Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Gambar tidak tersedia
SatronicBurner Controls

Satronic Relay G22 S09

Relay G22 S09 dari Satronic adalah kontrol pembakar otomatis untuk sistem pembakaran minyak (oil burner) non-permanen, dirancang untuk aplikasi seperti pembakar monoblok, ketel uap, dan generator udara panas. Kontrol…

SKU 3G-CBM-05975

Juga terdaftar sebagai: REL 40109 · REL-40109

Merek
Satronic
Item
Relay G22 S09
Kategori
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Satronic
external fuse rating
4.0 A fast
internal fuse rating
6.3 A slow blow
max heat input 30kg h
ignition safety time 10 seconds
max heat input 100kg h
ignition safety time 5 seconds

Konten Lembar Data

EURO-OIL SERIES TYPE G22 series 09 AUTOMATIC OIL BURNER CONTROL APPLICATION SYSTEMS This range of electronic oil burner controls has been specifically designed for oil burners for non permanent operation. The automatic burner controls of this series are suitable for: − monobloc oil burners − warm air generators − steam boilers − power washers − kilns Due to the technical and structural characteristics and to the variety of models they can be used for the automation of cookers and oil burner operated appliances for domestic and industrial applications. FEATURES The G22 series 09 oil burner controls, simple wiring and installation. The main features of this series are following: − for non permanent operation; − for one-stage oil burners (single flame); − prearranged for appliances with pre-heater (see “CONNECTION DIAGRAMS”); − maximum heat input according to the European standard EN 267:1999-09: - ≤ 30 kg/h (max. ignition safety time 10 seconds) - > 30 ≤ 100 kg/h (max. ignition safety time 5 seconds) the pre-purge time has to be set in compliance with nominal fuel throughput of the burner; − in accordance with the European standard DIN EN 230:1991-05 concerning monobloc oil burners, safety control and regulation devices. The DIN registration number relevant to this series of devices is the following: 5F165/04 − in compliance with the standard DIN 4794 part 2, edition December 1980 regarding warm air generators WLE (only version with TV = 20s and TS = 5s); − operation with flame detector type FC7/FC8; − two independent safety contacts for oil valve(s) control; − electrical service life at max load >250.000 operations; − simple wiring and installation. 5779_r00 1/4 TECHNICAL DATA and reliable connection. To fix the socket it is advisable to Supply Voltage: 220/240V 50/60Hz use screws type M4. To fix the control to the socket use the on request: 110/120V 50/60Hz pin supplied with the control box. Operating temperature range: -20°C +60°C Ambient humidity: 95% max at 40°C Protection degree: IP 40 Times - Pre-purge time (TV) 1,5/10/20/30/40 s - Ignition safety time (TS) 5/10 s - Dropout time on running flame failure: < 1s The times given on the burner control label correspond to the values guaranteed. The actual values slightly differ from the values given, as prepurge time can be longer and safety time shorter than their nominal values. Power consumption: 8 VA Contact rating: I max - Thermostat: 6.0 A cosϕ > 0,4 - Motor: 2.0 A cosϕ > 0,4 - Ignition transformer: 2.0 A cosϕ > 0,4 - EV1: 0.5 A cosϕ > 0,4 - EV2: 0.5 A cosϕ > 0,4 - Pre-heater: 0.5 A cosϕ = 1,0 - Alarm: 1.0 A cosϕ = 1,0 Internal fuse rating: 6.3 A slow blow External fuse rating: 4.0 A fast Weight (including socket): 132 g Fig.2 CONTROLS FOR SPECIAL APPLICATIONS On request it is possible to meet special requirements For the electrical connection of the external devices see concerning times and operating cycles. “CONNECTION DIAGRAMS”. CONSTRUCTION ACCESSORIES The particular construction and the use of the surface The following data are useful to choose the most suitable mounted components allow to have reduced overall flame detector for the appliance and the control box used: dimensions. • for traditional burners (yellow flame burners) the The enclosure made of plastic material protects the control following photocells are suitable: from possible damages resulting from crashes, incautious FC8/R 1,5..5,5 lux opening, dust and contact with the external environment. frontal side FC8/A 1,5..3,0 lux A varistor protects the control from voltage transients on the FC8/V 3,0..5,5 lux electric network. An inbuilt fuse protects the internal relays of the control box FC7/R 1,5..5,5 lux in case of short circuit