We ship to Indonesia — door-to-door, customs and logistics handled by 3G Electric

DUNGS MB-ZRD(LE) 407-412 B07, Integrated bypass valve - Gas multibloc
DungsGas multibloc

DUNGS MB-ZRD(LE) 407-412 B07, Integrated bypass valve

Dungs GasMultiBloc® MB-ZRD(LE) 407-412 B07 adalah gas multibloc yang mengintegrasikan filter, regulator, dan katup pengaman dalam satu unit kompak. Produk ini dilengkapi katup bypass internal (B07) dan tersedia dalam…

SKU 3G-OTH-02927

Also listed as: MBZRDLE407412B07 · MB ZRDLE 407 412 B07

Brand
Dungs
Item
MB-ZRD
Category
Gas multibloc
Available to Order
Ready stock & customs handled
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Ships to: Jakarta, Surabaya, Bandung, Medan, Batam
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Indonesia

Phone
+65 8878 8355

Datasheet Content

[{"filename":"mb-zrdle-407-412-b07_datasheet_en_215196.pdf","text":"GasMultiBloc®\n Combined regulator and\n safety shut-off valves\n Two-stage function\n Integrated bypass valve\n\n MB-ZRD(LE) 407 - 412 B07\n\n 7.25\n\n\n\n\n Technical description The modular system permits individual\n The DUNGS GasMultiBloc® integrates filter, solutions by using an internal bypass valve\n regulator, valves and pressure switches in in connection with separately controlled\n one compact fitting. valves, by adding a valve proving system,\n mini/maxi pressure switches, pressure limit-\n - Dirt trap: Fine-mesh sieve ers, limit switches at valve V2.\n - One regulator, two main valves and one\n bypass valve: B07 Application\n - Two single-stage valves, one two-stage The modular system permits individual\n valve solutions in gas safety and regulator engi-\n - Two valves are fast opening, one valve neering. Suitable for gases of families 1, 2,\n is slow opening 3 and other neutral gaseous media.\n - Solenoid valves up to 360 mbar (36 kPa)\n as per DIN EN 161 Class A Group 2 Approvals\n - Sensitive setting of output pressure by EU type testing certificate as per:\n proportional regulator as per DIN EN 88 • EU-Gas Appliances Regulation\n Class A Group 2 • EU-Pressure Equipment Directive\n - High flow rates with low pressure drop Approvals in other important gas consum-\n - DC solenoid drive interference degree N ing countries.\n\n\n\n Edition 01.21 • Nr. 215 196\n - Main volume restrictor at valve V2, by-\n pass restrictor at valve V3\n - Hydraulic opening delay\n - Flange connections with pipe threads as\n per ISO 7/1\n - Simple mounting\n1…6 - Compact, light-weight\n\fSpecifications\n\nNominal diameters MB-…407 B07 MB-…410/412 B07\nFlange with pipe threads as per Rp 1/2, 3/4 Rp 3/4, 1, 1 1/4\nISO 7/1 (DIN 2999) and their combinations and their combinations\n\nMax. operating pressure 360 mbar (36 kPa)\n\nOutput pressure ranges MB-… S22 pa: 4 mbar (0.4 kPa) to 20 mbar (2 kPa)\n MB-… S52 pa: 4 mbar (0.4 kPa) to 50 mbar (5 kPa)\n\nMedia Gases of families 1, 2, 3 and other neutral gaseous media.\n\nAmbient temperature -15 °C to +70 °C (Do not operate MB-D below 0 °C in liquid gas systems.\n Only suitable for gaseous liquid gas, liquid hydrocarbons destroy sealing ma-\n terials.)\n\nDirt trap Fine-mesh sieve. Replacement only possible by dismounting the fitting.\n\nPressure switches Types GW A5, GW A2, NB A2, ÜB A2 mountable as per DIN EN 1854.\n For further information, refer to Datasheet GW A2 No. 215 183 and Datasheet\n GW A5 No. 225 901.\n\nPressure regulator Pressure regulator compensated for residual pressure, leakproof seal when switched off by\n means of valve V1 as per DIN EN 88 Class A. Setpoint spring permanently installed (no spring\n exchange possible). A vent line above roof is not required. Internal pulse tap provided.