Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Gambar tidak tersedia
HoneywellControls

Honeywell Pressure switch DWR1 0.2/1.6 bar

Honeywell DWR1 adalah pressure switch atau pressure limiter yang dirancang khusus untuk memantau tekanan maksimum dan minimum pada sistem bahan bakar gas (sesuai DVGW Worksheet G 260), bahan bakar cair, serta sistem…

SKU 3G-CBM-04268

Juga terdaftar sebagai: HON 32306 · HON-32306

Merek
Honeywell
Item
Pressure switch DWR1 0.2/1.6 bar
Kategori
Controls
UNSPSC
39121026 — Control power transformer
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Honeywell
type
Pressure switch, pressure limiter
connection
G ½ A external thread, G ¼ internal thread
installation
Vertical or horizontal
model series
DWR
pressure range
0.2/1.6 bar
switching capacity
8 (5) A, 250 V AC

Konten Lembar Data

DWR Pressure monitors Especially suitable as a pressure monitor This pressure switch is "of special construction" or pressure limiter for fuel gases (DVGW and has been tested with 2 million operating Worksheet G 260) and liquid fuels (e.g. fuel oil), cycles. TÜV and DVGW tests exists. as well as for steam systems according to TRD 604 and hot-water systems to DIN EN12828, systems in accordance to DIN EN12952-11 and DIN EN12953-9. The DWR is used to monitor maximum and minimum pressures. SIL 2 according IEC 61508-2 DWR625 Technical data Component tested for Steam Systems according to TRD 604 Hot water Systems according to DIN EN12828 Pressure connection External thread G 1/2 (pressure gauge Fuel gases DVGW Worksheet G 260 connection) to DIN 16 288 and internal thread Pressure tank DIN EN764-7 G 1/4 to ISO 228 Part 1 (for gas applications internal thread permissible only up to 4 bar). Function Pressure monitor or pressure limiter (with external interlock) Switching device Rugged housing (200) made of seawater- Direction of action For maximum and minimum pressure monitoring resistant diecast aluminium. (DWFS, SDBFS) Materials Sensor "of special construction" by testing with 2 million cycles. Pressure bellows: Material no. 1.4571 Sensor housing: Material no. 1.4104 Switch housing: GD AI Si 12 (DIN 1725) Mounting position Product Summary Vertically upright and horizontal. Ambient temperature at switching device Type Setting range Switching Maximum Dimen- –25 to +70°C, Medium temperature –25 to +70°C. The differential working sioned maximum medium temperature at the pressure (mean values) pressure drawing sensor must not exceed the permitted ambient temperature at the switching device. Temperatures may reach 85°C for short periods. Pressure monitors without differential adjustment p. 21 + 22 Higher medium temperatures are possible DWR06 0.1…0.6 bar 0.04 bar 6 bar 1 + 15 provided the above limit values for the switching device are ensured by suitable measures DWR1 0.2…1.6 bar 0.06 bar (e.g. siphon). DWR3 0.2…2.5 bar 0.1 bar 16 bar 1 + 18 Mounting DWR6 0.5…6 bar 0.2 bar Directly on the pressure line (pressure gauge DWR625 0.5…6 bar 0.25 bar 25 bar 1 + 17 connection) or on a flat surface with two 4 mm DWR16 3…16 bar 0.5 bar Ø screws. DWR25 4…25 bar 1.0 bar 63 bar 1 + 16 Calibration DWR40 8…40 bar 1.3 bar The DWR series is calibrated for rising pressure. This means that the adjustable switching pressure on the scale corresponds to the switching point at Switching differential adjustable rising pressure. The reset point is lower by the DWR06–203 0.1…0.6 bar 0.08…0.5 bar 6 bar 1 + 15 amount of the switching differential. (See also page 17, 2. Calibration at upper switching point). DWR1–203 0.2…1.6 bar 0.15…0.6 bar In version ...-203 the switching differential is DWR3–203 0.2…2.5 bar 0.17…1.2 bar 16 bar 1 + 18 adjustable. The basic calibration is maintained. DWR6–203 0.5…6 bar 0.3…1.4 bar Bursting pressure DWR625–203 0.5…6 bar 0.4…2.5 bar 25 bar 1 + 17 For all types ≥ 100 bar, verified by TÜV test. DWR16–203 3…16 bar 0.75…3.15 bar Switching differential For values see Product DWR25–203 4…25 bar 1.3…6.0 bar 63 bar 1 + 16 Summary. DWR40–203 8…40 bar 2.3…6.6 bar Contact arrangement Single pole changeover switch. Switching 250 VAC 250 VDC 24 VDC capacity (ohm) (ind) (ohm) (ohm) Normal 8A 5A 0.3 A 8A Degree of protection IP 54 according to DIN 40 050 50 Mechanical pressure switches Tested to PE Directive 97/23/EC DBS Pressure monitors / pressure limiters In many aspects, safety-engineered pressure monitoring lines for short-circuit and line limiters offer a higher degree of safety