ce certifiedYes
spark energy> 4 mJ (W.H.I.T.B.)
internal fuse2 A HPC (20 mm)
pre purge time1.5–50 seconds
supply voltage230 V + 10% - 15%
aps type options2 or 3 terminal or not present
humidity maximum90% RH
supply frequency50–60 Hz (± 3 Hz)
power consumption15 VA
pre ignition time1.0–50 seconds
spark gap tolerance2.5–4.5 mm
lockout type optionsvolatile or non-volatile
open circuit voltage15 kV minimum (30 pf loading)
relay contact rating1 A Inductive 0.6 pf @ 230 V ac
appliance type optionsfanned or atmospheric
certification standardEN 298:2003
flame on response time1 second max
ambient temperature range-10°C to 70°C
flame detection principleRectification
supply phase relationshipSensitive to Live and Neutral phase reversal
total maximum load current2 A
external transformer rating230 V:230 V 2 VA
number of ignition attempts1–5
minimum flame current required1 µA @ 230 V ac supply
flame detector electrode configurationDual or single probe ignition & detection

Frequently asked questions

Where can I source the Pactrol Microgas P25F FTL/V24 control in Indonesia?+

3G Electric Indonesia supplies the Pactrol Microgas P25F FTL/V24 control (PAC44030) for delivery to Jakarta and Surabaya. We handle all import logistics, Bea Cukai customs clearance, and IDR invoicing. Contact us for lead times and quotation.

What is the lead time for Pactrol Microgas P25F control delivery?+

Lead time varies based on stock availability and logistics routing. 3G Electric sources this control unit available to order with shipping to Indonesia. For your specific timeline and delivery schedule, please request a quotation — we manage all clearance and last-mile logistics.

What are the main electrical specifications of the Pactrol Microgas P25F FTL/V24?+

The Microgas P25F FTL/V24 operates on 230 V AC (±10% to −15%), 50–60 Hz (±3 Hz), with 15 VA power consumption. Spark energy exceeds 4 mJ per W.H.I.T.B. standard, internal 2 A HPC fuse (20 mm), and adjustable pre-purge/ignition times from 1.0–50 seconds. CE certified.

Enquire about Microgas P25F FTL/V24 427001/V24