Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

DUNGS MB-D(LE) 407-412 B07, One-stage mode, Integrated bypass valve - Gas multibloc
DungsGas multibloc

DUNGS MB-D(LE) 407-412 B07, One-stage mode, Integrated bypass valve

DUNGS GasMultiBloc® MB-D(LE) 407-412 B07 adalah gas multibloc yang mengintegrasikan filter, regulator, dua katup pengaman, dan katup bypass dalam satu unit kompak. Produk ini dirancang untuk aplikasi pembakar…

SKU 3G-OTH-02922

Juga terdaftar sebagai: MBDLE407412B07 · MB DLE 407 412 B07

Merek
Dungs
Item
MB-D
Kategori
Gas multibloc
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Konten Lembar Data

[{"filename":"mb-dle-407-412-b07_datasheet_en_215195.pdf","text":"GasMultiBloc®\n Combined regulator and\n safety shut-off valves\n Single-stage function\n Integrated bypass valve\n\n MB-D(LE) 407 - 412 B07\n\n 7.22\n\n\n\n\n Technical description The modular system permits individual\n The DUNGS GasMultiBloc® integrates filter, solutions by using an internal bypass valve\n regulator, valves and pressure switches in in connection with separately controlled\n one compact fitting. valves, by adding a valve proving system,\n mini/maxi pressure switches, pressure limit-\n - Dirt trap unit: Fine-mesh sieve ers, limit switches at valve V2.\n - One regulator, two main valves and one\n bypass valve: B07 Application\n - Two valves are fast opening, one valve The modular system permits individual\n is slow opening solutions in gas safety and regulator engi-\n - Solenoid valves up to 360 mbar (36 kPa) neering. Suitable for gases of families 1, 2,\n as per DIN EN 161 Class A Group 2 3 and other neutral gaseous media.\n - Sensitive setting of output pressure by\n proportional regulator as per DIN EN 88 Approvals\n Class A Group 2 EU type testing certificate as per:\n - High flow rates with low pressure drop • EU-Gas Appliances Regulation\n - DC solenoid drive interference degree N • EU-Pressure Equipment Directive\n - Main volume restrictor at valve V2, by- Approvals in other important gas consum-\n pass restrictor at valve V3 ing countries.\n\n\n\n Edition 03.19 • Nr. 215 195\n - Hydraulic opening delay\n - Flange connections with pipe threads as\n per ISO 7/1\n - Simple mounting, compact, light-\n weight\n\n1…6\n\fSpecifications\n\nNominal diameters MB-…407 B07 MB-…410/412 B07\nFlange with pipe threads as per Rp 1/2, 3/4 Rp 3/4, 1, 1 1/4\nISO 7/1 (DIN 2999) and their combinations and their combinations\n\nMax. operating pressure 360 mbar (36 kPa)\n\nOutput pressure ranges MB-… S22 pa: 4 mbar (0.4 kPa) to 20 mbar (2 kPa)\n MB-… S52 pa: 4 mbar (0.4 kPa) to 50 mbar (5 kPa)\n\nMedia Gases of families 1, 2, 3 and other neutral gaseous media\n\nAmbient temperature -15 °C to +70 °C (Do not operate MB-D below 0 °C in liquid gas systems. Only suit-\n able for gaseous liquid gas, liquid hydrocarbons destroy sealing materials.)\n\nDirt trap Fine-mesh sieve. Replacement only possible by dismounting the fitting.\n\nPressure switches Types GW A5, GW A2, NB A2, ÜB A2 mountable as per DIN EN 1854.\n For further information, refer to Datasheet GW A2 No. 215 183 and Datasheet\n GW A5 No. 225 901.\n\nPressure regulator Pressure regulator compensated for residual pressure, leakproof seal when\n switched off by means of valve V1 as per DIN EN 88 Class A. Setpoint spring\n permanently installed (no spring exchange possible). A vent line above roof is\n not required. Internal pulse tap provided.\n\nSolenoid valve V1 Valve as per DIN EN 161 Class A Group 2, fast closing, fast opening\n\nSolenoid valve V2 Valve as per DIN EN 161 Class A Group 2\n Valve V2 design\t\t Main volume restrictor\n MB fast closing fast opening without\n MB-D fast closing fast opening with\n MB-DLE fast closing slow opening with\n MB-LE fast closing slow opening without\n\nSolenoid valve V3 (bypass) Valve as per DIN EN 161 Class A Group 2, with volume restrictor\n\nMeasuring/ignition gas connection For G 1/8 as per DIN ISO 228, refer to Pressure taps on page 4\n\nBurner pressure monitor pBr Connection downstream of valve V2, pressure switch mountable on adapter laterally\n\nVoltage / frequency 50-60 Hz ,220 - 230 V AC, -15% +10%\n\n\nElectrical connection Plug connection as per DIN EN 175301-803\n for valves and pressure switches\n\nRating/power consumption Refer on page 4\nSwitch-on duration 100%\nDegree of protection IP 54 as per IEC 529 (EN 60529)\nRadio interference Interference degree N\n\nMaterials of gas conveying parts Housing\t\t\t aluminium die casting\n Diaphragms, seals\t\t NBR basis, Silopren (silicone rubber)\n Solenoid drive\t\t\t steel, brass, aluminium\n\nInstallation position Solenoid vertically upright or lying horizontally as well as its intermediate posi-\n tions.\n\nClosed position signal contact Closed position signal contact, type K01/1 (DIN-tested), mountable on V2\n\n\n\n\n 2…6\n\f Equipment variants\n GasMultiBloc®...B07 407 B07 410 B07 412 B07\n Single-stage function\n MB • • •\n MB-D • • •\n MB-DLE • • •\n MB-LE • • •\n Microfilter (standard) with sieve • • •\n Gas pressure switch\n downstream of filter • • •\n downstream of valve V2 on adapter • • •\n Pressure regulator • • •\n Valve V1, double seat • • •\n Valve V2, single seat – • –\n Valve V2, double seat • – •\n Valve V3, single seat with restrictor • • •\n Valve opening separately • • • S...2 version\n Flange \t\t Rp 1/2 • – –\n \t\t\t Rp 3/4 • • • • = possible\n \t\t\t Rp 1 – • • (•) = on request\n \t\t\t Rp 1 1/4 – • • - = not possible\n\n\n MB-...B07 version\n\n V1 = Valve 1 4 V3\n V2 = Valve 2\n V3 = Valve 3\n 3 = Filter 3\n 4 = Pressure switch, optional 1\n 5 = Regulator V1 5 V2\n\n\n Mounting of VPS 504 valve proving system possible\n Mounting of K01/1 closed position signal contact possible\n\n\n Type key of MultiBloc®\n\n\n\n\n 0 = common\n 2 = separated\n\n\n 2 = 4 - 20 mbar up to 360 mbar\n 5 = 4 - 50 mbar up to 360 mbar\n\n\n\n\n 1 = two A valves for main gas + regulator\n 7 = two A valves for main gas, one A valve together\n with V1 as internal bypass around V2 + regulator\n\n\n\n\n 403 = DN 10, V2 = Single-seat valve\n 405 = DN 15, V2 = Single-seat valve\n 407 = DN 20, V2 = Double-seat valve\n 410 = DN 25, V2 = Single-seat valve\n 412 = DN 32, V2 = Double-seat valve\n 415 = DN 40, V2 = Double-seat valve\n 420 = DN 50, V2 = Double-seat valve\n\n\n without = (MB or MB-ZR)\n -D = Main volume restrictor\n -LE = adjustable opening behaviour\n -DLE = D + LE combination\n\n without = single stage\n ZR = double-stage with partial volume setting\n first stage\n\n\n\n3…6\n\fDimensions [mm]\n\n\n\n\n f\n e\n h\n\n\n\n\n d\n\n c = Space requirement for cover of pressure switch a\n f = Space requirement for exchanging the solenoid g\n c b\n\n\nType…

