Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Gambar tidak tersedia
HoneywellBurner Controls

Honeywell Relay MMI 962.23

Relay MMI 962.23 dari Honeywell adalah kontrol keselamatan otomatis untuk pembakar gas berhembus dan pembakar kombinasi, dirancang untuk mengawasi dan mengontrol pembakar industri dengan beban termal nominal apa pun…

SKU 3G-CBM-05913

Juga terdaftar sebagai: REL 25116 · REL-25116

Merek
Honeywell
Item
Relay MMI 962.23
Kategori
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Honeywell
cable entry
16 mm from below
flame detectors
Ionization probe, Infrared flicker detector IRD 1020
mounting position
any
insulation standard
IP 44

Konten Lembar Data

MMI 962.1 Gas burner automatic safety control For power gas burners Terminals for air damper motor Built-in remote reset for lock-outs Possible flame detectors: - Ionization probe - Infrared flicker detector INTRODUCTION The gas burner automatic safety control MMI 962.1 controls and monitors blown gas- and combined burners of any nominal thermal load (tested and certified according to EN 298). If an air damper unit is connected, a 2-stage operation with two fuel valves or a modulating operation with one fuel valve is possible. TECHNICAL DATA Various types and model designations differentiate the automatic safety controls with respect to the programme Operating voltage 220 / 240 V (-15... +10%) times, as well as with regard to differing national standards. 50 Hz The control box type MMI 962.1 Mod. 23 can be used Differing frequency Results in a proportional deviation of the time instead of the types MMI 812 Mod. 23 or MMI 812.1 Rating fuse max. 10 A rapid, 6 A slow Mod. 23. Power consumption 10 VA Max. load per output: - term. 3 2A, cos ϕ 0.2 - term. 4, B 2A, cos ϕ 0.4 CONSTRUCTIONAL FEATURES - term. 5, 6, C 1A, cos ϕ 0.4 total load 5A, cos ϕ 0.4 The automatic control is housed in a non-inflammable, Amplifier sensitivity 1 µA transparent, plug-in type plastic case and contains: Minimum required – Synchronous motor with speed reducer gears as the Ionization current 5 µA drive for the switching cam Flame detector cable max. 20 m cable length Air pressure monitor working contact 4 A, 230 V – Switching cam with informative programme display in Waiting time for colour malfunction remedy None – 12 times cam assembly for controlling the programme Flame detector sequence - Ionization probe – Plug-in type circuit boards with the electronic components - Infrared flicker detector IRD 1020 Weight, incl. base 350 g Mounting position any The following important indicating - and operating elements Insulation standard IP 44 are located on the front panel of the automatic control: Admissible ambient – Illuminated pushbutton for indication of malfunctions temperature for controller and reset and flame detector -20° C… +60° C – Programme display in colour Classified acc. to EN 298 BTLLXN – Screw for central mounting program timings (sec.) MMI 962.1 Model 23 Waiting time at start-up tw 8 Max. reaction time for air proving switch tlw 15 0708.20-01-e/04/99 Pre-purge time tv1 30 LK open signal tlk 38 Pre-ignition time tvz 3 Total ignition time tz 6.6 Safety time ts 3 Time delay term.6 / term.C tv2 8 1 APPLICATION TECHNOLOGY FEATURES COMMISSIONING AND SERVICE/MAINTENANCE 1. Flame Monitoring 1. Important Remarks – Before commissioning, the wiring has to be accurately The flame monitoring can be effected with the following checked. Faulty wiring can damage the unit and endanger flame detectors: the safety of the installation. – With ionization electrodes in power grids with earthed – The mains fuse has to be selected so that the limit values neutral conductor, utilizable with gas burners (interference indicated under "Technical Specifications" are under no effects of the ignition spark cannot influence the formation circumstances exceeded. Non-compliance with this of the flame signal). regulation can have very serious consequences for the – With infrared flicker detector type IRD 1020 for all types control unit and for the installation in the case of a short- of burners. (siehe Dok. 746) circuit. – For safety reasons, at least one control shut-down per 24 hours must be assured. 2. Burner Control – The control unit must be plugged-in or -out only when the mains supply has been disconnected. – The burner controls MMI 962.1 features a low-voltage – Automatic burner safety controls are safety devices and protection. If the supply voltage dropps below 160 V must not be opened. during operation, the burner switches-off. When the supply voltage raises above 180 V, the burner performs 2. Functional Check a restart independently. During commissioning and after an overhaul of the burner, – The automatic burner controls MMI only operates when the following checks have to be carried out: a) Starting test with closed manual valve and bridged gas a load is connected to terminal 5. If the fuel valve is monitor contact: interrupted by an external contact during the pre-purging – The device must go into a fault condition after the phase, a resistance of max. 22 kW, 4 Watt has to be safety period has elapsed. applied bet-ween the terminals 5 and 8. b) Close the manual valve in operating position with the gas – Functional test of the air pressure monitor before the monitor contact bridged. startup and monitoring of the air pressure during the pre- – The device must go into a fault condition after a flame purging time, as well as in the operating condition of the failure. burner. For normal applications a working contact with a c) Air pressure monitor contact interrupted: power rating of 4 A / 230 V is sufficient. – Device goes into a fault condition. – In the case of the automatic control MMI 962.1, contacts d) Bridge air pressure monitor contact before starting: can be installed between the terminals 1 and 9 (e.g., valve – Device must not start. limit position contacts). These are checked for their correct closing position when the unit is started up. The 3. Trouble Shooting connection 1-9 has to be closed during the starting Burner does not go into operation, programme indication phase of the auto-matic control. remains: – No fuel valve must be connected to terminal 6. – Electrical connection defective. – Thermostat or gas monitor "OFF". 3. Safety Burner does not go into operation, programme indication rotates continuously: With respect to design and programme sequence, the gas – Air pressure monitor defective, respectively, not in starting burner automatic safety controls of the MMI 962 type range position. (Working contact must be open). comply with the currently applicable European standards – Connection term. 1 - term. 9 interrupted and regulations. – mains voltage < 180V The automatic control switches to fault…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Honeywell Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Relay MMI 962.23 dari Honeywell adalah kontrol keselamatan otomatis untuk pembakar gas berhembus dan pembakar kombinasi, dirancang untuk mengawasi dan mengontrol pembakar industri dengan beban termal nominal apa pun. Perangkat ini mendukung detektor nyala berupa probe ionisasi atau detektor kedip inframerah IRD 1020, dengan tegangan operasi 220/240 V (-15...+10%) 50 Hz, konsumsi daya 10 VA, dan standar isolasi IP 44. Dilengkapi terminal untuk motor peredam udara, kontrol ini memungkinkan operasi dua tahap atau modulasi, serta memiliki fitur reset jarak jauh internal untuk kondisi lock-out.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi Relay MMI 962.23 Honeywell?

