1300°C, menjadikannya solusi serbaguna untuk teknisi di lapangan. Dengan resolusi 0,1°C, akurasi ±1,5% pembacaan, dan emisivitas tetap 0,95, Supco EM90 cocok untuk inspeksi cepat pada ketel uap, saluran udara, dan komponen pembakar industri tanpa perlu kontak langsung.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi utama Supco EM90?

Supco EM90 berfungsi sebagai thermometer inframerah untuk mengukur suhu permukaan tanpa kontak (rentang -50°C hingga 300°C) dan sebagai meter termokopel tipe-K untuk pengukuran suhu kontak hingga 1300°C. Alat ini biasa digunakan untuk troubleshooting pada sistem HVAC, boiler, dan pembakar industri.

Apa spesifikasi teknis Supco EM90?

Spesifikasi Supco EM90 meliputi: rentang inframerah -50°C hingga 300°C, termokopel tipe-K -200°C hingga 1300°C, resolusi 0,1°C, akurasi inframerah ±1,5% pembacaan + 2°C, emisivitas 0,95, field of view 2:1, response time 0,5 detik, dan penyimpanan pada suhu -10°C hingga 60°C dengan kelembaban 0-80% RH.

Di mana beli Supco EM90 di Indonesia?

Anda dapat membeli Supco EM90 melalui 3G Electric, distributor resmi yang memasok peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk pengiriman ke berbagai wilayah di Indonesia. Hubungi tim kami untuk informasi ketersediaan dan minta penawaran.

Bagaimana cara menggunakan Supco EM90 untuk mengukur suhu pembakar industri?

Untuk mengukur suhu permukaan pembakar industri, arahkan sensor inframerah Supco EM90 ke target dari jarak aman dengan rasio field of view 2:1. Pastikan emisivitas diatur 0,95. Untuk pengukuran suhu gas buang atau fluida, gunakan probe termokopel tipe-K yang terpisah. Alat akan mati otomatis setelah 25 detik pada mode inframerah.

Apa perbedaan mode inframerah dan termokopel pada Supco EM90?

Mode inframerah pada Supco EM90 mengukur suhu permukaan tanpa kontak hingga 300°C dengan response time 0,5 detik, cocok untuk objek bergerak atau bertegangan tinggi. Mode termokopel tipe-K mengukur suhu kontak hingga 1300°C, ideal untuk pipa, cerobong, atau cairan. Keduanya memiliki akurasi tinggi: ±1,5% untuk inframerah dan ±0,1% untuk termokopel.

Digunakan dalam

Aplikasi umum untuk Supco
Commercial refrigeration display cases — Supco RO82 relay and CSS-25U starter for compressor motor control without run capacitors
Medium-load HVAC systems — Supco SPP 6/SPP 8 hard-start devices to reduce compressor inrush current and extend motor lifespan
Cold-chain pharmaceutical and food storage — SL300TH temperature–humidity data logger for continuous monitoring and regulatory documentation
Refrigerant service operations — Piercing valves and perforator cocks in 1/2" and 5/8" sizes for fast, non-invasive line access
Compressor thermal management — Universal Compressor Door for reducing shell temperature and improving efficiency in hot ambient conditions
Retrofit and field repairs — Supco controls with Quick Connect terminals for rapid installation in legacy refrigeration circuits

Supco Produk

3G Electric memasok Supco hvac equipment. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Infrared thermometer
Supco
Infrared thermometer
Mini infrared thermometer
Supco
Mini infrared thermometer
Infrared needle thermometer
Supco
Infrared needle thermometer
Thermometer and humidity
Supco
Thermometer and humidity
Differential thermometer
Supco
Differential thermometer
Thermometer and anemometer
Supco
Thermometer and anemometer

Lainnya dari Supco

Lihat semua Supco suku cadang
Supco
Supco
Axial fan motor D.350 380V THREE-PHASE
CSS-32U 32A starting module
Supco
CSS-32U 32A starting module
Supco
Supco
Axial fan motor D.350 230V single phase with square plate
Supco
Supco
Axial fan motor D.500 380V three-phase with square plate
Supco
Supco
Axial fan motor D.630 230V single-phase with square plate
Supco
Supco
Axial fan motor D.300 380V 3-PHASE
Supco
Supco
Telescopic thermometer -50..+300°C L.max:914mm
Supco
Supco
Axial fan motor D.400 230V single-phase with square plate