\n\nSolenoid valve V1 Valve as per DIN EN 161 Class A Group 2, fast closing, fast opening\n\nSolenoid valve V2 Valve as per DIN EN 161 Class A Group 2, fast closing\n Valve V2 design Main volume restrictor Partial volume restrictor\n MB-ZRD fast opening with with\n MB-ZRDLE slow opening with with\n MB-ZRLE slow opening with without\n\n\nSolenoid valve V3 (bypass) Valve as per DIN EN 161 Class A Group 2, with volume restrictor\n\nMeasuring/ignition gas connection For G 1/8 as per DIN ISO 228, refer to Pressure taps on page 4\n\nBurner pressure monitor pBr Connection downstream of valve V2, pressure switch mountable on adapter laterally\n\nVoltage / Frequency 50-60 Hz 220-230 V AC, -15 % +10 %\n\n\nElectrical connection Plug connection as per DIN EN 175301-803\n for valves and pressure switches\n\nRating/power consumption Refer on page 4\nSwitch-on duration 100 %\nDegree of protection IP 54 as per IEC 529 (EN 60529)\nRadio interference Interference degree N\n\nMaterials of gas conveying parts Housing\t\t aluminium die casting\n Diaphragms, seals NBR basis, Silopren (silicone rubber)\n Solenoid drive\t\t steel, brass, aluminium\n\nInstallation position Solenoid vertically upright or lying horizontally as well as its intermediate posi-\n tions.\n\nClosed position signal contact Closed position signal contact, type K01/1 (DIN-tested), mountable to V2\n\n\n\n\n 2…6\n\f Equipment variants\n GasMultiBloc®...B07 407 B07 410 B07 412 B07\n Two-stage function\n MB-ZRD • • •\n MB-ZRDLE • • •\n MB-ZRLE • • •\n Microfilter (standard) with sieve • • •\n Gas pressure switch\n downstream of filter • • •\n downstream of valve V2 on adapter • • •\n Pressure regulator • • •\n Valve V1, double seat • • •\n Valve V2, single seat – • –\n Valve V2, double seat • – •\n Valve V3, single seat with restrictor • • •\n Valve opening separately • • • S...2 version\n Flange Rp 1/2 • – –\n \t\t\t Rp 3/4 • • • • = possible\n \t\t\t Rp 1 – • • (•) = on request\n \t\t\t Rp 1 1/4 – • • – = not possible\n\n\n\n MB-...B07 version\n\n V1 = Valve 1\n V2 = Valve 2\n V3 = Valve 3\n 4 = Filter\n 5 = Pressure switch, optional\n 6 = Regulator\n\n\n Mounting of VPS 504 valve proving system possible\n Mounting of K01/1 closed position signal contact possible\n\n\n Type key of MultiBloc®\n\n\n\n\n 0 = common\n 2 = separated\n\n\n 2 = 4 - 20 mbar up to 360 mbar\n 5 = 4 - 50 mbar up to 360 mbar\n\n\n\n\n 1 = two A valves for main gas + regulator\n 7 = two A valves for main gas, one A valve together\n with V1 as internal bypass around V2 + regulator\n\n\n\n\n 403 = DN 10, V2 = Single-seat valve\n 405 = DN 15, V2 = Single-seat valve\n 407 = DN 20, V2 = Double-seat valve\n 410 = DN 25, V2 = Single-seat valve\n 412 = DN 32, V2 = Double-seat valve\n 415 = DN 40, V2 = Double-seat valve\n 420 = DN 50, V2 = Double-seat valve\n\n\n -D = Main volume restrictor\n -LE = adjustable opening behaviour\n -DLE = D + LE combination\n\n\n without = single stage\n ZR = double-stage with partial volume setting\n first stage\n\n\n3…6\n\f Dimensions [mm]\n\n\n\n\n f\n e\n\n\n h\n\n\n\n\n d\n c\n g a\n c = Space requirement for cover of pressure switch\n f = Space requirement for exchanging the solenoid b\n\n\nTyp Nominal rating [VA] Dimensions [mm] Weight\n ~(AC) 230 V; +20°C…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dungs Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Dungs GasMultiBloc® MB-ZRD(LE) 407-412 B07 adalah gas multibloc yang mengintegrasikan filter, regulator, dan katup pengaman dalam satu unit kompak. Produk ini dilengkapi katup bypass internal (B07) dan tersedia dalam varian diameter nominal Rp 1/2, 3/4, 1, dan 1 1/4. Dirancang untuk tekanan operasi maksimal 360 mbar (36 kPa) dan rentang tekanan output 4 mbar hingga 50 mbar, gas multibloc ini cocok untuk gas keluarga 1, 2, 3, dan media gas netral lainnya. Sebagai distributor resmi, 3G Electric menyediakan gas multibloc Dungs untuk kebutuhan pembakar industri Anda di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Frequently Asked Questions

Apa fungsi DUNGS MB-ZRD(LE) 407-412 B07?

DUNGS MB-ZRD(LE) 407-412 B07 adalah gas multibloc yang mengintegrasikan filter, regulator tekanan, dan dua katup pengaman utama serta satu katup bypass internal (B07) dalam satu unit. Fungsinya mengatur dan mengamankan aliran gas pada pembakar industri, dengan dua katup buka cepat dan satu katup buka lambat untuk pengaturan dua tahap.