compared break and therefore offers an additional safety with normal pressure switches and are therefore advantage – even in non-Ex-zones. For especially suitable for chemical process Ex-applications, the isolating amplifier must be engineering and thermal installations in which installed outside the Ex-zone. The lines between safety is an especially critical factor in pressure the isolating amplifier and the pressure switch monitoring. Pressure switches can also be used are monitored for short-circuit and line break. in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. SIL 2 according IEC 61508-2 DWAM6-576 The isolating amplifier is also responsible for Technical data Safety requirements for pressure limiters Pressure limiters "of special construction" (DBS) must fulfil additional safety requirements, i.e. breakage Greater safety · in process engineering and chemical or leakage in the mechanical part of the sensor must lead to shutdown to the safe side. The pressure installations, limitermust respond as if the system pressure had already exceeded the maximum limit. The control · in gas and liquid gas installations circuit for the pressure limiter must also be considered from the point of view of safety, as short-circuits Basic features: in the supply lines or other faults in the control current circuit can lead to dangerous conditions. – "Of special construction" according to VdTÜV Memorandum "Pressure 100" – Line break and short-circuit monitoring- Switching element with positive opening operation and gold-plated contacts between pressure switch and isolating The microswitch is equipped with positive opening operation. Rather than transmitting the plunger force amplifier via a spring, which is the usual method with most microswitches, this newly developed microswitch has – Suitable for Ex areas (zone 0, 1 & 2 or 20, 21 & 22) (explosion protection Ex-ia) an additional lever which transmits the movements of the pressure bellows positively to the contact lever. – Degree of protection IP 65 If the spring breaks, the contact lever is moved directly. – Plastic-coated housing (chemical version) Options: Line break and short-circuit monitoring in the control circuit – Limiter with internal interlock The resistor connected in series with the switching contact limits the current to a defined value with the Type-specific features: switch closed. In the event of short-circuit in the area between the isolating amplifier and the series – Self-monitoring sensors resistor, the current rises above the predetermined limit value, the relay of the isolating amplifier drops – Positive opening microswitches out, the output current circuit is interrupted and thus the safe condition is achieved. In the event of a line – Gold-plated contacts – TÜV, DVGW component tests break, the current flow is interrupted, the relay drops to the safe side and interrupts the output current circuit (safety sequence). Furthermore, the isolating amplifier is designed so that, if faults occur in the electronics (conductor interruption, component defect etc.) and in the resulting situations, the safe shutdown condition is assured. These characteristics of the safety-engineered isolating amplifier, including line break and short-circuit monitoring, satisfy the requirements of DIN/VDE 0660, Part 209. Connection diagram For pressure monitoring in Ex areas, the isolating amplifier must be installed outside the Ex-zone. The pressure limiter has an intrinsically safe control current circuit (Ex-ia). This arrangement is suitable for zones 0, 1 and 2, 20, 21 and 22. M e c h a n i c a l p r e s s u r e s w i t c h e s 51 Tested to PE Directive 97/23/EC Pressure switches…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Honeywell Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Honeywell DWR1 adalah pressure switch atau pressure limiter yang dirancang khusus untuk memantau tekanan maksimum dan minimum pada sistem bahan bakar gas (sesuai DVGW Worksheet G 260), bahan bakar cair, serta sistem uap (TRD 604) dan air panas (DIN EN12828). Model ini memiliki rentang tekanan 0.2/1.6 bar dengan kapasitas switching 8 (5) A, 250 V AC, dan koneksi tekanan G ½ A ulir eksternal serta G ¼ ulir internal. Sebagai pressure monitor andal dari Honeywell, produk ini telah diuji hingga 2 juta siklus operasi dan memenuhi standar SIL 2 sesuai IEC 61508-2.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa Honeywell DWR1 pressure switch digunakan?