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Dungs Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

DUNGS GasMultiBloc® MB-D(LE) 407-412 B07 adalah gas multibloc yang mengintegrasikan filter, regulator, dua katup pengaman, dan katup bypass dalam satu unit kompak. Produk ini dirancang untuk aplikasi pembakar industri satu tahap (single-stage) dengan katup bypass internal, tekanan operasi maksimal 360 mbar (36 kPa), dan rentang tekanan output 4 mbar hingga 20 mbar (S22) atau 4 mbar hingga 50 mbar (S52). Cocok untuk gas keluarga 1, 2, 3, dan media gas netral lainnya, gas multibloc ini menawarkan solusi modular untuk sistem pengaman dan regulasi gas.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi DUNGS GasMultiBloc MB-D(LE) 407-412 B07?

DUNGS GasMultiBloc MB-D(LE) 407-412 B07 berfungsi sebagai unit kombinasi regulator tekanan dan katup pengaman gas untuk pembakar industri satu tahap. Produk ini mengintegrasikan saringan, regulator proporsional, dua katup solenoida, dan katup bypass internal dalam satu bodi kompak, memastikan aliran gas stabil dan aman sesuai standar DIN EN 161 dan DIN EN 88 Kelas A Grup 2.

Apa spesifikasi teknis DUNGS MB-D(LE) 407-412 B07?