Apa spesifikasi teknis DUNGS MB-ZRD(LE) 407-412 B07?

Spesifikasi teknis meliputi tekanan operasi maksimal 360 mbar (36 kPa), rentang tekanan output 4 mbar hingga 50 mbar (tergantung varian S22 atau S52), diameter nominal Rp 1/2 hingga 1 1/4, dan katup solenoida sesuai DIN EN 161 Kelas A Grup 2. Media gas yang cocok adalah gas keluarga 1, 2, 3, dan media gas netral lainnya.

Di mana beli DUNGS MB-ZRD(LE) 407-412 B07 di Indonesia?

Anda dapat membeli DUNGS MB-ZRD(LE) 407-412 B07 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan gas multibloc ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi proyek Anda. Hubungi kami untuk minta penawaran.

Apa keunggulan DUNGS GasMultiBloc dibandingkan katup gas biasa?

Keunggulan DUNGS GasMultiBloc adalah integrasi filter, regulator, dan katup pengaman dalam satu unit kompak, menghemat ruang pemasangan. Dilengkapi katup bypass internal (B07) untuk penyesuaian aliran, katup solenoida hingga 360 mbar, dan regulator proporsional sesuai DIN EN 88 Kelas A Grup 2 untuk pengaturan tekanan output yang sensitif.

Bagaimana cara memilih DUNGS MB-ZRD(LE) 407-412 B07 yang tepat?

Pilih berdasarkan diameter nominal (Rp 1/2, 3/4, 1, atau 1 1/4) yang sesuai dengan pipa gas Anda, rentang tekanan output (S22: 4-20 mbar atau S52: 4-50 mbar), dan tekanan operasi maksimal 360 mbar. Pastikan media gas yang digunakan termasuk keluarga 1, 2, 3, atau gas netral. Konsultasikan dengan tim teknis 3G Electric untuk rekomendasi yang tepat.

Used in

Common applications for Dungs
Industrial steam boilers — MB-ZRDLE MultiBloc on modulating gas-fired plant
Hospital and hotel plant rooms — MB-D series for two-stage commercial burners
Food-industry ovens and dryers — DMV butterfly valves on high-turndown modulating lines
Petrochemical gas-train skid assemblies — FRS / FRSBV regulators with GW pressure switches
Retrofit drop-in replacements for older Dungs MB assemblies on existing Weishaupt / Riello burners

Dungs Products

3G Electric supplies Dungs gas multibloc. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
DUNGS MB-D(LE) 407-412 B07, One-stage mode, Integrated bypass valve
Dungs
DUNGS MB-D(LE) 407-412 B07, One-stage mode, Integrated bypass valve
DUNGS MB-ZRD(LE) 405-412 B01, Two-stage function
Dungs
DUNGS MB-ZRD(LE) 405-412 B01, Two-stage function
DUNGS MB-D(LE) 403 B01, One-stage mode
Dungs
DUNGS MB-D(LE) 403 B01, One-stage mode
Valve MBLE 410 B01 S22
Dungs
Valve MBLE 410 B01 S22
Valve MBDLE 415 B01.S52
Dungs
Valve MBDLE 415 B01.S52
Valve MBDLE 407 B01.S20
Dungs
Valve MBDLE 407 B01.S20

More from Dungs

View all Dungs parts
DUNGS MB-VEF 407-412 B01, Gas-air-ratio control
Dungs
DUNGS MB-VEF 407-412 B01, Gas-air-ratio control
DUNGS MB-ZRD(LE) 415-420 B01, Two-stage function
Dungs
DUNGS MB-ZRD(LE) 415-420 B01, Two-stage function
DUNGS MBC-...-VEF, Infinitely variable air/gas ratio control mode
Dungs
DUNGS MBC-...-VEF, Infinitely variable air/gas ratio control mode
DUNGS MBC-...-SE, Combined servo pressure regulator and safety shut-off valves
Dungs
DUNGS MBC-...-SE, Combined servo pressure regulator and safety shut-off valves
DUNGS MB-D(LE) 405-412 B01, One-stage mode
Dungs
DUNGS MB-D(LE) 405-412 B01, One-stage mode
DUNGS MB-D(LE) 415-420 B01, One-stage mode
Dungs
DUNGS MB-D(LE) 415-420 B01, One-stage mode
DUNGS MBC-WND - DUNGS WhirlWind System®
Dungs
DUNGS MBC-WND - DUNGS WhirlWind System®
DUNGS MBC-300/700/1200-SE/N, safety shut-off valves
Dungs
DUNGS MBC-300/700/1200-SE/N, safety shut-off valves