Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Brahma Relay GF 2/03 - Burner Controls
BrahmaBurner Controls

Brahma Relay GF 2/03

Relay Brahma GF 2/03 adalah kontroler elektro-mekanis yang dirancang untuk mengontrol pembakar industri minyak pada aplikasi non-permanen seperti pembakar monoblok, mesin cuci bertekanan, generator udara panas, dan…

SKU 3G-CBM-05972

Juga terdaftar sebagai: REL 40106 · REL-40106

Merek
Brahma
Item
Relay GF 2/03
Kategori
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Brahma
application
oil burners (monoblock, power washers, hot air generators, steam boilers)
weight with base
240 g
fuse rating 24v 12v
10 A fast-blow
fuse rating 220v 110v
4 A fast-blow
max contacts rating 220v
6.0 A (thermostat), 2.0 A (motor), 2.0 A (ignition transformer)

Konten Lembar Data

CONTROLLERS TYPES G.. OR.. Series 03N AUTOMATIC CONTROL SYSTEMS FOR OIL BURNERS APPLICATION The electro-mechanical controllers of this series are designed to control oil burners in non-permanent applications. These controllers are suitable for : − monoblock burners − power washers − hot air generators − steam boilers − furnaces Due to the models technical and constructive features and to their variety they can be used also for the automation of cookers, and of plants employing oil burners generally, whether in domestic or industrial applications. These controllers replace integrally the 03 electro-mechanical series FEATURES Table 1 shows the main features of this series. Other important features are: − two independent safety contacts for valve driving − electrical service life at max. declared load > 250.000 operations; − Easy installation and connection. TABLE 1 Lockout due to extraneous light (2) Thermal range< 30kg/h Thermal range> 30kg/h FC7/. FC8/ photocells FC11/. FC13/.photocells Single flame Dual flame preheater (1) Pre-ignition G22 * * * * * * GF2 * * * * * GF3 * * * * * OR1 * * * * * * OR2 * * * * * OR3 * * * * * (1) Application is possible with appropriate connection (2) Function is available only in controllers with 12V and 24V supply voltage and GF2 220V and 110V 13697_r00 1/5 CONNECTION TECHNICAL DATA The connection bases type B and N can be provided to connect the external components to the controller (see Fig. Power supply : 220V 50/60Hz 2). Both bases are provided with screw terminals which Upon request: 110V 50/60Hz allow a safe and easy connection. It’s advisable to use M4 24V dc and ac 50/60Hz screw for fastening purpose. 12V dc and ac 50/60Hz Operating temperature -10°C ÷ +60°C Protection degree (with base) IP 40 Times – Pre-purge time (TV @ 20°C): 15/20 s – Safety time (TS @ 20°C): 5/10 s – Response time in case of flame failure: <1s Power consumption (@220V-50Hz): 6,5 VA (@12V/24V ): 1VA Internal Fuse – For 220V e 110V supply voltage: 6,3 A time-delay – For 24V e 12V supply voltage: 10 A time-delay External fuse – For 220V e 110V supply voltage: 4 A fast-blow – For 24V e 12V supply voltage: 10 A fast-blow Weight including connection base: about 240 g Max. contacts rating (@220V): Imax Fig.2 – Thermostat: 6,0 A cosϕ > 0,4 – Motor: 2,0 A cosϕ > 0,4 ACCESSORIES – Ignition transformer: 2,0 A cosϕ > 0,4 The following indications must be considered in order to – EV1: 0,5 A cosϕ > 0,4 choose the suitable flame detector for the controller and the application type: – EV2: 0,5 A cosϕ > 0,4 – Preheater: 0,5 A cosϕ = 1,0 Controller Type Photocell – Lockout signal: 1,0 A cosϕ = 1,0 - G22, GF2, GF3 Max. contacts rating (@12V e 24V): Imax FC8/R 1,5..5,5 lux – Thermostat: 10 A cosϕ > 0,4 Frontal side FC8/A 1,5..3,0 lux – Motor: 4,0 A cosϕ > 0,4 FC8/V 5,5.. 10 lux – Ignition transformer: 3,0 A cosϕ > 0,4 – EV1: 1,5 A cosϕ > 0,4 FC7/R 1,5..5,5 lux – EV2: 1,5 A cosϕ > 0,4 Lateral side FC7/A 1,5..3,0 lux – Lockout signal: 1,0 A cosϕ = 1,0 FC7/V 5,5…10 lux - OR1, OR2, OR3 CONSTRUCTION Frontal and lateral side FC11/R* 1,5..6,5 lux The plastic enclosure protects the controller against mechanical damage caused by crash, tempering , dust and Frontal and lateral side FC13/R 1,5..6,5 lux dirt of external ambient. An inbuilt fuse protects the FC13/A 1,5..3,0 lux controller internal relays in case of short circuit on the outputs (valves, fan and lockout signal); * The FC11/R is provided with a black plastic enclosure only The suffix indicates the colour of the photocell enclosure: /R red OVERALL DIMENSIONS /A blue Fig1 shows the controller overall dimensions /V green FC7 FC8 drilling plane FC13 drilling plane FC11 drilling plane Base type dimensions h B 99 N 98.3 Fig.1 Fig. 3 Fig. 4 2/5 13697_r00 The figures (Fig.3) show the types and fixing systems of CHECKING AT START the available flame detectors. Before any ignition attempt make sure that the combustion 4 mm diameter screws are suggested To fix the flame chamber is free from oil, then make sure that: detector. − if the starting attempt occurs with the flame detector Core hitches and Strain relieves can be fitted on the sides obscured the controller performs a lockout at the end of of the controllers enclosures and the connecting bases. safety time; These accessories can be supplied upon request (see − if start up attempt occurs with extraneous light, the Fig.5). controller proceeds to lockout within the time equivalent to safety time (only in versions where this option is available) ; − when the flame detector is obscured in running position the oil valve(s) is/are de-energized within 1 second, and the controller goes to lockout after a recycle; The intervention of regulators, limiters or safety devices causes a shut down of the controller according to the Fig.5 application type; − Operating times and cycle are in compliance with the INSTALLATION DIRECTIONS ones declared for the used controller type. − The controllers are safety devices; guarantee and responsibility of the manufacturer will be debarred if the products are tempered with by the user;. OPERATION − Make sure that a regulation shutdown occurs every 24 Once the thermostats are closed, the controller energizes hours to allow the controller self-checking its efficiency the burner motor; in this phase the device proceeds to a (non permanent operation systems). self-checking process of the flame detection and safety − The controller must be connected and disconnected circuit. At the end of pre-purge time the output of the first oil without power supply. valve is powered. If flame is detected, at the end of safety − The controller can be mounted in any position. time, the controller de-energizes the ignition transformer − Avoid exposure to dripping water. and goes to running position. − A ventilated installation ambient and a quite low At the end of safety time, in the double stage controllers, temperature ensure the longest life of the controller…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Brahma Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Relay Brahma GF 2/03 adalah kontroler elektro-mekanis yang dirancang untuk mengontrol pembakar industri minyak pada aplikasi non-permanen seperti pembakar monoblok, mesin cuci bertekanan, generator udara panas, dan ketel uap. Produk ini memiliki berat 240 g dengan basis, konsumsi daya 6,5 VA pada 220V-50Hz, dan dilengkapi dua kontak pengaman independen untuk penggerak katup. Relay ini tersedia dalam tegangan suplai 220V, 110V, 24V DC/AC, dan 12V DC/AC, dengan rating kontak maksimum 6,0 A (termostat), 2,0 A (motor), dan 2,0 A (transformator pengapian) pada 220V.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa Brahma GF 2/03 digunakan?