on the outputs (valves, ignition lateral side FC7/A 1,5..3,0 lux transformer, motor and lockout signal). FC7/V 3,0..5,5 lux The suffix indicates the colour of the photocell enclosure: OVERALL DIMENSIONS /R red The following figure (Fig.1) shows the overall dimensions of /A blue the control. /V green Drilling plane FC7 FC8 FC8 FC7 Fig.3 Fig.1 CONNECTION The figures (Fig.3) show the types and fixing systems of the For the connection of the external components the control available flame detectors. box is delivered with socket type N (see Fig. 2). The socket is To fix the flame detector screws diameter 4 are suggested. provided with a screw terminal board which allows a simple 2/4 5779_r00 Cable holders and core hitches can be fitted on the sides of OPERATION the enclosure and the connecting sockets. These At every start the control unit supplies the burner motor and accessories can be supplied upon request (see Fig.4). the ignition transformer and proceeds to a self-checking of its own components. During the pre-purge time TV the internal circuit makes a test of the flame signal amplifier circuit. Extraneous light or a fault in the amplifier cause the lockout of the control within 10 seconds. At the end of pre-purge time the oil valve output is supplied; if a flame signal is detected at the end of safety time, the control unit deenergizes the Fig.4 ignition transformer and goes to running position. If no flame signal is detected during safety time, the control goes to DIRECTIONS FOR USE lockout, the control outputs of the valve, the ignition transformer and the burner motor are switched off while the − Automatic controls are safety devices and must not be lockout signal output is supplied. The controls prearranged opened. The manufacturer’s responsibility and guarantee are invalidated if the control is incautiously opened. for the use of an oil pre-heater supply the pre-heater when the room thermostat and/or the boiler one switch off. In this − For safety reasons a regulation shutdown must occur way the starting sequence begins. The thermostat opening every 24 hours (systems for non permanent operation). causes the repetition of the starting sequence after the − The control has to be connected and disconnected only heating stage (RISC) of the pre-heater. The attached without the mains power. diagrams are useful to understand how each control − The control can be mounted in any position. operates. − Avoid exposing the control unit to dripping water. − Ventilation and the lowest temperature ensure the Abnormal operation - Extraneous light longest life of the control. All control boxes of this series perform a lockout within 10 − Make sure that the type (code and times) you are using is seconds. correct before installing or replacing the control. RESET OF THE CONTROL ELECTRICAL INSTALLATION When a control has gone to lockout, a delay of 5 seconds − The applicable national and European standards (e.g. EN should be considered before attempting to reset the control 60335-1/EN 50165) regarding electrical safety must be unit; if this time is not observed the control may not reset. respected. − Phase and Neutral should be connected correctly; a TESTING THE FLAME SIGNAL mistake could cause a dangerous situation, as the It is extremely important to test the flame signal level before internal safety devices can be ineffective in case the having the burner operate. connecting wires of thermostats and valves are not Arrange one cable connected to terminal…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Satronic Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Relay G22 S09 dari Satronic adalah kontrol pembakar otomatis untuk sistem pembakaran minyak (oil burner) non-permanen, dirancang untuk aplikasi seperti pembakar monoblok, ketel uap, dan generator udara panas. Kontrol ini mendukung operasi satu tahap (single flame) dengan kapasitas panas maksimum sesuai standar EN 267:1999-09, yaitu ≤ 30 kg/jam dengan waktu pengamanan penyalaan 10 detik, dan > 30 hingga ≤ 100 kg/jam dengan waktu pengamanan penyalaan 5 detik. Dilengkapi dengan dua kontak pengaman independen untuk katup minyak, tegangan suplai 220/240V 50/60Hz, serta sekring eksternal 4.0 A fast dan internal 6.3 A slow blow. Produk ini merupakan suku cadang pembakar yang umum dicari untuk peralatan industri di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa Relay G22 S09 Satronic digunakan?