Honeywell DWR1 digunakan sebagai pressure monitor atau pressure limiter untuk memantau tekanan maksimum dan minimum pada sistem bahan bakar gas (DVGW Worksheet G 260), bahan bakar cair, dan sistem uap/air panas. Produk ini cocok untuk aplikasi ketel uap dan pembakar industri.

Apa spesifikasi teknis Honeywell DWR1 0.2/1.6 bar?

Spesifikasi Honeywell DWR1 meliputi rentang tekanan 0.2/1.6 bar, kapasitas switching 8 (5) A pada 250 V AC, koneksi G ½ A ulir eksternal dan G ¼ ulir internal, serta suhu lingkungan -25 hingga +70°C. Produk ini telah diuji 2 juta siklus dan memenuhi SIL 2.

Bagaimana cara memasang Honeywell DWR1 pressure switch?

Honeywell DWR1 dapat dipasang secara vertikal atau horizontal. Pastikan suhu medium tidak melebihi +70°C di perangkat switching, meskipun suhu hingga 85°C diperbolehkan untuk waktu singkat. Koneksi tekanan menggunakan ulir G ½ eksternal dan G ¼ internal.

Di mana beli Honeywell DWR1 pressure switch di Indonesia?

Anda dapat membeli Honeywell DWR1 pressure switch melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi industri Anda.

Digunakan dalam

Aplikasi umum untuk Honeywell
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits

Honeywell Produk

3G Electric memasok Honeywell controls. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Honeywell
Honeywell
Pressure switch DWR16 3/16 bar
Pressure switch RT 1A 0.8/5bar
Danfoss
Pressure switch RT 1A 0.8/5bar
C 6097 A 4110 1.5-10Mbar replaces C 6097 A 2110
Honeywell
C 6097 A 4110 1.5-10Mbar replaces C 6097 A 2110
This Honeywell pressure switch is designed for industrial machine tool applications requiring liquid and corrosion resistance. It monitors pressure in hydraulic or pneumatic systems, triggering an electrical signal when pressure reaches a set point between 0.5 psi and 150 psi. The switch features a 1/8-27" MNPT pressure connection for easy installation
Honeywell
This Honeywell pressure switch is designed for industrial machine tool applications requiring liquid and corrosion resistance. It monitors pressure in hydraulic or pneumatic systems, triggering an electrical signal when pressure reaches a set point between 0.5 psi and 150 psi. The switch features a 1/8-27" MNPT pressure connection for easy installation
This Honeywell 5000 Series pressure switch is designed for machine tool applications requiring liquid and corrosion resistance. It monitors and controls pressure within a range of 0.5 psi to 150 psi. The switch features a 1/8-27" MNPT pressure connection type. Typical uses include industrial hydraulic and pneumatic systems where reliable pressure switching is needed
Honeywell
This Honeywell 5000 Series pressure switch is designed for machine tool applications requiring liquid and corrosion resistance. It monitors and controls pressure within a range of 0.5 psi to 150 psi. The switch features a 1/8-27" MNPT pressure connection type. Typical uses include industrial hydraulic and pneumatic systems where reliable pressure switching is needed
C 6097 A 4310 30-150Mbar replaces C 6097 A 2310
Honeywell
C 6097 A 4310 30-150Mbar replaces C 6097 A 2310

Lainnya dari Honeywell

Lihat semua Honeywell suku cadang
Box S4565 C 1025 V01U
Honeywell
Box S4565 C 1025 V01U
Housing S4565 A 2050 U
Honeywell
Housing S4565 A 2050 U
Housing S4565 BF 1062 U
Honeywell
Housing S4565 BF 1062 U
Honeywell
Honeywell
ST7800 A 1013 prepurge
Honeywell
Honeywell
Prepurge ST7800 A 1005
Honeywell
Honeywell
KT COMB 50 (pair of flanges)
Honeywell
Honeywell
Pressure switch DWR6 0.5/6 bar
Honeywell
Honeywell
Pressure switch DWR3 0.2/2.5 bar