Brahma GF 2/03 digunakan untuk mengontrol pembakar industri minyak pada aplikasi seperti pembakar monoblok, mesin cuci bertekanan, generator udara panas, dan ketel uap. Produk ini cocok untuk aplikasi non-permanen di sektor domestik maupun industri.

Apa spesifikasi teknis Brahma GF 2/03?

Spesifikasi Brahma GF 2/03 meliputi berat 240 g dengan basis, konsumsi daya 6,5 VA pada 220V-50Hz, tegangan suplai 220V/110V/24V DC-AC/12V DC-AC, rating kontak maksimum 6,0 A (termostat), 2,0 A (motor), dan 2,0 A (transformator pengapian) pada 220V. Waktu pengamanan (TS) 5/10 detik dan waktu prepurge (TV) 15/20 detik pada 20°C.

Di mana beli Brahma GF 2/03 di Indonesia?

Anda dapat membeli Brahma GF 2/03 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan pengiriman tepat waktu ke lokasi industri Anda.

Bagaimana cara memilih Brahma GF 2/03 yang tepat?

Pilih Brahma GF 2/03 berdasarkan tegangan suplai yang sesuai dengan sistem Anda: 220V, 110V, 24V DC/AC, atau 12V DC/AC. Pastikan aplikasi Anda termasuk dalam kategori non-permanen seperti pembakar monoblok atau ketel uap. Periksa juga rating kontak maksimum 6,0 A untuk termostat dan 2,0 A untuk motor serta transformator pengapian.

Apa keunggulan Brahma GF 2/03 dibandingkan seri sebelumnya?

Brahma GF 2/03 menggantikan seri elektro-mekanis 03 sebelumnya secara integral. Keunggulannya meliputi dua kontak pengaman independen untuk penggerak katup, umur listrik lebih dari 250.000 operasi pada beban maksimum, serta pemasangan dan koneksi yang mudah dengan basis tipe B atau N.

Digunakan dalam

Aplikasi umum untuk Brahma
Italian light-oil burner ignition — T11 transformer as scheduled-maintenance replacement
Heavy-duty industrial burner racks — T15 / T18 / T36 for high-spark-energy applications
Combustion control-card swaps — CM31N / CM32N / CM391 onto existing Brahma-equipped burners
UV flame-detection retrofits — upgrading older photocell-based detection to solid-state UV
Safety-relay scheduled replacement — SRE / SM / FDB series on commercial gas / oil burners

Brahma Produk

3G Electric memasok Brahma burner controls. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Brahma
Brahma
Relay GR2
Brahma
Brahma
Relay GR1 10.10
Relay G22/Z S10
Brahma
Relay G22/Z S10
Relay CM 11F
Brahma
Relay CM 11F
Relay G 22 S10 220V
Brahma
Relay G 22 S10 220V
Relay CM 11
Brahma
Relay CM 11

Lainnya dari Brahma

Lihat semua Brahma suku cadang
Relay MM 192.4 TW5/TS10
Brahma
Relay MM 192.4 TW5/TS10
Relay G 22 S03N TV15/TS10
Brahma
Relay G 22 S03N TV15/TS10
Relay CM 31 F TW10/TS5
Brahma
Relay CM 31 F TW10/TS5
Relay RE3 SP
Brahma
Relay RE3 SP
Relay CM 31 TW30/TS10
Brahma
Relay CM 31 TW30/TS10
Brahma
Brahma
FC 7/R cell
Brahma
Brahma
Relay GE 733
Brahma
Brahma
Relay GE 735