Relay G22 S09 dari Satronic digunakan sebagai kontrol pembakar otomatis untuk sistem pembakaran minyak non-permanen. Produk ini cocok untuk pembakar monoblok satu tahap (single flame), ketel uap, generator udara panas, dan mesin cuci bertekanan tinggi. Kontrol ini bekerja dengan detektor nyala api tipe FC7/FC8 dan memiliki kapasitas panas maksimum hingga 100 kg/jam.

Apa spesifikasi teknis Relay G22 S09 Satronic?

Spesifikasi teknis Relay G22 S09 meliputi tegangan suplai 220/240V 50/60Hz (tersedia juga 110/120V 50/60Hz), sekring eksternal 4.0 A fast, sekring internal 6.3 A slow blow, dan kapasitas panas maksimum ≤ 30 kg/jam (waktu pengamanan penyalaan 10 detik) atau > 30 hingga ≤ 100 kg/jam (waktu pengamanan penyalaan 5 detik). Produk ini sesuai standar DIN EN 230 dan EN 267.

Bagaimana cara memilih Relay G22 S09 yang tepat untuk pembakar minyak?

Pilih Relay G22 S09 Satronic berdasarkan kapasitas panas pembakar Anda. Jika laju aliran bahan bakar ≤ 30 kg/jam, gunakan pengaturan waktu pengamanan penyalaan 10 detik. Jika antara >30 hingga 100 kg/jam, gunakan pengaturan 5 detik. Pastikan tegangan suplai sesuai (220/240V atau 110/120V) dan gunakan detektor nyala api tipe FC7/FC8. Periksa juga sekring eksternal 4.0 A fast dan internal 6.3 A slow blow.

Di mana beli Relay G22 S09 Satronic di Indonesia?

Anda dapat membeli Relay G22 S09 Satronic melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan suku cadang pembakar ini sampai ke lokasi industri Anda. Hubungi kami untuk minta penawaran.

Digunakan dalam

Aplikasi umum untuk Satronic
Steam boiler systems — Satronic MZ770S photocell and ZT870 transformer for flame detection and ignition control.
Industrial gas furnaces — Satronic IRD820 infrared photocell and control modules for continuous flame supervision during high-temperature processes.
Oil and gas burner retrofit — Satronic replacement photocell connectors and transformers for upgrading legacy burner safety systems.
Commercial heating equipment — Satronic burner control assemblies in air heaters and unit heaters for building HVAC systems.
Process heater automation — Satronic flame-fail relays and photocell harnesses in thermal-oil and hot-water heating loops.
Preventive maintenance programs — Satronic spare-parts kits stocked for scheduled photocell and transformer replacement in high-availability industrial facilities.

Satronic Produk

3G Electric memasok Satronic burner controls. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Satronic
Satronic
Relay GF2 S10
Satronic
Satronic
Relay CM391.2 10.5
Satronic
Satronic
Relay TF 844
Satronic
Satronic
Relay SM 152.2
Satronic
Satronic
Relay TF 974
Satronic
Satronic
Relay LME 41 054C2

Lainnya dari Satronic

Lihat semua Satronic suku cadang
Satronic
Satronic
Relay CM 391-2 Frisquet
High sensitivity UV bulb
Satronic
High sensitivity UV bulb
Satronic
Satronic
IRD 1020 cell axial blue (oil and gas)
Relay RMO 8853 C2
Satronic
Relay RMO 8853 C2
Satronic
Satronic
Relay DMG 970-N MOD.03
Satronic
Satronic
Relay SM 592.2 TW1.5/TS5
Satronic
Satronic
Relay CM 381N.4 TW5/TS5
Satronic
Satronic
Relay MG569-BWZG (replaces 568 SE)