Spesifikasi teknis meliputi tekanan operasi maksimal 360 mbar (36 kPa), rentang tekanan output 4 mbar hingga 20 mbar (tipe S22) atau 4 mbar hingga 50 mbar (tipe S52), suhu lingkungan -15 °C hingga +70 °C, dan sambungan flens dengan ulir pipa sesuai ISO 7/1. Katup solenoida tersedia untuk tegangan DC dengan derajat interferensi N.

Di mana beli DUNGS GasMultiBloc MB-D(LE) 407-412 B07 di Indonesia?

Anda dapat membeli DUNGS GasMultiBloc MB-D(LE) 407-412 B07 melalui 3G Electric, distributor resmi yang memasok peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk pengiriman ke berbagai wilayah di Indonesia. Hubungi kami untuk minta penawaran dan informasi ketersediaan produk.

Bagaimana cara memilih DUNGS GasMultiBloc yang tepat untuk aplikasi saya?

Pemilihan DUNGS GasMultiBloc tergantung pada tekanan operasi, rentang tekanan output yang dibutuhkan, dan diameter nominal. Untuk MB-D(LE) 407-412 B07, tersedia diameter nominal Rp 1/2 hingga Rp 1 1/4. Pastikan tekanan output sesuai dengan kebutuhan pembakar Anda, misalnya tipe S22 untuk 4-20 mbar atau S52 untuk 4-50 mbar.

Apa keunggulan DUNGS GasMultiBloc dibandingkan unit terpisah?

Keunggulan utama DUNGS GasMultiBloc adalah desain kompak yang mengintegrasikan filter, regulator, dua katup pengaman, dan katup bypass dalam satu unit. Ini mengurangi kebutuhan ruang pemasangan, menyederhanakan perpipaan, dan menurunkan potensi kebocoran. Produk ini juga ringan dan mudah dipasang, serta mendukung solusi modular dengan aksesori seperti sakelar tekanan mini/maksi.

Digunakan dalam

Aplikasi umum untuk Dungs
Industrial steam boilers — MB-ZRDLE MultiBloc on modulating gas-fired plant
Hospital and hotel plant rooms — MB-D series for two-stage commercial burners
Food-industry ovens and dryers — DMV butterfly valves on high-turndown modulating lines
Petrochemical gas-train skid assemblies — FRS / FRSBV regulators with GW pressure switches
Retrofit drop-in replacements for older Dungs MB assemblies on existing Weishaupt / Riello burners

Dungs Produk

3G Electric memasok Dungs gas multibloc. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
DUNGS MB-D(LE) 403 B01, One-stage mode
Dungs
DUNGS MB-D(LE) 403 B01, One-stage mode
DUNGS MB-ZRD(LE) 405-412 B01, Two-stage function
Dungs
DUNGS MB-ZRD(LE) 405-412 B01, Two-stage function
DUNGS MBC-300/700/1200-SE/N, safety shut-off valves
Dungs
DUNGS MBC-300/700/1200-SE/N, safety shut-off valves
DUNGS MBC-65/120..., One-stage mode
Dungs
DUNGS MBC-65/120..., One-stage mode
DUNGS MB-VEF 415-425 B01, Gas-air-ratio control
Dungs
DUNGS MB-VEF 415-425 B01, Gas-air-ratio control
Valve MBLE 410 B01 S22
Dungs
Valve MBLE 410 B01 S22

Lainnya dari Dungs

Lihat semua Dungs suku cadang
DUNGS MB-VEF 407-412 B01, Gas-air-ratio control
Dungs
DUNGS MB-VEF 407-412 B01, Gas-air-ratio control
DUNGS MB-ZRD(LE) 407-412 B07, Integrated bypass valve
Dungs
DUNGS MB-ZRD(LE) 407-412 B07, Integrated bypass valve
DUNGS MB-ZRD(LE) 415-420 B01, Two-stage function
Dungs
DUNGS MB-ZRD(LE) 415-420 B01, Two-stage function
DUNGS MBC-...-VEF, Infinitely variable air/gas ratio control mode
Dungs
DUNGS MBC-...-VEF, Infinitely variable air/gas ratio control mode
DUNGS MBC-...-SE, Combined servo pressure regulator and safety shut-off valves
Dungs
DUNGS MBC-...-SE, Combined servo pressure regulator and safety shut-off valves
DUNGS MB-D(LE) 405-412 B01, One-stage mode
Dungs
DUNGS MB-D(LE) 405-412 B01, One-stage mode
DUNGS MB-D(LE) 415-420 B01, One-stage mode
Dungs
DUNGS MB-D(LE) 415-420 B01, One-stage mode
DUNGS MBC-WND - DUNGS WhirlWind System®
Dungs
DUNGS MBC-WND - DUNGS WhirlWind System®