Relay MMI 962.23 Honeywell berfungsi sebagai kontrol keselamatan otomatis untuk pembakar gas dan pembakar kombinasi. Perangkat ini mengontrol dan memonitor urutan penyalaan, mendeteksi nyala api melalui probe ionisasi atau detektor kedip inframerah IRD 1020, serta menyediakan reset jarak jauh untuk kondisi lock-out.

Apa spesifikasi teknis Honeywell MMI 962.23?

Spesifikasi teknis Honeywell MMI 962.23 meliputi tegangan operasi 220/240 V (-15...+10%) 50 Hz, konsumsi daya 10 VA, sekring maksimal 10 A cepat atau 6 A lambat, sensitivitas amplifier 1 µA, arus ionisasi minimum 5 µA, berat 350 g, standar isolasi IP 44, dan suhu sekitar 0–60 °C.

Detektor nyala apa yang kompatibel dengan Honeywell MMI 962.23?

Honeywell MMI 962.23 kompatibel dengan probe ionisasi dan detektor kedip inframerah IRD 1020. Kabel detektor nyala maksimal 20 m. Kedua detektor ini memungkinkan kontrol yang andal untuk pembakar gas dan pembakar kombinasi di berbagai aplikasi industri.

Di mana beli Honeywell MMI 962.23 di Indonesia?

Anda dapat membeli Honeywell MMI 962.23 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda dengan aman. Hubungi kami untuk minta penawaran.

Bagaimana cara memasang Honeywell MMI 962.23?

Pemasangan Honeywell MMI 962.23 cukup sederhana: perangkat ini dipasang di posisi apa pun, dengan kabel masuk dari bawah sepanjang 16 mm. Pastikan kabel detektor nyala tidak melebihi 20 m. Gunakan sekring maksimal 10 A cepat atau 6 A lambat, dan sambungkan sesuai diagram terminal yang tertera pada housing.

Digunakan dalam

Aplikasi umum untuk Honeywell
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits

Honeywell Produk

3G Electric memasok Honeywell burner controls. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Relay MMI 813.23
Honeywell
Relay MMI 813.23
Honeywell
Honeywell
Relay MMI 816.1
MMI 811.63 relay
Honeywell
MMI 811.63 relay
Honeywell
Honeywell
Relay MMI 810.1 MOD 43
Honeywell
Honeywell
Relay MMG 811.63
Honeywell
Honeywell
Relay FFW 930

Lainnya dari Honeywell

Lihat semua Honeywell suku cadang
Honeywell
Honeywell
Relay CM 31 TW40/TS10
Relay MMI 810.13
Honeywell
Relay MMI 810.13
Honeywell
Honeywell
MMG 810.1 MOD 45 relay
Honeywell
Honeywell
Relay CM 32 PR TW30/TS5
Honeywell
Honeywell
MMI 811.35 relay
Honeywell
Honeywell
MMI 810.35 relay
Honeywell
Honeywell
Relay MMI 810.33
Honeywell
Honeywell
Relay MMI 810.40.34